It is more usual, however, to quote a sensor as having a flat response between specified limits of frequency. If you have 2°error for a 50° span, I would say that you do indeed have a 4% error, 2/50.If your comparison is to a traceable standard, I'd say something is So, with the meter reading 1 volt, the actual input could be anything between zero and two volts, and with the meter reading 100 volts the actual input could be anywhere Zero Adjustments: Used when "setting up" a transducer to adjust the output signal to zero when zero load/pressure is applied.

Hope this clears things up. All rights reserved.Unauthorized reproduction or linking forbidden without expressed written permission. PSIA: Pounds per square inch absolute. The table below shows the uncertainties in the measurement of force, first given as 1 % of reading and second expressed as 1 % of full-scale reading to illustrate the difference; in the

For example: “AL111” will yield the most results. “AL111BN,1A,2U” will start to narrow the search Use the * symbol at the end of a word, part number, partial part number or At 100 VDC, the tolerance would then be 98 to 102 VDC, at 50 VDC the tolerance would be 98.5 to 101.5 VDC, and so on. The deviation is expressed as a percent of full scale. Registration on or use of this site constitutes acceptance of our Privacy Policy.

Zero When making a measurement it is necessary to start at a known datum, and it is often convenient to adjust the output of the instrument to zero at the datum. The process engineers I've worked with wouldn't worry about that loop yet, if your measurement is correct. Can a GM prohibit a player from referencing spells in the handbook during combat? In the United States is racial, ethnic, or national preference an acceptable hiring practice for departments or companies in some situations?

Already a member? The industrial measure is often made under reverse conditions. shard923 View Public Profile Find all posts by shard923 Post Number #5 2nd August 2004, 04:34 PM Tim Folkerts Total Posts: 972 I've seen uncertainties on instruments Output: The electrical signal measured at the output terminals that is produced by an applied input to a transducer.

It represents the highest possible input value which can be applied to the sensor without causing unacceptably large inaccuracy (shown in Figure 3). Tim F Tim Folkerts View Public Profile Find all posts by Tim Folkerts Lower Navigation Bar The Elsmar Cove Business Systems and Standards Discussion Forums > Common Quality Assurance Processes This process is known as calibration, and the devices that produce the input are described as calibration standards. Different meanings of '1 % uncertainty' Percent of reading Percent of full-scale reading Instrument reading (newton) Uncertainty in(newton) Equivalent ‘percentage of full-scale reading’ Uncertainty(newton) Equivalent ‘percentage of reading’ 1000 10 1% 10

Hot Network Questions IQ Puzzle with no pattern Conference presenting: stick to paper material? Click Here to join Eng-Tips and talk with other members! Along with hysteresis and zero balance. B.2 Equipments with % Reading Generally, when manufacturer advertise % reading, their useful range will be given from minimum to full scale i.e.

The points are taken on the same continuous cycle. Deflection Drawing Diaphragm: The sensing membrane that is deformed when pressure is applied. Transmitter: A transducer that has a 4-20 mA two-wire output. Output Impedance: The resistance as measured on the output terminals of a transducer at standard temperature, with no measured applied and with the excitation terminals open-circuited.

If the transmitter has not drifted, any reading between 54 deg. Sensitivity Sensitivity of a sensor is defined as the change in output of the sensor per unit change in the parameter being measured. Join Us! *Eng-Tips's functionality depends on members receiving e-mail. Yours may worry about it so ask them.Contrast that spec with 1% of reading, which is more accurate.

Specifications: The group of error limits within which each device will operate. Shunt CAL (R-CAL): The change in electrical output caused by placing a fixed resistor between the appropriate transducer terminals. So if the measurement is at mid-scale (12mA) then that error could be +/-2% of reading. Reasons such as off-topic, duplicates, flames, illegal, vulgar, or students posting their homework.

Cancel Red Flag SubmittedThank you for helping keep Eng-Tips Forums free from inappropriate posts.The Eng-Tips staff will check this out and take appropriate action. Bridge Drawing Bridge Resistance: The nominal value of the individual legs that make up a complete Wheatstone bridge. When, where, and how, was it done, relative to the other measurement that you are questioning? You would apply that same calculated tolerance anywhere in that range.

Why would a password requirement prohibit a number in the last character? This will prevent the user, from having to calculate what the real error or uncertainty is at any given range. Community Links Social Groups Pictures & Albums Registered Visitors Search the Cove Forum Discussion Threads Show Threads Show Posts Tag Search Advanced Forum Search Search Elsmar Unanswered Threads Find All Transducer: A device (or medium) that converts energy from one form to another.

Temperature changes to scale and zero, and aging often must be added on top of that. In the case of thermocouple instruments, the cold-junction compensation is added on top (and may be specified as a ratio such as 20:1, meaning a 20°C change in ambient temperature could Here is something to think about that we just had to deal with at my cal shop. F.

Join UsClose A Uncertainity of the equipment: There are two ways of stating measurement error and uncertainity for the entire range of measuring instrument. for example ± 0.5% reading from 10Nm to 100 Nm (10% to 100%), this is because constant uncertainty or error cannot be achieved due to various reasons below 10% of full Full Scale Output: The algebraic difference between the minimum output (normally zero) and the rated capacity. Bridge: A Wheatstone bridge configuration using four active strain gauges.