freenas ups error code 1 Sellers South Carolina

Computer Repair Mobile device Repairs

Address 109 Gapway St, Mullins, SC 29574
Phone (843) 636-8908
Website Link
Hours

freenas ups error code 1 Sellers, South Carolina

Auxiliary parameters must for some reason be left empty. Apr 26 23:56:52 Datengrab freenas: Starting nut_upslog. Only server in rack is the Dell 6) Monitoring system remote but corresponds with the local servers uptime –Chris Nov 17 '14 at 14:54 @Kondybas Yes, this is a Regards, Angel phillxnet (Philip Guyton) 2016-06-14 13:39:39 UTC #6 @AngeleToR Thanks for the update and testing.

How to handle a senior developer diva who seems unaware that his skills are obsolete? Also added data migration (r13315) to keep previous behavior since r13314, or else the driver will be empty in UPS screen. FreeNAS 0.7.2.5872 works perfectly. not sure of the other.

As for the pkg_add, did your remove the old nut first? but the fix has not been added to 8.0.4-p3 yet... May 15 21:49:29 Datengrab freenasr2109: Executing: /bin/pgrep -F /var/db/nut/upsd.pid upsd and nicely communicates May 15 21:51:04 Datengrab upsmonr2949: UPS ups on battery May 15 21:52:29 Datengrab upsmonr2949: UPS ups on line UPS is APC brand, working perfectly in freeNAS before.

I didn't find anything concerning changes in devfs rules in the changelog for 8.0.4-p1, so I assume that it hasn't been fixed yet? (didn't find anything in changelog for 8.0.3-p1 to Can't uu_lock cuau0: creat error: Permission denied doesn't refer to a problem accessing the serial port, but to permission error on writing the lock file. However I would not recommend your advise on using the nut user as it is still potentially a security risk. Apr 27 00:02:56 Datengrab freenas: Starting nut_upslog.

ProtoSD, Oct 10, 2011 #10 McBrian Newbie Joined: Oct 4, 2011 Messages: 14 Thanks Received: 0 Trophy Points: 4 Ok I've been doing some more testing. A couple extra lines in the docs so we users don't get strayed and that's it. just tell me what information is needed, I will try get it for the 8.0.3-p1 and a non-working version 8.0.4(-p1) I thought the information that it broke in the step from This made me wonder if this was time related but it is still failing as before with ntpd running and keeping the time correct.) #17 Updated by Zach Brown 3 months

Also using a system user very much blurs the distinction when in fact it is used completely independently, hence the suggested 'monuser' example for those that are not aware of this. The NUT system makes no assumption that this nut user requested during config is a system user and there is better separation if it is not a system user. UPS model: APC Back-UPS CS 650 OS: FreeNAS 8.0.1 Release Settings FreeNAS: Driver: APC Back-UPS USB USB (usbhid-ups) Port: /dev/ugen0.2 Log: Code: freenas: Using subdriver: APC HID 0.93 freenas: Network UPS Upgrade your server's firmware.

Tagged with: EasyNext FAQ: How To Find Hard Disk SATA Link Speed On FreeBSDPrevious FAQ: How To Find Out HP Network Printer Serial Number Remotely Using Bash Shell On Linux or Using "novendor" disconnects the UPS from the server. freenas: Starting nut_upsmon. If you have a focus for your spell casting do you need to pay materials?

Is 8:44PM 0:00.00 /usr/local/bin/upslog -s [email protected] -l /var/log/ups.log -i 300 root 1862 0.0 0.0 12040 2528 ?? Finally some progress! Join them; it only takes a minute: Sign up Here's how it works: Anybody can ask a question Anybody can answer The best answers are voted up and rise to the Using "port=auto" alone doesn't change anything.

Otherwise the nut user would have to coincide with that of the other systems involved. Anyone? It was fixed in the trunk builds but I can't say if it was fixed in the branches build (sorry Protosd, haven't tried your build on my real machine, just VM) At next reboot you can find out a reason.

On a couple of occasions, I have been alerted to the fact that the server is down by our monitoring systems. If you would like to refer to this comment somewhere else in this project, copy and paste the following link: SourceForge Robot - 2008-11-26 This Tracker item was closed automatically by We're sorry for the confusion, but this isthe 'upsdrvctl' wrapper, not the driver you're interested in. Any other suggestions? *Dell PowerEdge T20, Xeon E3-1285L v3 3.1GHz (3.9GHz Turbo) 65W TDP, 32GB DDR3L-1600 ECC RAM, Dell 80 PLUS Gold 365W PSU, Intel I350-T2 2-port NIC, LSI 9211-8i HBA

usbhid-ups stored which any number use. Possible values support-level a number from 1 to 5 device-type ups for uninterruptible power supply pdu for power distribution unit psu for power supply unit scd for solar controller From this we have: Network UPS Tools (NUT) - Rockstor's implementation ... Page 1 of 4 1 2 3 4 Next > McBrian Newbie Joined: Oct 4, 2011 Messages: 14 Thanks Received: 0 Trophy Points: 4 I'm having problems connecting my UPS to

Please refer to our Privacy Policy or Contact Us for more details You seem to have CSS turned off. The user entered in the NUT configs is just for NUT to NUT authentication which comes in more when you have a NUT server and client arrangement across the network, but That code is in no way tested yet, so make a backup and be ready to rollback if anything. #15 Updated by Alexander Motin 6 months ago OK, not next nightly Ok, thanks for the feedback, happy hacking!

And then I will require a timeout McBrian, Oct 10, 2011 #15 joeschmuck Old Man Moderator Joined: May 28, 2011 Messages: 5,154 Thanks Received: 565 Trophy Points: 111 Occupation: Electrical Skip to content Quick links N4F wiki The team FAQ Login Register Board index SERVICES UPS Latest News2016-10-07: NAS4Free 10.3.0.3.2987 - released!We really need "Your" help on NAS4Free https://translations.launchpad.net/nas4free/trunk/+pots/nas4free translations. Thanks, Torbjorn History #1 Updated by Alexander Motin 7 months ago Status changed from Unscreened to Investigation Connected and configured my APC Smart-UPS 1000 XL. Status:3rd party to resolveStart date:03/28/2016Priority:Nice to haveDue date:Assignee:Alexander Motin% Done:0%Category:UPSTarget version:- Seen in:9.10-STABLE-201603252134 Hardware Configuration:APC BE550G Back-UPS ES ESXI USB pass-through ChangeLog Entry: Description I have an APC UPS that was

You may try to experiment with not rebooting the system, but unplugging/replugging the cable or even running `usbconfig -d ugen0.4 reset`, or the last with "power_off"/"power_on" commands. #8 Updated by Torbjorn I did not go as far as shutting down yet, but it seems that UPS is seen.But Code: Select allroot: Unknown USB device: vendor 0x0764 product 0x0501 bus uhub3 keeps showing phillxnet (Philip Guyton) 2016-06-13 19:08:55 UTC #4 @AngeleToR Thanks for the update and glad you got it going, well done. Hope this helps and let us know how you get on with this, I have a couple of APC devices here that use different drives from one another but they are

It regressed in r10022. asked 1 year ago viewed 1300 times active 1 year ago Related 1Configuring power outage shutdown via APC UPS's0GE NetPRO UPS monitoring software available for Windows Server 2008?6Server power supply failures?0Redundant Home Categories FAQ/Guidelines Terms of Service Privacy Policy Powered by Discourse, best viewed with JavaScript enabled Home Blog Wiki Shop Network UPS Tools Power Devices support Home Download Related projects Compatibility Associated revisions Revision 23978662 Added by William Grzybowski over 3 years ago Remember what UPS name was chosen Submitted by: paleoNticket: #1544 Revision 4a7457a6 Added by William Grzybowski over 3 years

Also i'm told in the Port field that "auto" will work, but have you tried "/dev/usb0"? Everything works fine, so I really recommend doing it your way. That is likely required to be updated during build time. -Mark P.S. And you know I'm happy when I'm hacking.