Computer Repair, web design, computer upgrades, virus removal, computer security, computer classes, troubleshooting, free estimates, back up and recovery, data recovery and more. If it's technology, it's JNM 1- Always Offer Excellent Service 2- Treat Each and Every Customer As If They Were Our Only Customers 3- Help the Community Every Chance We Get 4- Express Respect and Love to Everyone Whether It Is A Customer, Prospect, or Visitor 5- Always make everything right, if someone is dissatisfied, we will make it right! At JNM PC Experts, the customer comes first. We are always on the lookout for more ways of providing you with excellent service. This is the reason we have created many technical support venues and created our 'house calls' (onsite service) but don't take our word for it, listen to our customers. We are also on Angieslist.com and have many other websites that have our customer testimonials including but not limited to, Facebook, Thumbtack, and Merchant Circle. Call us today for the expert computer repair service you deserve.

JNM values all of our customers and will give 110% to you! JNM was created on five core values and remains to operate on these values. Full Service Expert Computer Repair Services for Home and Business We Offer The Following Services and Much More: * Virus Removal * Computer Tune-Ups

Address 427 W Pike St Ste 301, Clarksburg, WV 26301
Phone (304) 931-4270
Website Link http://www.jnmpcexpert.com
Hours

frm 41211 integration error ssl Shinnston, West Virginia

Responder normanescobar dijo: enero 21, 2013 en 9:27 pm hola Macufendo. FRM-41211: integration error SSL failure running another productAnd user can not print the report, This error is coming with all users. Thanx & Regards, Raja Goto: Reply-Top of page If you think this item violates copyrights, please click here Subject: Re: FRM-41211:Integration error:SSL failure running another product Author: Hans Van Driel, Netherlands Not the answer you're looking for?

Sa7ar It How do I solve the error '41211 integration error ssl failure running another product'? Why don't Mistborn and Mistings get drunk/poisoned because of the alcohol? Lo mismo me ocurrió con un servidor Terminal Server en Windows 2008 R2 los usuarios no podían ejecutar reportes y pensamos que era incompatibilidad con el sistema operativo, sin embargo, el We just use individual program units (or when-button-pressed) triggers in various forms to run their corresponding report.

Why is the spacesuit design so strange in Sunshine? Any other tips or solutions for this error would be very much appreciated. Previously, when I need to run a set of reports, I programmed them individually in the library, each with a different procedure run_report_xxx01, run_report_xxx02...etc.. Introduce tus datos o haz clic en un icono para iniciar sesión: Correo electrónico (necesario) (La dirección no se hará pública) Nombre (necesario) Web Estás comentando usando tu cuenta de WordPress.com.

Can I call report from my desktop based form using web.document() if yes then how. Is accuracy binary? Workaround for Bug 267128: -------------------------- Use commmode of SYNCHRONOUS if executing RUN_PRODUCT more than once per session. Action: Check the RUN_PRODUCT built-in.

Then it prints the report. I suspected that's the reason because when I debug the form, this error does not occur. Comment Submit Your Comment By clicking you are agreeing to Experts Exchange's Terms of Use. This bug occurs when you issue a second ASYNCHRONOUS RUN_PRODUCT call to run a report, before the first report has completed.

I want to call report from form but the error above raised in oracle 10g, how to solve it ? An important note also is that Forms 6i is no longer supported by Oracle - nor is it supported to run on Windows Server 2008 64-bit. Printer Already Installed. DanRollins -- EE database cleanup volunteer 0 LVL 6 Overall: Level 6 Oracle Database 3 Message Expert Comment by:Mindphaser2002-07-01 I posted a separate question for Henka in this TA. **

You can not post a blank message. BASHYAM RAJA Oct 21, 2003, 07:54 Raja, There can be several causes. I need help on this same issue. I don't see any obvious flaws in your method 2, but if that consistently causes the FRM-41211 error, I think you will have to avoid or change that method. 0 Write

Apr 6, 2015 P J Sudharshan · PDPM Indian Institute of Information Technology, Design and Manufacturing Jabalpur This can occur for a number of reasons. With this method, I do not hit any problem. Pero ahora ni esto sirve . Report message to a moderator Re: FRM-41211: integration error SSL failure running another product [message #550717 is a reply to message #550663] Wed, 11 April 2012 17:46 owais_baba

Desafortunadamente el enlace provisto parece no existir mas. For example, if you want to get multiple reports based on the number of check boxes checked in the form, you should execute RUN_PRODUCT in SYNCHRONOUS mode. Solution:========================1) Use SYNCHRONOUS instead of ASYNCHRONOUS when running multiplereports. NOTE: LAN INSTALLATION IS NO LONGER SUPPORTED WITH ORACLE DEVELOPER. 7) Last Cause may be .....

But, it's not a good way to program, because I need to keep changing/ adding if there's a change in requirement. Luego de visitar un par de páginas encuentro, este link  FORO DE ORAClE que me llevo a este otro enlace EXTERNO donde nos regalan dos DLL, para ser más exactos: NN60.dll destroy_parameter_list.... Thank you veyr much for your help :) 0 LVL 6 Overall: Level 6 Oracle Database 3 Message Expert Comment by:Mindphaser2002-06-07 Please update and finalize this old, open question.

So, I changed the reports to method 2 and now hit the FRM-41211 error. If so, creating a timer in the WHEN-BUTTON trigger and writing a WHEN-TIMER-EXPIRED trigger that counted the number of tries (using a global variable) and tried to do the RUN_PRODUCT might Oracle introduced in version 11g release 2 a new feature called Advanced Compression which is not covered here. Below are a number of Causes and Solutions Cause no 1)========================== Cause of this error may be......"Report Server" property of "Reports" object is not set.

Sign up today to join our community of over 10+ million scientific professionals. Hemos solucionado el problema reconstruyendo los perfiles del usuario en la red. Join Now For immediate help use Live now! The Oracle documentation states (Note:23837.1 or refer to the Oracle Forms Designer/Builder On-Line Help) : FRM-41211: Integration error: SSL failure running another product.

CONTINUE READING Suggested Solutions Title # Comments Views Activity Password Hashing vs Encryption for long term viability 3 66 69d SQL Query 6 50 61d Oracle 12c 10 80 23d Copy Get 1:1 Help Now Advertise Here Enjoyed your answer? Both will delete data from table, but what is the difference between these below statements truncate table ?? This is not efficient as when I gradually add new reports, I need to add new procedures (eg: run_report_xxxnew) and recompile the library and also related forms which referenced to it.

Add_Parameter(pl_id,'DESNAME',TEXT_PARAMETER,RTRIM(:bloque.DESTINO||r_archivo_pdf||'.PDF')); Run_Product(REPORTS,'xxxxxx.rep', SYNCHRONOUS, BATCH ,FILESYSTEM, pl_name, NULL); .........................Valora esta respuesta0Comentar RE:Error: FRM-41211: Integration error: SSLPublicado por Edgar(1 intervención) el 31/05/2007 21:22:34Dure varias semans con el mismo problema: tuve que desintalar completamente However, what makes me wonder is, previously, before I change the program to loop a table to obtain the report_id, this procedure works ok. From there I am running a form that calls a report. Higher level in brake fluid tank after pad replacement Is Karma different for accidental killing than intentional killing?

Starting with a precise definition, along with clear business goals, is essential. This could be either set in "Report Server" property of the "Reports" object during design time (in Forms Builder), or could be programaticaly set using SET_REPORT_OBJECT_PROPERTY built-in similar to following : Why did my electrician put metal plates wherever the stud is drilled through? Am I correct?

Responder normanescobar dijo: octubre 11, 2011 en 8:07 am Gracias por comentar. LOOP 1..1000) Solution Explanation: ===================== This bug does NOT affect all situations in which RUN_PRODUCT is used to call Oracle Reports from Oracle Forms. users last 24h5Act. Promoted by Experts Exchange Engage with tech pros in our community with native advertising, as a Vendor Expert, and more.

Yes, the disadvantage is that the form is locked and the user has to wait until the report finishes before the user can continue in the form (or run another report). If running this in a SYNCHRONOUS mode, means, the PDF report will need to wait for the printer report to complete before being executed? Solution:======================== Verify that the REPORTS60_PATH is set correctly.The REPORTS60_PATH should point to a directory which containsthe executable files (for example,.rdf or .rep files) that areused by Oracle Forms to run the Por favor, vuelve a intentarlo Lo sentimos, tu blog no puede compartir entradas por correo electrónico.

Technical questions like the one you've just found usually get answered within 48 hours on ResearchGate. Problem Explanation: This bug does NOT affect all situations in which RUN_PRODUCT is used to call Oracle Reports from Oracle Forms. Featured Post Looking for New Ways to Advertise?