Experimac is your local trusted tech source, specializing in Apple® product repairs and upgrades, pre-owned sales and trade-ins for; iPhone® devices, iPad® tablets, iMac® computers, MacBook® laptops and more. Experimac performs repairs on out of warranty Apple computers and other devices including upgrading Macintosh computers with higher capacity storage, installing more memory (RAM), replacing logic boards, and performing just about any other Apple repair that you may need done. We offer a 90-day warranty on all repairs and stock only the highest quality parts.

iPhone® devices, iPad® tablets, Mac® computers, MacBook® laptops, Apple® product repairs, Apple® product upgrades, Apple® pre-owned sales, Apple®, trade-ins, iPhone® repair

Address 10149 Two Notch Rd Ste C, Columbia, SC 29229
Phone (803) 401-5588
Website Link http://experimac.com
Hours

fiberlink error codes Lugoff, South Carolina

The alarms should give you something to test.. media-module and circuit-pack hardware is not required to remove programming. MB ....Telephony provides the path for the future........ int i, sn, socket__size; socket__size » 32000; /* Open socket „ */ sn = socket (AF_INET, SOCK_STREAM, 0) ; /* Set send and receive socket size c */ i - setsockopt

Join UsClose This site is intended for health professionals. The only way to measure a live > > error count > > > is to run some kind of OAM channel and to pass test frames over it. > > The optic transceivers transmit data to and receive data from the optic fi- ber. Board Number: Port: Category: Extension: Trunk ( group/member ): / mark b [US NAVY/US Air Force] RE: Intermittent Mj/Mn fiber link alarm July 18, 2013 03:05 PM

I recall logging into it to try and set the server time, but don't recall exactly *how* I did it, now. Registration on or use of this site constitutes acceptance of our Privacy Policy. ERROR TYPES Error Type: Error List: cleared-errors REPORT PERIOD Interval: a From: / / : To: / / : Alsothe 300A is a long haul lightwave transceiver. All rights reserved.Unauthorized reproduction or linking forbidden without expressed written permission.

mark b [US NAVY/US Air Force] RE: Intermittent Mj/Mn fiber link alarm July 22, 2013 07:58 AM (in response to mark b) In Reply to mark blayer: I did that and I'm convinced there is a larger issue, given the inability to remove SNI cards from software and the connection issues with the SNC. After doing all of this, you should be able to remove programming for SNI, DS1c, EI, epn hardware that has all programming removed, stations, trunks, fibers, etc. All stations and station boards have been removed from both EPNs, the only cards left are the expansion interface, test/maint and call classifier boards.

Without those your just guessing and replacing packs and transceivers in the dark. What effect will a reset or reseating of the SNI board have on the cabinet or the switch as a whole? It may contain errors or omissions that only a trained individual may recognize. ES V, ES V Series, ES V Series Workstations, ES/os, ES/Dnet, ES/PEX, ES/PHIGS, ES/PSX, Clean-Line, Fiber Link, Local Server, CDRS, and Shadowfax are trademarks of Evans & Sutherland Computer Corporation.

display alarms Page 1 of 1 ALARM REPORT The following options control which alarms will be displayed. What (if any) affect would resetting those SNI cards have on the system other than interrupting trunk calls and any calls terminating to stations served from cards in the PPN cabinet? MB ....Telephony provides the path for the future........ We replaced the sni and ei and then both transcievers--issue resolved after a while and now it has come back.

I could load xln1 on s8700 server and change programming that you need to see if there may be some type problem the servicing company will not be able to do. For example, keyfddi netmask OxffffffOO broadcast 220.123.045.0 4) If you need to set the FDDI Ring Parameters, obtain the values from your network manager. Posting Guidelines Promoting, selling, recruiting, coursework and thesis posting is forbidden.Tek-Tips Posting Policies Jobs Jobs from Indeed What: Where: jobs by Link To This Forum! I restored the fiber link for 01E19 in an attempt to clear errors.

These chips implement the FDDI protocol and manage the packet memory. We all > > > > have product > > > > responsibility; as a result, reliability and customer satisfaction are > > > > always the first priority. Unused SNI boards are physically removed, but list-config still shows them in the carrier and change circuit packs will not let me delete them, it returns "cannot delete a card that MB ....Telephony provides the path for the future........

A great teacher, does not provide answers, but methods to teach others "How and where to find the answers" bsh 40 years Bell, AT&T, Lucent, Avaya Tier 3 for 30 years RE: Urgent help needed - EPN removal / PNC problem AvayaTier3 (TechnicalUser) 20 Dec 13 18:54 remove fiber 3 remove fiber 5 change circuit-pack 3 (blank out all boards) change circuit-pack I was able to clear the error by doing a reset on individual SNI cards. Does the same hold true for an un-duplicated one?

n Resolved? LAT Host Services, DEPICT, and PCONFIG are trademarks of Ki Research. The following code fragment is used to set the buffer sizes. Fiber Link User's Manual [2.0] 2 - 1 Installation Instructions r Increasing TCP Performance V.

The intent of this note is to show how the PHY layer may be much more adept at making "bad media" determinations: 1) The rate of CRC error is traffic dependent This may be what you need to do. Procedures to follow in the field? Tips for preparing a search: Keep it simple - don't use too many different parameters.

Command: busyout fib 3 Command: rem fib 3 Command: cha cir 3 Response: no cards seen after removal of fiber. Close Reply To This Thread Posting in the Tek-Tips forums is a member-only feature. For example, if your node name is keyhole, your alias might be keyf ddl. 3) Make a new file called /etc/local_f ddl_hostname. Set switch-node clock 01E10 did *NOT* work.

This memory can also be accessed by the node processor. All SNI cards show SN-CONF error 6005: Link does not exist to SNC (Aux data is "0") Several SNI cards show SN-CONF error 6001: No neighbor link exists between SNI and Mike Jones [LSU Health Sciences Center] RE: Intermittent Mj/Mn fiber link alarm June 28, 2013 09:08 AM (in response to mark b) How far is it to the EPN? Available Categories Select a category to browse .

y Major? Also, issuing 'stat sys location' for the various SNI cards shows a major alarm with one or the other PPN SNI card. y Warning? Please note that I'm not promoting 8B/10B coding for 10 GbE since MAS uses is own more efficient coding.

mark b [US NAVY/US Air Force] RE: Intermittent Mj/Mn fiber link alarm June 24, 2013 02:18 PM (in response to Mike Jones) Mike, The problem is it does not give Email Password Forgot your password? I was unable to log into the IE access - not sure why. For best results, use the separate Authors field to search for author names.

To resolve this error, refer to FAIL code 112 for the Configuration Audit test (#759). <--- is this for the SNC board or the SNI board? Why foggy? Close this window and log in. LEDO is at the bottom and LED7 is at the top.

The system returned: (22) Invalid argument The remote host or network may be down. Two IPSI boards in each PPN cabinet. Everything that I have read on this says to not use over a 17db loss. Motif is a trademark of the Open Software Foundation, Inc.

Unseated 01E19, was able to remove in cha cir 1 Busyout/remove fib 5 Unseated 01E18, removed in cha cir 1 Seated 01E14 and 01E20, then removed. I > realize that this assumption may be incorrect since I haven't been involved > with Ethernet bridging/switching in a while. Cancel Red Flag SubmittedThank you for helping keep Tek-Tips Forums free from inappropriate posts.The Tek-Tips staff will check this out and take appropriate action.