Why does this execution plan have Compute Scalars? It's free, and you can customize the content you view, as well as being able to subscribe to threads and topics, getting new posts delivered to your email as they appear.UsernamePasswordRemember Is it plausible for my creature to have similar IQ as humans? Assume you have a 100 Nm torque tester (Maximum), and that the stated uncertainity as Case-1: At 100 Nm ± 0.5%FSD uncertainity is = 0.5 Nm for the entire range.

At 15 volts it would be: (15/50) x 2% or +/- 0.6%. Input Input Reading Enter the input value measured/recorded with a calibrator or other reference instrument that has a higher accuracy than the device under test. It is important that all input values For instance if an instrument is specified to have an uncertainty of ±0.3 % of full-scale output, and its maximum force capacity is 5 kN, then the user can reasonably hope that if You can only upload files of type PNG, JPG, or JPEG.

B Range of equipment: B.1 Equipments with %FSD Generally, when manufacturer advertise % FSD, their useful range will be from zero to full scale. You can only upload a photo or a video. This persisted even after new electronics were introduced (because no one asked the simple question "why?"). Add your answer Source Submit Cancel Report Abuse I think this question violates the Community Guidelines Chat or rant, adult content, spam, insulting other members,show more I think this question violates

Higher quality, higher price. Percentage error help? Therefore if a tester has 100Nm maximum range should not be used at less than 10Nm if the desired accuracy is needed. But for pressure sensors - FS %.Sergey Y.

government limits civilian GPS to accuracy only within 10 meters. It all depends upon how critical your measurements are and how accurate you want to be. Please upload a file larger than 100x100 pixels We are experiencing some problems, please try again. Charging of capacitor and op amp(integrator with dc and ac)?

Please try the request again. share|improve this answer answered Aug 2 '14 at 21:37 Andy aka 146k488223 add a comment| Your Answer draft saved draft discarded Sign up or log in Sign up using Google Highest Output Enter the highest possible output value that the device under test was designed to produce. It is important that all output values are entered in the same engineering units. The voltage measured by the meter is 15 and 42V.

So if the measurement is at mid-scale (12mA) then that error could be +/-2% of reading. The above explanation holds good for the error of the equipment expressed in % of reading and % FSD also. From the point of view of the user, it is advisable to state the accuracy or uncertainty in % of reading and the useful range corresponding to the accuracy or uncertainty. more stack exchange communities company blog Stack Exchange Inbox Reputation and Badges sign up log in tour help Tour Start here for a quick overview of the site Help Center Detailed

But if the force being measured is, say, 500 N the uncertainty, expressed as a percentage of the force, will be ten times higher, that is ±3 %. So the manufacturer continued to offer them as 1% meters.... Lowest Output Enter the lowest possible output value that the device under test was designed to produce. It is important that all output values are entered in the same engineering units. Case-2: At 100 Nm ± 0.5% of reading the uncertainity is = 0.5 Nm.

If Dumbledore is the most powerful wizard (allegedly), why would he work at a glorified boarding school? Using the 100 ln/min instrument again as the example, but this time with a stated accuracy of 1% RD, at 10 ln/min of flow the error is only +/- 1% of How to show hidden files in Nautilus 3.20.3 Ubuntu 16.10? The % RD accuracy value is dependent on the actual reading, so the error changes linearly with the reading.For example, if a pressure gauge has a % RD accuracy of 99%

Trending Now Lake Como Nick Jonas Jamie Dornan Prem Tinsulanonda 2017 Cars 2016 Crossovers Denver Broncos Annie Leibovitz Pittsburgh Steelers Skin Care Products Answers Best Answer: ±2% of full scale is Experienced consultants and project managers draw upon a unique combination of industry know-how and world-leading scientific discovery to deliver real-world business solutions and enable innovation and secure competitive advantage.Visit Commercial Services Temperature changes to scale and zero, and aging often must be added on top of that. means that if the scale is 4mA to 20mA, that error will not exceed +/-1.6uA (1% of the full scale deflection, which is 20mA-4mA = 16mA).

Lowest Input Enter the lowest possible input value that the unit under test was designed to measure. It is important that all input values are entered in the same engineering units. The system returned: (22) Invalid argument The remote host or network may be down. Is it slowing down or speeding up or the same since the big bang.? 8 answers Why can t most, or a lot, of calculators calculate -1^2 correctly? 14 answers Hi Yurish on 8 April, 2005 - 11:17 pmBut it is a tradition coming from the era of analog measuring instruments.Today it is dependent on a measurand and/or measuring instruments.

I would appreciate your help. One wonders if these design parameters have changed as they should to reflect modern electronics and microprocessors plus the ability to automate calibration means that intensive calibration routines are not the So the FS error is 100-99.5 = 0.5% FS, this means that the value of any reading can be off by (0.5/100)*(100-0) = +/- 0.5 kg.Percentage of reading accuracy is represented Please log in and try again.

Why was the identity of the Half-Blood Prince important to the story? Different meanings of '1 % uncertainty' Percent of reading Percent of full-scale reading Instrument reading (newton) Uncertainty in(newton) Equivalent ‘percentage of full-scale reading’ Uncertainty(newton) Equivalent ‘percentage of reading’ 1000 10 1% 10 Trending What speed is the universe expanding ? The following example will show the difference between the two.

An error specification of 1% F.S. Hence, care to be taken in selecting the right equipment used for calibration in the laboratory and also while issuing calibration report for the calibrated equipment. i.e. Why can't we use the toilet when the train isn't moving?

However, not all devices exhibit a linear behaviour and before there were such sophisticated electronics available the limitations of the electronics or the mechanical display devices imposed limits on accuracy claims.Devices To search the site, enter your search terms in the box labeled "search the site" and hit Enter.Some tips for better search results...Precede each search term with a "+", as follows:+Modbus In the case of thermocouple instruments, the cold-junction compensation is added on top (and may be specified as a ratio such as 20:1, meaning a 20°C change in ambient temperature could Take, for example, an instrument calibrated for a flow of 100 ln/min with stated accuracy 1.0% of FS.

This page served by Yesod4 in the beautiful Blackstone Valley of Massachusetts, the home of the American Industrial Revolution.Follow @c_com FortuneLife is wasted on the living. -- The Restaurant at the However, when a lower range is utilized this 0.5 Nm becomes more significant. show more The question is: A voltmeter who's accuracy is guaranteed to within 2% of its full-scale reading is used on its 0-50V scale. for example ± 0.5% reading from 10Nm to 100 Nm (10% to 100%), this is because constant uncertainty or error cannot be achieved due to various reasons below 10% of full

Expand» Details Details Existing questions More Tell us some more Upload in Progress Upload failed. What accuracy does the military have access to?Related QuestionsWhat is the difference between repeatability, accuracy and precision in robotics?What is the difference between full scale accuracy and span accuracy?What is the A simple conversion revealed a significant difference in performance.Then too, note that performance is often quoted as based at 20degC and lab conditions.For any meters it is important to understand what For others where a linear respoinse was not possible nor characterisation, a %fsd is more usual.Even with better electronics the next hurdle was the cost of a more intensive calibration needed

It is for above stated reason, that systems which have accuracy as related to indicated value (% of reading) should state the useful range to be 10% to 100% (or 20%