Make sure the wires are still connected, but pulled back just enough so that you can get the meter leads on the terminals as well. My Kenmore water heater is controlled by the Honeywell Gas Valve (part # 9007884), which contains the WV8840 Communication Port. that's a lot of money to have spent for trial and error diagnostics and parts that didn't resolve the issue. Submitted: 2 years ago.

Air conditioner Refrigeration Heat Pump Boiler Troubleshoot the boiler > Boiler burner won't stay lit Hot water boiler design Ductwork design and troubleshoot How ductwork is designed Thermostats Diagnostic problems Tools So, I decided to let it sit overnight and that did the trick for me. I reconnected it, and the furnace worked through an entire cycle with no problems. Nobody likes frigid mornings... · actions · 2010-Jan-7 10:31 pm · mabatchejoin:2000-10-10Lake Zurich, IL

mabatche to quitecoolatm Member 2010-Jan-8 10:05 am to quitecoolatmIronically, just last week I had a very similar

I'm getting a six red flashes as a code. ( Gas valve communication error )I have tried putting a new gas valve on but still have same error.Furnace runs on all The gas valve had five wire connected to it. Wird verarbeitet... Don't do it Waterheatertimer.org is a self-help site Replace water heater element Figure Volts Amps Watts for water heater 9 ways to save with water heater How to install point of

I then sucked on the tube slightly so the pressure switch diaphram would cause the switch to click. All flash code sequences are broken by a 2 second"off" period.SLOW GREEN FLASH: Normal operation.SLOW AMBER FLASH: Normal operation with call for heat.RAPID RED FLASH: Twinning error, incorrect 24V phasing. Have the model and serial #'s ready.1-800-536-6112 is Johnson Controls phone number. And two finger-pressable connectors at the top.

The furnace will lock out for one hour and then restart.8 RED FLASHES: This fault is indicated if the flame is lost 5 times (4recycles) during the heating cycle. Lastly, it might be the control board, since once in a while the LED would stay red.Any thoughts?Edit: sorry for the double post, can a mod close the other thread? · I agree with Michael, look at replacing it. Either the gas valve opens up and the furnace completes it's normal cycle, or the gas valve doesn't open up and it seems to cycle the glow plug off and on

Bitte versuche es später erneut. if the gas valve was faulty, I'd expect the valve to maybe close sometimes when the furnace is running, and I haven't seen that- I don't think it's an obstruction in The furnace will lock out for one hour and then restart. 9 RED FLASHES: Indicates reversed line voltage polarity or grounding problem. Lockout may be manually reset by removing power from the control for more than 1 second or removing the thermostat call for heat for more than 1 and less than 20

They own Coleman, York, Carrier, Unitary ect.. Be sure to reset the switch after correcting the failure condition. 6 RED FLASHES: This indicates that after the unit was operating, the pressure switch opened 4 times during the call It's not very complicated, really. You may have a gas leak at the valve.2 red colored flashes means that the switch that controls pressure is possibly stuck.

Wiedergabeliste Warteschlange __count__/__total__ 7 Tips and Tricks to repair your Furnace DIY JRESHOW AbonnierenAbonniertAbo beenden19.74819 Tsd. Sprache: Deutsch Herkunft der Inhalte: Deutschland Eingeschränkter Modus: Aus Verlauf Hilfe Wird geladen... This could be from a gas valve closing slowly or a burner flame lingering.7 Read seven LED flashes as a warning of a low flame sense microamp signal. This will give you an idea if its an issue with intake air or not.

After it stops I lower the thermostat wait 5 minutes , crank it up , the furnace will start again. Melde dich an, um dieses Video zur Playlist "Später ansehen" hinzuzufügen. Mounting Pictures on Wall - Child Safe [HomeImprovement] by nightdesigns254. Check and clean flame sensor.

We are 6 months out of the labor warranty but within the parts warranty. If you have any problems with the registration process or your account login, please contact support. our first step is to see where it is breaking circuit.Put one lead on TR at thermostat and the other at C (Common) leaving the board and tell me if you Here are error codes found on many York, Trane, Luxaire, Lennox, Carrier, Coleman and Rheem furnaces These codes are not listed with applicable model #s.

So if the pressure switches were just being finicky, I would expect the furnace to cut out by itself mid-cycle once in a while. · actions · 2010-Jan-6 10:47 pm · We replace the gas valve, but the same problem remain. Wird verarbeitet... When all else fails, you have to call an expert, but first try the steps in this video.Here is a list of codes that was posted to www.doityourself.com by Huston204Flash sequence

The one thing we didnt' do was swap out the gas valves from the working furnace to the non-working furnace. We replaced the controller board, the same problem was still there. The Flame LED shall flash rapidly when lockout is due to undesired flame.Soft Lockout - The control shall not initiate a call for heat or call for continuous fan while in Wird geladen...

I believe that furnace fires at 70% of full rate for 30-45 seconds, then drops to the minimum 35% firing rate. For example, six “on” flashes equals a number 6 fault code. The past 5 error codes are 5 Amber - 6 Red - 5 Amber - 6 Red - 5 Amber 5 Amber says "Heating capacity is reduced due to restriction in Just make sure you label (or cell phone picture) where the wires go, to be able to return them, and then disconnect all the wires.

Anmelden 3.057 228 Dieses Video gefällt dir nicht? Check for proper gas flow. 1 RED FLASH: This indicates that flame was sensed when there was not a call for heat. Checkpolarity at furnace and branch. Rheem failure codes FLAME LEDThe FLAME LED is an indication of thepresence of flame.OFF – No flame is detected.Rapid Blink – Unexpected FlameSlow Blink – Marginal Flame SenseSteady ON – Normal

Both furnaces displayed Error code 35 (gas valve communication error) and the tech from Air-Tech (authorized Bryant repair) replaced both the circuit board and gas valve to be save. Check and clean filters, tighten wiring and check the flue for blockages.6. SLOW AMBER FLASH: Normal operation with call for heat. Schließen Ja, ich möchte sie behalten Rückgängig machen Schließen Dieses Video ist nicht verfügbar.

what are you touching the other lead to? Our company we just relocate the intake and call it a day, no call backs so far. Ok, that's done. You may freely link to this site, and use it for non-commercial use subject to our terms of use.

With this fault code the control will operate the supply air blower and inducer. Contest! ! ! ! ! The time now is 09:59 PM.