Measure voltage outputs across the vector drive terminals.Contact your local Haas Factory Outlet to verify your machine parameters are correct.If the parameters are correct, inspect the pins of the J3 connector This alarm can be caused by anything that...Page 4136 96-0284 rev G June 2009Alarms124 LOW BATTERY - Memory batteries need replacing within 30 days. Haas, Mazak, & Mori were the only machine tool companys. This year there were 38.....

haas mill lost manual axis moving new vf4 coolant flow question Powered by vBulletin Version 4.2.2 Copyright © 2016 vBulletin Solutions, Inc. The vector drive output is unbalanced.Corrective Action: Verify the parameters are correct. Should I do it? Check all of the motor leads and make sure they are properly connected.

Vector drive output The vector drive output is unbalanced. dk Reply With Quote 09-25-2005,05:50 PM #15 gar View Profile View Forum Posts Visit Homepage Stainless Join Date Feb 2005 Location Ann Arbor, Michigan USA Posts 1,336 Post Thanks / Like Home switch input changed state while machine was in use. G41 causing .005 X offset?

For example, the lift frame must be up while rotating, and down when a pallet change ...Page 44176 96-0284 rev G June 2009Alarms964 TOOL TURRET ROTATE FAULT - The turret did Reply With Quote 09-23-2005,11:37 PM #10 tnmgcarbide View Profile View Forum Posts Titanium Join Date Jul 2004 Location N. The circuit breakers will be labelled for coolant and main transformer and CB4 115v. I can pay it, but thought I would ask first if anyone knows of someone who repairs these original units on an exchange basis?

Please try the request again. I disassembled the drive ( after the power had drained off ) did not see any obvious signs of damaged or cracked components. they require a core for everything , which they refund half the cost for. Through Spindle Coolant and M4 Waylube pump issues Haas Trade in?

This can cause the 112 alarm. It took about 3 minutes to run one. If the option was purchased and the parameter bit is 0 enter the...Page 21153 96-0284 rev G June 2009Alarms402 POSSIBLE CORRUPTED FILE - Parameters being loaded do not match expected parameters. Neither show any shorts to ground.

This alarm you cannot reset. Engines Musical Instrument Design and Construction Jet Engines and Ram Jets Parts for Radio Control Models RC Robotics and Autonomous Robots Steam Engines Stirling Engines Teachers and Students Student Hangout Teachers Us...Page 26158 96-0284 rev G June 2009Alarms522 ILLEGAL ASSIGNMENT VAR OR VALUE - A variable was referenced for writing. Haas machine restore 1/8 Pipe Threads Grounding machines to Earth?

It sounds like replacement of this little unit might be the solution? ARB Reply With Quote 10-07-2005,05:13 PM #20 HuFlungDung View Profile View Forum Posts Visit Homepage Diamond Join Date Jan 2005 Country CANADA State/Province Saskatchewan Posts 8,160 Post Thanks / Like Likes Section 3Symptom: Alarm 292 HIGH VOLTAGE POWER SUPPLY FAULT, and Alarm 647 REGEN LOAD SHORTEDPossible Cause: There is a problem with the REGEN.Corrective Action: Measure the resistance across the REGEN leadsDisconnect Forum New Posts FAQ Calendar Forum Actions Mark Forums Read Quick Links Today's Posts View Site Leaders Thanks / Like Statistics Hottest Threads / Posts Forum Manufacturing Today CNC Machining Haas

It may also indicate faulty memory hardware or lost memory. Should be in stock and not too much $$. Greetings all, Just took delivery on a used 2000 Haas VF3 with Vector drive. ST30Y Tailstock Jog Brush style 4th axis on brushless machine machining off the table Haas VF2 Gearbox Lube HAAS VF series mill tramp oil separator HAAS VF4 Tool Designation Help Parting

The reading must be as follows: 2-resistor box: between 9.5 and 12.5 ohms. 3-resistor box: between 6.3 and 8.3 ohms ohms. (As shown in the illustration.) 4-resistor box: between 4.6 and Jog A-axis to withi...Page 43175 96-0284 rev G June 2009Alarms952 (M) APC-MISLOCATED LIFT FRAME - Pallet changer lift frame is not in expected position. The machine has to be powered off then on to go away. In the “diagnostics vector bits” the spindle fault shows 1.

Ensure t...Page 42174 96-0284 rev G June 2009Alarms943 (M) UNPROCESSED QUEUE CELL IN TOOL CHANGE - There is an unknown command generated in the Tool change. A WORD OF CAUTION FOR EVERYONE --- The 325 v power supply bleeds down very slowly, many minutes, after power is turned off. The servos will be turned off...Page 36168 96-0284 rev G June 2009Alarms716 (L) Ss SERVO OVERLOAD MOCON2 - Excessive load on Ss-axis motor. The machine was working normally last night when I shut down.

Parameters The parameters are incorrect. Can be caused by running a short distance into a mechanical stop. Measure the resistance across the leads. Our 1993 VF2 has a chain coupled weight for counterbalance.

What's New? The Drive DC Buss voltage is 330 which agrees withing a few volts of what the controller says the voltage is. The J3 connector is on the bottom side of the vector drive.If the parameters are correct and there is not a problem with the J3 connector on the vector drive, then It operates from analog signals sent by the Maincon or MOCON.

M. The normal message is the "Servos are off". OK Register Forum Login Help Largest Manufacturing Technology Community On The Web HOME FORUM Articles Videos Search Search Forum Discussions Search Articles & Videos Search Entire Site ADVERTISE CONTACT US Register