What We Do At THE TECH SHOP Charge Rate $40.00 hr Labor automatic $20.00 inspection charge cash only upfront.Anti Virus removal w/new free program called PC Tools andCleaning of Hard Drive $30.00 Rebuild PC's PC Upgrade's Internet Interfacing Buying & Selling Electronic'sLaptop'sDesktop'sTV'sHome Stereo'sVCR'sDVD Player'sVideo's Game's Car Stereo's>>["Must Be In The Factory Box"]

Address 7735 Hixon Rd Apt B, Minocqua, WI 54548
Phone (715) 446-4333
Website Link
Hours

fanuc 086 error Hazelhurst, Wisconsin

Reply With Quote 04-06-2012,06:56 PM #2 dandrummerman21 View Profile View Forum Posts Cast Iron Join Date Feb 2008 Location MI, USA Posts 444 Post Thanks / Like Likes (Given) 21 Likes Powered by vBulletin Version 4.2.2 Copyright © 2016 vBulletin Solutions, Inc. You may need to edit the parameters if you are using the standard tape.FANUC O RS232 SETTINGS1. Double checked params and didn't see anything obvious.

I will make sure the connectors make good contact to minimise a comms outage. And confirm that AlphaCam can be set for software handshake. Help grow and collaborate one of the largest CNC alarm listing databases for Machinists, Maintenance, CNC Programmers, CNC hobby and DIY CNC guys. JD5B = I/O chanel 2 and 3 you can change the connector JD5 To JD5B.

Forum New Posts FAQ Calendar Forum Actions Mark Forums Read Quick Links Today's Posts View Site Leaders Thanks / Like Statistics Hottest Threads / Posts Forum Manufacturing Today CNC Machining Fanuc Thanks Chris Reply With Quote 06-05-2013,02:50 AM #2 angelw View Profile View Forum Posts Registered Join Date Sep 2010 Posts 1192 Originally Posted by cbsr2003 I bought a used Hardinge Cobra All rights reserved From my experience you get this when you do not have a cable (or good cable) plugged into the control.

Several functions may not work. SG 7 - Signal Ground CD 8 I Carrier Detect:Signal must be straped to DTR. I've seen it more often on the female side(go figure). All Rights reserved.

Also tried setting EasyDNC to port scan and get the same almost immediate "086" alrm when we hit output. First thing checked was the mem lock. Engines Musical Instrument Design and Construction Jet Engines and Ram Jets Parts for Radio Control Models RC Robotics and Autonomous Robots Steam Engines Stirling Engines International Forum Brazilian CNCzone Spanish CNCzone The blinking lsk shows up as the program is loading and will normally quit when the loading is done but I'm not sure if the blinking quits after an 086 alarm.

Back to top #4 JParis Posted 04 June 2007 - 09:45 AM JParis Merchant of Death Moderators 25,971 posts quote:086 I/O Device Problem on RS232. Following is the cable configuration for Xon Xoff Handshaking. A guy from machine electric is coming to replace it or configure the other port wed, until then I will try and keep troubleshooting the problem. Reply With Quote 01-28-2006,01:23 PM #11 darrylh View Profile View Forum Posts View Gallery Uploads Registered Join Date Dec 2004 Location UK Posts 26 Downloads0 Uploads0 Thanks 'Spark-el' for the very

They download fine but get the 086 alarm on upload... OK 1HomeContactUsWhatWeDoWhatItCostsExperienceWebsite Designed at Homestead Get a Website and List Your Business « Fanuc P+CANCEL | Main | Makino MC-65 APC » Fanuc Alarm 086 by Mark Hartless on 01/03/15 Alarm Casting Metals Moldmaking Welding Brazing Soldering Sealing Mass finishing equipment/media/stratigies 80/20 TSLOTS / Other Aluminum Framing Systems Commercial Products Support Forums Automation Technology Products Taiwan How-Mau Machinery Co., Ltd Zapp Automation This problem is not emanating from the the computer end unless its DTR line is being used to assert pin 6 of the control.

Once registered and logged in, you will be able to create topics, post replies to existing threads, give reputation to your fellow members, get your own private messenger, post status updates, When trying to upload DNC, I press the input key and LSK flashes momentarily and an 086 alarm appears on the monitor. I have tested the cable, tried another cable, even tried another PC that runs other mills with both cables. All CNCzone.com Content - Copyright © 2014 - All Rights Reserved CNC Machines,CAD/CAD,Milling Machines,Lathes,Classifieds, Lasers,Engraving,woodworking,MetalWorking Our Brands
Register for free Login E-Mail / Username Password Login E-Mail / Username Password

Is it a setting I have to compare with the particular fanuc controller and its settings? Regards, Bill Loopback Null Modem Pin Out Machine Side ---------------------------------- PC Side DB25 Male Connector ---------------- DB9 Female ------ DB25 Female 1 ---- Shield Trace ----------------Not Connected ---- Not Connected 2 The loop back comes comes about by connecting pins 6 and 8 at the control end to the DTR pin (20) at the control end. Hold eob key simultaneously with output start while starting download of cnc parameters to get option paras.

HTH Back to top #13 endicottmachine Posted 21 June 2007 - 11:07 AM endicottmachine Member Members 61 posts the cable tested good. The Loopback Handshaking gives the illusion of full Handshaking, when in fact there is no Handshaking at all. All the posts I've seen about this issue seem to result in fixing broken cables. At the same time press EOB and Output Start this will now copy across the Parameters including all the 900 option parameters > Copyright © 2016 Pennine Automation Spares Ltd.

Also if anyone knows which parameters to check the rest of the rs232 setting I would appreciate it. HTML and other scripts/tags will be rejected. With control powered up release the E-Stop, In parameters check ISO=1 and 552=10 2. Check to see that you are making good connection, sometimes over time and lots of use the male pins on the cable will push their individual female counter parts in a

Register today. Reply With Quote 01-19-2006,07:19 PM #2 Al_The_Man View Profile View Forum Posts View Gallery Uploads Community Moderator Join Date Dec 2003 Location Canada Posts 21774 Downloads0 Uploads0 The Data ready signal You may have to register before you can post: click the register link above to proceed. If you can punch and not read, I don't think it's the cable.

Best, Darryl Reply With Quote 01-28-2006,06:47 PM #12 spark-el View Profile View Forum Posts View Gallery Uploads Registered Join Date Jan 2006 Location usa Posts 39 Downloads0 Uploads0 On your memory Practical Machinist is the easiest way to learn new techniques, get answers quickly and discuss common challenges with your peers. Reply With Quote 01-21-2006,02:49 PM #3 darrylh View Profile View Forum Posts View Gallery Uploads Registered Join Date Dec 2004 Location UK Posts 26 Downloads0 Uploads0 Hello Al, Thanks for this. how do I go change the settings too 4 on the memory card reply Comment viewing options Flat list - collapsedFlat list - expandedThreaded list - collapsedThreaded list - expanded Date

When the file is being sent it flashes "input" I would do a loop test thru the cable and see if the cable puked on ya. CNC, Mechatronics Integration and Custom Machine Design Logic will get you from A to B. The only thing that happened of any significance was the PC getting unplugged by accident. Back to top #7 within a thou Posted 04 June 2007 - 11:10 AM within a thou Advanced Member Members 1,275 posts The LSK is the machine waiting for the info

I have checked all fuses on the back of machine, in case some type of power issue was the cause. Wont transmit either way Reply With Quote 04-06-2012,07:22 PM #4 angelw View Profile View Forum Posts Titanium Join Date Sep 2010 Location Victoria Australia Posts 2,596 Post Thanks / Like Likes DR signal off. Newly Posted Classifieds Listings CNCWiki Articles CNCzone Club House General Off Topic Discussions Machinist Hangout Facebook Group Discussion Australia, New Zealand Club house Norwegian Club House South Africa Club House Canadian

Mill: YCM 1040A Control: Fanuc MXP 100i Thanks. Any help would be appreciated. jumpered out as I mentioned.