failed to initialise session opl library error Goodview Virginia

Address 4707 Valley View Blvd NW, Roanoke, VA 24012
Phone (540) 362-4080
Website Link http://www.geeksquad.com
Hours

failed to initialise session opl library error Goodview, Virginia

in the rules file you have to define the table with the statement: table xxxx = “xxxx/xxxx.lookup" default = {"xxxx","yyyy","zzzzz"} You mixed both solutions. SystemAdmin 110000D4XK 1283 Posts Re: Including lookup table ‏2007-11-07T10:15:50Z This is the accepted answer. Mojica Roa To: users at netcoolusers.org Sent: Wednesday, July 31, 2013 1:43 PM Subject: Re: [INUG-Users] nco_pa_status, stop and start not working Hi Mario, You can start the Check that you have included the file at the correct position within the switch($enterprise) statement - that'll lead you to the error, I suppose.

SystemAdmin 110000D4XK ‏2007-11-07T09:38:52Z First, thanks for helping me. However, the probe is reading the rules from the wrong directory - 05/20/09 13:35:45: Information: Connecting ... 05/20/09 13:35:45: Debug: Reading /opt/netcool/omnibus/probes/linux2x86/syslog.rules 05/20/09 13:35:45: Error: Failed to open Rules file: /opt/netcool/omnibus/probes/linux2x86/syslog.rules include.snmptrap.rules 2014-02-12T15:31:27: Debug: D-UNK-000-000: Including /opt/ibm/tivoli/netcool/rules/include-snmptrap/AssignCorrectAdvValue. Attachments attachment_14010955_working.zip 2 KB Log in to reply.

This is the accepted answer. and at the beginning of the file. Can you check permissions on the radview.lookup file ? SystemAdmin 110000D4XK ‏2007-11-07T09:05:19Z Im including the table file in mttrapd.rules (the general default file) table radview = "/opt/netcool/ominbus/probes/solaris2/radview.lookup" and it is the very fist line after all the comments.

Message was edited by: Shahar_Karny,RAD More... Then I tried the nco_pa_status using the root user and the netcool user....you can > see below that with the root user the nco_pa_status works.....with the > netcool it doesn´t: > Error: 11/07/07 11:25:43: Information: Connecting ... 11/07/07 11:25:43: Debug: Reading /opt/netcool//omnibus/probes/solaris2/mttrapd.rules 11/07/07 11:25:43: Debug: Plain text rules file detected. 11/07/07 11:25:43: Error: Rules file '/opt/netcool//omnibus/probes/solaris2/mttrapd.rules' line 74: Failed to read lookup Log in to reply.

Shahar Karny RAD Log in to reply. YOU ARE SO RIGHT. (it works now) If you had any idea how much time I burned b4 coming to the forum. This is the accepted answer. I tried with a TAB for separation it doensn't work.

More... Also pasted your lines, and Im still with these errors... This is the accepted answer. First, thanks for helping me.

If you have received this message in error, >> please notify the sender immediately and promptly destroy any >> record of this email. >> _______________________________________________ >> Sent by the netcoolusers.org "users" This time a question for 200$... Everything is working...TIP is showing >>> everything....BUT....the only way I can start the Object Server is using >>> the "nco_pad -name" command....the ObjServer starts, but no nco_pa >>> command works....I cannot it gives you debug messages by default.

SystemAdmin 110000D4XK 1283 Posts Re: Including lookup table ‏2007-11-07T09:04:13Z This is the accepted answer. I tried the table I pasted in my rules file it works ... (quotes and comma) (it didn't work without quotes...) Did you make sure your table definition is before any Group is already assigned to a user >>> or role on line 1 of statement 'alter group 'Netcool_OMNIbus_User' >>> assign members 'ncoadmin';' >>> 2013-07-22T19:25:11: Error: >>> E-OBX-102-019: Failed to execute parsed or its affiliates >> via email, or email attachment.

The problem you are facing with the Process Agent i think is with the authentication. Second, i understand that you are talking to the point, but it just wont pass: lookup table - so simple : .1.3.6.1.4.1.164 RAD_Data_Communications the new mttrapd.rules file: table radview = "/opt/netcool/ominbus/probes/solaris2/radview.lookup" Barry >> Gulf Breeze Software Partners >> lonny.barry at gulfsoft.com >> (979) 476-9779 >> >> "We are what we repeatedly do. Second, i understand that you are talking to the point, but it just wont pass: lookup table - so simple : .1.3.6.1.4.1.164 RAD_Data_Communications (TAB included) the new mttrapd.rules file: table radview

Cheers, Michael Troitzsch Solution Architect DICOS GmbH Kommunikationssysteme Alsfelder Straße 11 D-64289 Darmstadt Tel: +49 6151 82787 31 Mobil: +49 1761 82787 31 Fax: +49 6151 82787 59 I have made all > the > > changes according to the doc provided from Muse > with > > the download. does >> not guarantee the accuracy of any email or email attachment, that >> an email will be received by Citizens Financial Group, Inc. Updated on 2007-11-07T09:07:36Z at 2007-11-07T09:07:36Z by SystemAdmin SystemAdmin 110000D4XK 1283 Posts Re: Including lookup table ‏2007-11-07T09:18:49Z This is the accepted answer.

The server002 on the log below is the >>> OMNIbus Serevr, the server003 is a TIP Server on a separated machine: >>> >>> 2013-07-22T19:17:41: >>> Error: E-OBX-102-019: Failed to execute parsed Also pasted your lines, and Im still with these errors... Error: 11/07/07 11:17:43: Information: Connecting ... 11/07/07 11:17:43: Debug: Reading /opt/netcool//omnibus/probes/solaris2/mttrapd.rules 11/07/07 11:17:43: Debug: Plain text rules file detected. 11/07/07 11:17:43: Error: Rules file '/opt/netcool//omnibus/probes/solaris2/mttrapd.rules' line 74: Failed to read lookup More...

I seems ok no? Ensure the Name property is set first in the property file. In no event shall Citizens Financial Group, Inc. I am trying to fix this so I can start event receiving tests. > > Please advise. > Mario > > > > ________________________________ > From: Mario Behring