Remove the four screws shown in the picture below and carefully lift the circuit board. FDS - Move Plastic Arm Next, push in the eject lever to raise the disk card holder while lifting the pressure arm out of the way. When I have something to compare with might make it easier to figure out the issue. You may be able to narrow down if the disk is damaged, or the drive needs to be calibrated...or if my theory that some programs are more sensitive is correct or

Changing the belt was the difficult part - recalibrating the drive was a cinch. Single-sided disks use $00 22 1 Disk number First disk is $00, second is $01, etc. 23 1 Disk type $00 = FMC ("normal card"), $01 = FSC ("card with shutter"). The read buffer is a part of the VRAM buffer at $300-$3xx, but the same location can't be used to transfer read and writes on the same frame (for example a Err. 05 = Disk card not authenticated (game name ID).

Be careful not to lose the circular plastic shims that are between the triangle and gears. If no matches are found after 20 bytes, or a -1 entry is encountered, [$09] is set to -1. I will add more information about some of the obscure codes when I see them happen again, as I will actually try to replicate them. RAM Adapter RAM Adapter The disk system attaches to the Famicom using a modified cartridge known as the RAM Adapter (HVC-023).

Note: Since the disk transfer routine also uses IRQs, it's very important to disable timer IRQs before doing any access to the disk. Err. 03 = Disk card is write protected. A call to WriteVRAMBuffer will execute faster than a call to VRAMStructWrite with $302 as an argument, but both will have the same effect. Reply With Quote 09-17-2006,06:57 PM #23 rbudrick View Profile View Forum Posts Private Message Ryu Hayabusa (Level 16) Join Date Sep 2002 Location Buying the rare ones, moments before you get

Forum » Home NintendoAge forum Users: 43 Logged-in / 27388 Total Category Topics Last Poster Welcome! ERROR 30 Disk card too full to save. Check out the Belt Replacement and Adjustment Tutorial if you need to replace the belt in your disk system. Its most lasting contribution to the NES scene was its disk image file format, an image of the Quick Disk media.

Test after each adjustment. Hacker reverse-engineered the disk format circa 1988, long before they started releasing Famicom cartridge games of their own. It will automatically send an error code if both CRCs doesn't match. Nintendo's disks, without a doubt were of the best quality, durability, and consistency.

is merely to document the meaning behind each error code. I also have the Disk System and my copy of Doki Doki Panic has the same problem (ERR. 27), except that mine won't work/load at all and never did. The disc drives only contains basic electronics, there is no "intelligence" in it; therefore, the serial interface almost directly represents what is stored on the disc. Since reading VRAM for nothing is not a harmful operation, the user can call ReadVRAMBuffer every frame even if nobody has to be read (no need for check flags) which is

Those are really your only options: rewrite the disk or send it out to get fixed. My original Xbox's DVD Drive's laser is dead and I don't have a replacement laser for it. Unfortunately, my only copy doesn't work.. Logged Xious Sharp C1 Posts: 1040 FDS Service Re: FDS Error Codes + Detailed Explanations of Each & Technical Info Quasi-F.A.Q. « Reply #2 on: January 08, 2012, 12:40:07 PM »

See the doc I translated here: http://simplynes.emucamp.com/copytool.html It tells you all you need to know about modding a FDS unit that needs modding for write ability. BIOS calls Disk access routines Routines takes one or two pointers as arguments. I would, but my drive is not a writeable one. Although, speaking of rewriting disks, in addition to the non-working DDP, I have a factory copy of Famicom Grand Prix: F1 Race that for some reason has the FGP II: 3D

If I see it anywhere else, don't be shocked if I come a-knocking. Once data from VRAM has been read, if it must be written back after a modification, the user need to copy it to the write buffer manually. It should be replaced if necessary. Maybe I should try that?

Posts 8,434 Last night I dumped some rare undumped FDS disks for Skrybe, and I realized something. This isn’t the usual fare from this blog, but this is good information that took me quite some time to find. Overview PRG ROM: 8 KB BIOS at $E000-$FFFF PRG RAM: 32 KB at $6000-$DFFF CHR capacity: 8 KB RAM Storage capacity: ~64 KB per disk side Nametable mirroring: Controlled by mapper Posts 8,434 ...tried posting that first link, but the board was erroring out for the last 20 min.

FDS Disk Side format Each disk side must be structured into block as follows: 1, 2, 3, 4, 3, 4, ...., 3, 4 The 3, 4 pattern should be repeated once Wiedergabeliste Warteschlange __count__/__total__ Famicom Sharp disk not loading, no error codes (help appreciated, read description) aunshi360 AbonnierenAbonniertAbo beenden88 Wird geladen... The actual buffer lies at $302-$3xx, and is of variable length. $300 is initialized to the value $7d, effectively making the buffer lie at $300-$37f. Data may be garbled, or out of sequence, etc..