As the go-to electricians in Bluefield, WV, Hylton's Electric Connection is every home and business owner's answer to reliable electrical services. From home electrical wiring to installing commercial fire alarm systems, the team uses their valuable experience to keep your property safe and efficient. They proudly serve clients in West Virginia, Virginia, and Tennessee, and no problem is too big or too small for their staff. Hylton's Electric Connection first opened for business 25 years ago, and they knew they had to stand out from every other electric company in the area. They hired the best contractors and invested in routine in-house training to keep them at the top of their game. Each team member is either an apprentice, journeyman, or master electrician, and many have also achieved additional certifications, including DSC-certified installer, BICSI-registered technician, and Valcom-certified designer. With a wide range of abilities and expertise, Hylton's Electric Connection meets every clients' needs. Their long list of services includes both residential and commercial electrical installation and maintenance. They keep homes and businesses operating smoothly and install features to maximize efficiency. Power generators, security systems, and video surveillance systems are also available for every type of property. They'll even come to your home for smaller tasks, including generator repair and wireless networking. The detail-oriented work and affordable rates from Hylton's Electric Connection keep the lights on in Bluefield, WV, and they're ready to tackle your electric-related projects today. Call them at (304) 325-3101 to schedule an appointment with a certified electrician. You'll also find a long list of references on their website.

Electrical Contractor, Commercial, Residential, Industrial: Installations, Wiring Computer and Phone Cabling, Fiber Optics, Cabling, Generators, Stand By Systems, Industrial Wiring, Fire Alarm Systems, Security Access Systems, Burglar Alarm Systems, Motor Control Systems, 24 HR Emergency Service, VA 27050505657A WV 012861

Address 574 Chapelview Rd, Bluefield, WV 24701
Phone (304) 325-3101
Website Link http://www.hyltonelectric.com
Hours

event id 11 controller error source disk Bud, West Virginia

Here's a thought: I am getting the impression though I'm not yet certain of it, that "indexing" of drives is being put on each drive instead of all under C:\program files This took care of the errors in Event Viewer. One of the last few times the message was generated, we got the following events also. my perception is that this has been a long term failure in the management of the Microsoft development process, or to phrase it another way, nobody has a clue WTF is

Please replace Cache board. Also running a near identical machine with BESR that we put together just for testing, and this issue doesn't occur there. Any chance these errors occur when the drive goes into suspend mode? 0 LVL 2 Overall: Level 2 Message Expert Comment by:rupeshsaini2010-07-01 it may happen just disable it and So, if you insert a memory stick for the first time, it could be logged as Harddisk1\DR1 but when you eject it and put it back in, it will be Harddisk1\DR2

m 0 l Can't find your answer ? Artikel-ID: SLN167235 Datum der letzten Änderung: 07/14/2015 10:21 AM Diesen Artikel bewerten Präzise Nützlich Leicht verständlich War dieser Artikel hilfreich? Every driver we can find on the system is now up to date. 0 Message Author Comment by:Jsmply2010-07-02 Spoke with Seagate support today. Wow the identical machine does not do it eh.

Problem is in Windows IMHO. I will check the registry this evening when the machine is not in use. If ten years ago it was still common to see an entire company using just one server, these days that's no longer the case. If BESR truly has the drive in use, would that cause the error?

how to fix it? 0 Pimiento OP itischarles2 Jan 16, 2015 at 10:11 UTC 1st Post This link might help.http://support.microsoft.com/kb/159865How to Distinguish a Physical Disk Device from an In other words the sort of thing Microsoft and Dell and it's hardware driver makers keep to themselves, should have to be doing, but likely won't unless this were a bug What I have found: http://social.technet.microsoft.com/Forums/en-US/itprovistasecurity/thread/4d7d110c-c82a-40b7-812a-821e5c0da2c1 0 Message Author Comment by:Jsmply2010-07-02 Tried running Process Explorer already. I'm considering doing some more deep tests with tools like HDDScan (hddscan.com).

I use DISKPART: CMD > DISKPART list disk 0 Pimiento OP slacka Feb 3, 2014 at 5:57 UTC 1st Post I just read all of the answers, even They had us change the sleep setting to never. Even with 5 minutes per server (to check the logs and other parameters), it may take an hour to make sure that everything is ok and no "red lights" are blinking Um no.

It either happens when safely removing (but here is the kicker, not ALWAYS). Starting to seem awfully similar to that xp paging error stupidity. I would doubt mobo replacement too. Well, you'd be both safe, functioning, but also have those log events that you see, right?

The error happens around 9:30PM, just when the backup has finished or is finishing I guess... Publish Related resources atapi error event id 11 solution Error: Source "calnts" event ID 4 and 11 Forum NTDS event id: 1168 error 1(1) Forum Event ID 51, 9, and 11 But I don't think ignoring these errors is a good strategy.After reading some MS forum I tried this: Set service "Windows Driver Foundation User mode Driver Framework" to automatic (wudfsvc). But this is just an assumption.

Thought it would be one last spot in the equation. Got the error yesterday twice with the service stopped. Just changed that one as well. grumble 0 Message Author Comment by:Jsmply2010-07-02 Just to note, that process ID 4 message that showed up you and Noxcho are talking about, that only happended ONCE in two weeks

Run manufacturer hard disk diagnostics. If a hardware issue is suspected, these articles may be useful in determining exactly what hardware is at fault: How to Troubleshoot Error Messages about Event ID 9 and Event ID x 275 Corey Monteiro Boot-up was also very slow when these errors began to occur. Event ID: 11 Source: Disk Source: Disk Type: Error Description:The driver detected a controller error on \Device\Harddisk0\DR0 English: This information is only available to subscribers.

If you have only one drive, ensure you do not have it configured to cable select and update to the latest IDE drivers from your motherboard manufacturer". Perhaps it is VSS, perhaps VSS runs low priority in the backgroud (as you might expect) and Win7 considers it "safe" to remove regardless of whether it is finished or caught The hardware seems to check out fine by all diagnostics. 0 Message Author Comment by:Jsmply2010-07-01 Windows 7 has an advanced power save feature for "USB selective suspend setting" which is x 259 Anonymous In my case, after I disabled S.M.A.R.T.

They seem to think it's either related to the Seagate drive sleep setting, or just the way the bridge card on the drives work. that should help. Expand storage on the left and select disk management. Think of it this way though, it happens when you ask to safely remove, so what if, to fulfill that request it's trying to flush out writes, gets a bit of

I thought this was due to one of the HD controllers playing up. Good news and this question is really worth of being added to EE knowledge base. Anyone have any input on how to fairly divide the points? Thinking about it I would not expect indexing to run inside the kernel, although virtual memory management certainly would.

WIll post back shortly. 0 Message Author Comment by:Jsmply2010-07-01 Okay, took a look. Join our community for more solutions or to ask questions. After a while the D: drive failed. After lots of drive and cable swapping I have discovered it happens because I have the drive caddy plugged into a Noontec USB3 hub.

Vincent und die Grenadinen Südafrika Surinam Swasiland Tadschikistan Taiwan Tansania Thailand Togo Trinidad und Tobago Tschad Tschechien Tunesien Türkei Turkmenistan Turks- und Caicosinseln Uganda Ukraine Ungarn Uruguay USA Usbekistan Vanuatu Venezuela At first, I thought it was just a hardware problem with the system I got, but it's replacement suffered from the same thing. If you had an identical machine heck you could swap drives and cards yourself. It seems to only occur when the drive is actually physically swapped in the AM (and then occasionally random times after that). 0 LVL 46 Overall: Level 46 Storage Hardware

x 136 EventID.Net As per Microsoft: "ATA66 DMA transfer mode is not supported for the onboard IDE controller." See the link below. I run ms cluster on two pc. more hot questions question feed about us tour help blog chat data legal privacy policy work here advertising info mobile contact us feedback Technology Life / Arts Culture / Recreation Science Recommend Us Quick Tip Connect to EventID.Net directly from the Microsoft Event Viewer!Instructions Customer services Contact usSupportTerms of Use Help & FAQ Sales FAQEventID.Net FAQ Advertise with us Articles Managing logsRecommended

These drives are used regularly. The "Harddisk5" should refer to "Disk 5" in Disk Management however. Deutschland Länderauswahl Afghanistan Ägypten Albanien Algerien Amerikanische Jungferninseln Angola Anguilla Antigua und Barbuda Äquatorialguinea Argentinien Armenien Aruba Aserbaidschan Asien/Pazifik Äthiopien Australien Bahamas Bahrain Bangladesch Barbados Belgien Belize Benin Bermuda Bhutan Bolivien