facility_itf error codes Ft Myer Virginia

Address 4502 Jones Bridge Rd, Bethesda, MD 20814
Phone (301) 718-0822
Website Link
Hours

facility_itf error codes Ft Myer, Virginia

In it, you'll get: The week's top questions and answers Important community announcements Questions that need answers see an example newsletter By subscribing, you agree to the privacy policy and terms For example, the status code STG_E_FILENOTFOUND indicates a storage-related error has occurred; specifically, a requested file does not exist. Microsoft recommends that when using FACILITY_ITF you use errors in the range of 0x0200 to 0xffff. All COM+ and Windows errors as well as the aforementioned macros are defined in the winerror.h system include file.

Only the highest-order bit designated the severity. share|improve this answer answered Mar 17 '12 at 0:51 Ian Boyd 85.4k150529858 I read that more as a realization than an endorsement. As a result, the 32-bit HRESULT is structured such that Microsoft can define several universal error codes, while allowing other programmers to define new error codes without fear of conflict. This means that the same 32-bit value in FACILITY_ITF returned from two different interface methods might have different meanings.

Once you have a resolution, please remember to post it.Cheers,AndrewLike • Show 0 Likes0 Actions agreiner Mar 4, 2011 10:57 AMI am having a similar issue. Also, what if the method call on AInterface internally called the method on BInterface? The R, C, N, and r bits are reserved in both. FACILITY_STORAGE For status codes returned from IStorage or IStream method calls relating to structured storage.

FACILITY_DISPATCH For late-binding IDispatch interface errors. The associated error in the ArcGIS Server log is:"Method failed.HRESULT = 0x8004020c : This is a FACILITY_ITF error that is specific to the interface that returned this error. A facility helps identify from where the error came. Tech support is supposed to be getting back to me on this error soon I think.

The bit is set for customer-defined values and clear for Microsoft-defined values. <1> <1> Section 2.1: All HRESULT values used by Microsoft have the C bit clear. You signed in with another tab or window. Hot Network Questions Exploded Suffixes With the passing of Thai King Bhumibol, are there any customs/etiquette as a traveler I should be aware of? To avoid conflicting error codes, whoever defines the interface is responsible for coordinating and publishing the FACILITY_ITF status codes associated with that interface.

If you put MESSAGETABLE resource into your binary, FormatMessage API could resolve HRESULTs and extract description text for individual codes, just like it happens with regular Windows error codes (the app Reload to refresh your session. See also: Creating your own HRESULT? See the documentation of the interface that returned this error for information about this HRESULT. "I can't find much relevant on either of these errors and the errors themselves don't tell

Why does argv include the program name? I just tried creating the local copy for editing in ArcMap while using ArcMap as the ArcGISSOC user too. Figure 6-1. That is, two SCODEs or HRESULTs with exactly the same 32-bit value returned from two different interfaces might have different meanings.

As are E_NOTIMPL, E_POINTER and E_FAIL. Not the answer you're looking for? But what happens when I use both components and need to differentiate the source of the error? Appease Your Google Overlords: Draw the "G" Logo House of Santa Claus Can Communism become a stable economic strategy?

In addition, you can define new status codes using only the FACILITY_ITF facility code, and then only in the range 0x0200 through 0xFFFF to avoid conflicting with Microsoft-defined status codes in i might have an HttpGet() function that returns ERROR_ACCESS_DENIED if the server returns a 401. IErrorInfo is also (arguably) unacceptable overhead if you're not catering for a client that needs to display the error values to the user. If set to zero, SEVERITY_SUCCESS, the value indicates success.

Edit: Thanks to bgrainger for pointing out the correct recommended range.

Back totop Search this blog Search all blogs Share This PostShareShareShareShareShare Recent Posts Changes to Visual Studio "15" Setup September Browse other questions tagged winapi or ask your own question. The top bit (31) defines the severity code of the HRESULT value. If you're using Operating System Authentication with SDE, consider testing the ArcGISSOC permissions by running ArcMap as the ArcGISSOC user.

For example, the code for MK_E_MUSTBOTHERUSER is a combination of the moniker facility (MK), an error severity (E), and a status code indicating that user input is required for the operation But the same spirit starts to apply to COM error codes: E_NOTIMPL: 0x80004001 Not implemented E_INVALIDARG: 0x80070057 One or more arguments are invalid E_FAIL: 0x80004005 Unspecified error (The dreaded 80004005 unspecified In the days of 16-bit computing, an HRESULT was only a 16-bit signed integer while an SCODE was a 32-bit signed integer. We've set this up and got it working on another instance of ArcGIS Server 10, so I know it can work.

This facility has a value of 3. Codes in FACILITY_ITF HRESULTs with facilities such as FACILITY_NULL and FACILITY_RPC have universal meaning because they are defined at a single source: Microsoft. This is a new install of ArcGIS Server Advanced Enterprise using a Map service with feature access enabled that consumes an ArcSDE geodatabase based in SQL 2005. If you're using Database Authentication, make sure the Check Box for save username and password is checked.3.

Error codes are defined within the context of an interface implementation. By convention, HRESULTs generally have names in the following form: __ where is either the facility name or some other distinguishing identifier, is a single letter, S or E, We have a financial system that requires a 2nd user to approve a transaction; this means that the entered credentials must be a different user than the first person: MK_E_MUSTBOTHERUSER: "User The companion CD contains a simple utility named Error that interactively decodes HRESULT values.

I think that we might as well follow the advice. Make sure to use an Internet Connection to the GIS Server for this. Is it appropriate to tell my coworker my mom passed away? It was user error in my case as I did not have an output directory set, so if you're having this issue have a look at the output directory under parameters

S_FALSE is not treated as an error because the severity bits are 0. HCM_DATAMONITOR_SEND_DATA 0x00000001 HCM_DATAMONITOR_SEND_ALLDATA 0x00000002 HCM_DATAMONITOR_RECV_DATA 0x00000004 HCM_DATAMONITOR_RECV_ALLDATA 0x00000008 Bit Flags for Encryption Strength (where available) HCM_ENCRYPT_STRONG 0x00000001 HCM_ENCRYPT_EXPORTABLE 0x00000002 Pre-Defined Session States The code that displays when the session has been Yes the codes would overlap between applications, but you can also provide additional descriptive message through SetErrorInfo API and indicating support by implementing ISupportErrorInfo if you are implementing COM object/interface. Fiddler does not show any errors as I run the process.

FACILITY_RPC For status codes returned from remote procedure calls. Facility Value Meaning FACILITY_NULL 0 Used for general error codes such as S_OK FACILITY_RPC 1 Errors from Remote Procedure Calls (RPCs) FACILITY_DISPATCH 2 Errors from the IDispatch interface FACILITY_STORAGE 3 Errors Please turn JavaScript back on and reload this page.All Places > GIS > Enterprise GIS > ArcGIS Server (10.0 and prior) > DiscussionsLog in to create and rate content, and to Hugh Askari Risk Management Solutions 23 Watts Street 4th Floor New York, NY 10013 Ph: 212 219-0730 x30 Fx: 212 219-2247 http://www.askari.com http://www.interlog.com/~hubrown -----Original Message----- From: Distributed COM-Based Code [mailto:[email protected]]On Behalf

Why would a password requirement prohibit a number in the last character? FACILITY_WIN32 Used to provide a means of handling error codes from functions in the Win32 API as an HRESULT. This would ensure the account can edit the data.2. The system returned: (22) Invalid argument The remote host or network may be down.

NET> Date: 1999-03-02 16:28:29 [Download message RAW] I am tagging onto this thread with (hopefully) a relevant question: If I design 2 COM components (A and B), each with 1 interface We recommend upgrading to the latest Safari, Google Chrome, or Firefox. I really enjoyed the fact that the explanation was paired up with the layout of the bits. This guarentees // they won't conflict with Windows HRESULTS for other facilities, or with COM HRESULTS. // // // General error codes specific to the DMap support code. // // //