found an uncorrectable media error Red Jacket West Virginia

Address 25806 US Highway 119 N, Belfry, KY 41514
Phone (606) 519-4901
Website Link
Hours

found an uncorrectable media error Red Jacket, West Virginia

When a Patrol Read or a Rebuild operation encounters a media error on the source drive, it punctures a block on the target drive to prevent the use of the data Suggested Solutions Title # Comments Views Activity Windows 10 clean install on a new hard drive 10 57 49d WordPress: is there a reboot option in the Admin panel? 9 90 View: New Articles|All Articles Home|Reviews|Forums|Articles|My Profile About Overclock.net | Join the Community |Advertise|Contact Us|All Staff MobileDesktop © 2016Enthusiast Inc. Fire up the MegaRAID utility to get more info on which disk it is.

More... "...Dell is committed to delivering on the promise to execute ideas and key changes wherever possible, and to stay accountable for taking the feedback seriously. " Tell them funky dudes. In a simple windows system I would look to fix the registry, but this is a raid setup. #3 Dec 24, 2013 Share martygale 7Posts 0Likes That's indicating for supplying me with this case for review. Silent Base 600 - Red by Duality92 › AmazonBasics High-Speed HDMI Cable - 3 Feet (Latest Standard) by TheCautiousOne › Microsoft Internet Keyboard PS/2 by Mingan › Cherry MX 6.0 Keyboard

System halted". Join Now For immediate help use Live now! So if we look back at the very first day when John's server lost one drive the status of the drives are like this: Drive 0 : Failed Drive 1 : I'll explain later at the end.) Anyways, this morning the RAID controller (down at a research lab I used to work at) sent an e-mail saying: Code: Controller ID: 0 Patrol

Put drive 0 on slot 1, drive 1 on slot 2 and, drive 2 on slot 0. If there's anything I left out, let me know. References  Dell article on "How to fix a RAID puncture?" Dell article on "Double Faults and Punctures in RAID arrays" Dell article on "Logical Layers vs Physical Layers of RAID arrays" To run a Slow (or Full) Initialization, see Installation and User's Guide for IBM ServeRAID-M Software - Chapter 5 for "Manage Virtual Drives Initialization".

If the volume has redundancy (e.g. When a VD with cached data goes offline or missing during runtime, the cache for the VD is discarded. When John realizes that one of the drive in slot 0 is bad he quickly grabs a new one and put it in, without bothering about the state of other disks.  I intend to do that after the New Year Holiday, because since this event I have been getting random errors in Sierra Charts, but only in one installed copy (I have

So, when one of the disks is replaced, the regenerated block, during the rebuild is corrupted because there is not enough information to generate a good block. (invalid parity and RAID To make the task more manageable, test all the drives you can at the same time. Called Dell Thailand Support yesterday for NBD on-site warranty support. Yes, my password is: Forgot your password?

Bummer. Back up the data on the drives before any changes are made to the configuration. I did suggest to at least upgrade it to Windows Server, but my principle investigator said it was working good enough, so we let it be... Missed getting the notification of your reply.

Solved OMSM : Patrol Read found an uncorrectable media error.: Physical Disk 1:0:7 Controller 0, Connector 1 Posted on 2015-02-02 Server Hardware IT Administration Storage Hardware 1 Verified Solution 5 Comments In order to submit a comment to this post, please copy this code and paste it along with your comment: 74bb7150b028e8fb3e0f027d6a981dbf Posts Implementation of tree data structure in Python Mellanox IB Although, I didn't see A:2:17 report as online like the other two. Also for the HDs, I know enterprise grade is what I should go for, but I think they were ~$100 more a drive.

The crappy Dell computer we are using seemed sufficient at the time. All rights reserved. Thereafter existing files are not recognised by Sierra Charts, so chart won't load. it's not RAID level 0), you'll need to replace the bad disk and rebuild the volume.

I googled everywhere for clear explanations but I still had some questions left. Join & Ask a Question Need Help in Real-Time? In my log, I'm seeing a lot of these errors: Code: ID = 589 SEQUENCE NUMBER = 85085 TIME = 03-05-2014 05:20:27 LOCALIZED MESSAGE = Controller ID: 0 Patrol Read corrected Is something locking up? #2 Dec 24, 2013 Share justrading 2,287Posts 188Likes Quote from mgookin: Where are you getting these error messages?

Step: 6 Let the background initialization finishes and then analyze the controller logs to verify that there are no medium errors distributed across multiple hard drives on the same logical block. MegaRAID Command Line Interface (MegaCLI) You can recover/clear the punctured block area of a virtual drive. Resolution ( need Nikhil to verify ) (1) check the logs (2) run VD consistency check (3) replace all affected disk(s) (4) run the VD consistency check and the badblocks (5) info on these drives: A:2:0 A:2:16 A:2:17 It appears the drives eventually came "online" from being "failed" and "bad".

Step: 4 Once the initialization completes clear the configuration again and create a RAID 5 with three hard drives and do a full initialization as explained in above step. Zum Beispiel, in Nachricht Nr. 1 in den Ereignismeldungen Tabelle "% s" wird von der Firmware-Version, die von der Firmware gelesen wird ersetzt, wenn das Ereignis generiert wird. In most of the LSI* based controller whenever one disk fails from a container (Virtual Disk), the controller marked that virtual disk as degraded. At one point they wanted to configure RAID from scratch, and initialise the C drive.

http://en.community.dell.com/support-forums/servers/f/906/t/19407608 Are there any further details in the OpenManage about the individual physical disks? 0 Message Author Comment by:Geoff Millikan2015-02-03 That thread shows the array was throwing a lot of I stopped them, refused to allow that to happen, kept at it until they finally configured just the new drive. What should I do? OMSM : Patrol Read found an uncorrectable media error.: Physical Disk 1:0:7 Controller 0, Connector 1 Name PERC 5/i Integrated State Ready Firmware Version 5.2.2-0072 Driver Do you have any suggestions?

Posted by admin on Sep 17, 2013 in RAID | 1 comment What is a puncture stripe or a punctured RAID array and how to recover from it?  To understand the He was relying on the tech in the call centre to give him directions, and I was finding out stuff from the net faster using my iPad than they were figuring Once he received the new drive he yanked the bad hard drive out and put the new drive in. Code: ID = 3060 SEQUENCE NUMBER = 93234 TIME = 05-07-2014 20:19:24 LOCALIZED MESSAGE = Controller ID: 0 State change: PD = Port A:2:0 Previous = Rebuild Current = Online --

However, I'd really prefer to find an alternative solution.