flexlm error 15 Outlook Washington

Address Selah, WA 98942
Phone (509) 698-3546
Website Link
Hours

flexlm error 15 Outlook, Washington

Provider of BBx® Generations. All rights reserved. Cause Not specifying the default lmgrd port number of 27000 may result in the failure of the client to connect to license server, even if the client machine is not behind All rights reserved.

In order for the license manager to work with network security software and firewalls, you must specify an open port on your system for MLM. An Error Occurred Unable to complete the action because of changes made to the page. System Error Explanation (optional)--a short sentence (< 80 characters) explaining the system error. On Solaris or Linux, the equivalent system error message is "Connection refused".

Check the license manager debug log file that was specified when configuring the license manager. Either the hardware dongle is unattached, or the necessary software driver for this dongle type is not installed. -112 Missing dongle driver. Use the License Key Administrator to configure the License Usage Mapper (Settings > License Usage Mapper) to configure the ClearCase LT Server to use a Rational Suite license. more » NEW ENVI Pocket Guide Vol. 1 | Basics An ENVI quick reference booklet that provides users succinct steps on how to accomplish common tasks in ENVI.

To work around this, you must first define the ports to be used by both the lmgrd and armlmd license server daemons, and then reconfigure your firewall to allow accesses to Yes No We're glad to know this article was helpful. You may need administrator privileges to edit these files. 3. Discover...

Related Content Join the 15-year community celebration. Document information More support for: Rational ClearCase Rational Common Licensing Software version: 7.0 Operating system(s): Windows Reference #: 1129413 Modified date: 2007-02-14 Site availability Site assistance Contact and feedback Need support? Submit Rating and Feedback Link to this article Copyright © 2011 ARM Limited. You may also need to define and open the port used by the vendor daemon, which is dynamically assigned when the license manager starts by default.

Learn more MATLAB and Simulink resources for Arduino, LEGO, and Raspberry Pi Learn more Discover what MATLAB® can do for your career. Products MATLAB Related Content 1 Answer MathWorks Support Team (view profile) 13,637 questions 13,637 answers 13,636 accepted answers Reputation: 2,607 Vote0 Link Direct link to this answer: https://www.mathworks.com/matlabcentral/answers/91576#answer_100927 Answer by MathWorks Join the conversation Join Sign in Search Search Options Search Everything Search Licensing Micro Focus Home Micro Focus Borland More ... Check the Configuration using Services radio button.Select the Start/Stop/Reread tab.

The license server name is too long There is a character limit on host names imposed by the FLEXlm licensing software.If the license server's hostname is longer than the limit, you Opportunities for recent engineering grads. Close × Select Your Country Choose your country to get translated content where available and see local events and offers. SOLUTION: Make sure that port 1700 is opened for TCP communication through any firewall that is enabled on the server or client machines.

For example, if your IDL 6.4 installation is located at C:\Program Files\ITT\ IDL64 and license manager was started using a license file with the following SERVER line: SERVER myserver 00b012345678 1700 It is recommended that both the server and workstation IP address be included in both hosts files. Sample hosts file entries: 192.134.1.123 server_name 192.134.1.124 workstation_name If you are using DNS, verify that your BASIS License System Error: 10061 "Winsock: Specified socket is invalid"There is a port number conflict.The license manager operates using two TCP ports.In order to use a firewall with FLEXnet, you will need to System Error: 10038 "Winsock: Specified socket is invalid"A variation on this error is: ERROR: License Manager Error -15 Cannot connect to license server The server (lmgrd) has not been started yet,

The vendor daemon can't handle any more users. Add an entry of the form: 123.456.789.012 myserver.mycompany.com On Solaris or Linux, the hosts file is/etc/hosts. The firewall can block requests from the client despite the server being operational. United States Patents Trademarks Privacy Policy Preventing Piracy Terms of Use © 1994-2016 The MathWorks, Inc.

For more information, please refer to the FLEXlm End User Guide, version 9, section B.1.3 (the document, enduser.pdf, can be found in the Utilities/FLEXlm directory of your ARM RealView tools CD-ROM). Symptom After a Rational product is installed, attempting to connect to license server using the License Key Administrator results in the FLEXlm -15 error. The license key/signature and data for the feature do not match. Obsolete with v8.0+ vendor daemon. -38 User/host on EXCLUDE list for feature. -39 User/host not on INCLUDE list for feature. -40 Cannot locate dynamic memory. -41 Feature was never checked out.

This is probably because the license is older than the application. change the line to read: SERVER 127.0.0.1 0000123abcd 1700 NOTE: If network configuration problems are suspected in causing the licensing problem, please contact your system administrator for assistance. 7.) PROBLEM: There See the system administrator about starting the server, or make sure that you're referring to the right host (see LM_LICENSE_FILE environment variable). -97 The desired vendor daemon is down. 1) Check To define this port, please see Tech Tip 1210Solution: [Edit this field in the IDL-based Tech Tip Editor, v80] Rate this article: 4.3 Related Topics: Help Articles, Licensing Tags: Number of

Search FEATURED HELP ARTICLE Exelis VIS Technical Support Policy Updates 9/25/2014 Maintenance Program Changes and Reminders: All customers must be current on maintenance to receive ... How can we improve? These numbers are unique error identifiers and are used by FLEXlm vendors for more advanced support assistance. Apply Today MATLAB Academy New to MATLAB?

SOLUTION: Verify that the application is using the proper license file. System Error: 61 "Connection refused" E.2 Error Code Descriptions The following table lists the most common errors produced by FLEXlm-licensed products. This explains how to set the vendor daemon port number. For ARM tools using FLEXlm versions 8.1b and older(for instance, RVCT 2.0 and ADS 1.2.x), the limit is 32 characters.

FLEXlm error -15,10 "Cannot connect to license server" or "WinSock: Connection refused" Saturday, September 15, 2001 Topic: For floating license trouble shooting: Symptom: When starting a Windows IDL or other RSI This is a warning condition. This port is used for the initial connection to the license server. In order to read the dongle hostid, the correct driver must be installed.

These error messages may occur in two formats available with FLEXlm or may appear in a format customized by the application. System Error: 10061 "WinSock: Connection refused" Discussion: This error indicates that the FLEXlm routines in the application are unable to make a TCP connection to the server and port specified in Home » Micro Focus » Licensing Micro Focus » Licensing Micro Focus Knowledge Base » FLEXlm error : Can?t connect to license server (-15,12) Connection refused FLEXlm error : Can?t connect Based on your location, we recommend that you select: .

Learn MATLAB today! Other supporting information (optional) Error messages were improved in v6. There are a number of different causes for this error message. 1. antivirus)- Uninstall wireless networking software- Uninstall software/drivers for on-board infrared devices- Reinstall the TCP/IP network stack- If the license manager is on Windows Vista, move the license manager files from the

Skip to main content Home Site map Contact us Partner login Home Site map Contact us Partner login Main menu ShowcaseShowcase OverviewBusinesses Running on BASISSuccess StoriesBBx Web Showcase LiteratureTech Move your mouse over the bar and click Did you find this article helpful? If a node lock license is used, a FLEXlm error -15 will result, as the license program is looking for a floating license. If you do not have a port number on the end of this line, you will need to specify a port.

See the debug log for further information. -110 Dongle not attached, or can't read dongle. For example, if the SERVER line in the license data file reads: SERVER servername 0000123abcd 1700 ... If both of these processes are not there, then stop and restart the license manager program. Windows: Check Task Manager/ Processes for basis.exe and basis_lmgrd.exe processes. Use a Rational Suite product node lock license (if available) Install the Rational Suite product on the ClearCase LT Server Import the node lock Rational Suite product license onto the ClearCase