The Q is once an error like this occurs would an approach like this save me from further issues does anyone have experience doing something similar to recover from a VISA Actually, I was thinking of supressing this error message because in the error prompt if I click on continue it runs for a while again. Share this post Link to post Share on other sites spaghetti_developer 2 Very Active Members 2 111 posts Location:Lainate Version:LabVIEW 2010 Since:2004 Posted August 28, 2009 If it's a timing Also, what you could do, is in the VI, get rid of the initialization VI, and just pass the Com port through as a constant.

mr.tuto Member ‎06-20-2007 04:07 AM Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report to a Moderator hi ananda,im getting this error too, Framing error can be detected by setting parity bit. Or sign in with one of these services Sign in with Facebook Sign in with Twitter Sign in with LinkedIn Sign Up All Content All Content This Topic This Forum Advanced A better solution is to set the VISA parameters using the "VISA Configure Serial Port" function, located on the serial palette under VISA.

It's easier than LabVIEW programming. More data might be available. 0 Kudos Message 5 of 7 (22,611 Views) Reply 0 Kudos Re: VISA: (Hex 0xBFFF006B) A framing error occurred during transfer. All of these doesn't work. Share this post Link to post Share on other sites Shaun Hayward 30 Very Active Members 30 150 posts Location:Boston, MA, USA Version:LabVIEW 2013 Since:2003 Posted August 24, 2009 I

It will not popup the error, but clear it instead. Yes that post is old but I work across LV versions and there only has to be one version that is buggy for me to adapt my rules. Or is that the amount of free memory? So, somehow if i can supress the error I think I will be fine.

I wonder if the problem could be noise due to a long cable (the infrared-RS232 adapter that I ordered with the thermistor is several feet long) and/or a cheap RS232-USB converter From: MissyD Date: Mon, 6 Mar 2006 22:40:52 -0600 (CST) Hi Ananda, I found a KnowledgeBase that discusses how to eliminate this framing error. (It lists the error in decimal You may need to read the serial buffer more than once before its empty. There is not too much I can do about it regarding the connections or the fact that it is going through a USB- Serial converter (Its on a laptop) I am

i've also try all the possible baud rates. Can anyone tell me why? You may lose some data in the process. Share this post Link to post Share on other sites Create an account or sign in to comment You need to be a member in order to leave a comment Create

Can you let me know if this helps? Sorry to all for my bad eanglish. Mark Share this post Link to post Share on other sites Grampa_of_Oliva_n_Eden 89 Prepper Members 89 2,767 posts Version:LabVIEW 2009 Since:2009 Posted March 10, 2009 Results of over- the week-end Attachments: Report Date: 01/27/2005 Last Updated: 01/22/2015 Document ID: 3HQH5B40 Your Feedback!

Then, by using a VISA Flush I/O Buffer VI, you can clear any invalid data in the buffer. It will supress the popup window when you specify the exception action as "cancel error on match". For some  reason the default setting causes the serial port settings to revert  to VISA defaults (n.b. A list of error code is also given in LabVIEW help.

When last i looked there where about 1K bytes allocated for every opean which were NOT released until after LV shutdown for every open opeation. For who want to try to read the ticket, this is the address: http://forums.ni.com...message.id=2065 but it is in italian. Do you also keep ythe default (4096) buffer size? What was happening was that any call to read/write to the serial port  would open a VISA session with the access mode set to VISA defaults,  not MAX defaults.

When I was running a USB->RS232 adapter at a higher baud rate than it actually supported, and didn't realize it. For who want to try to read the ticket, this is the address: http://forums.ni.com/ni/board/message?board.id=7170&message.id=2065 but it is in italian. Trust me I am not dissagree with you even if I do not know full answer. Internally, we now stick to a particular chipset that we have found to be the most reliable because overall its just less headache. (in our experience has been that the FTDI

The settings in hyperterminal is:Bits per second: 9600Data bits: 8Parity: NoneStop bits: 1Flow control: Noneand i used the same setting in Labview. A framing error occurs when a byte of data is start receiving at wrong starting point or not in the format expected. Or sign in with one of these services Sign in with Facebook Sign in with Twitter Sign in with LinkedIn Sign Up All Content All Content This Topic This Forum Advanced Related Links: KnowledgeBase 0Q0H595Q: Can VISA Communicate with Parallel Ports?KnowledgeBase 18QGBH0O: Setting Individual Bits for the Parallel Data Port Using LabVIEWKnowledgeBase 3B8H2CL6: How Can I Verify That My Parallel Port is

My Profile | RSS | Privacy | Legal | Contact NI © 2014 National Instruments Corporation. For reasons I don't understand it was ok if the  serial settings had just been defined, but not when another vi which  used BusCommand.vi was unloaded from memory (say a subpanel I'm still thinking about how to modify this appropriately...Also, I am not sure what you mean by "(use a delay to avoid to use 100 of the CPU to do "nothing")". Share this post Link to post Share on other sites ShaunR 694 LabVIEW Archetype Members 694 3,469 posts Version:LabVIEW 2009 Since:1994 Posted August 26, 2009 (edited) I'm sorry to All,

If your device is spewing data at a hight rate and you think there would be data in the serial ports hardware buffer then the Flush will take care of that. But, I don't understand why this happen for normal RS232 pc port and don't happen with FTDI USB converter. I don't agree with this. This VI acquires data from a thermistor that has an infrared-RS232 (9 pin) adapter, which in turns plugs into an RS232-USB converter cable (because my laptop does not have a 9-pin

The solution was to try a different (and usually more expensive) adapter. If i were to copy the example VI that you directed me to from Dennis, I would need to stop the while loop after, and only after, the "true" case has Whenever i Run LabVIEW, it will display this error message: Error - 1073807253 occurred at VISA Read in Basic Serial Write and Read.viPossible reason(s):VISA: (Hex 0xBFFF006B) A Framing error occurred during transfer. Under This can be wire-run too long, external noise, bad grounds etc.

Please Contact NI for all product and support inquiries. Share this post Link to post Share on other sites Grampa_of_Oliva_n_Eden 89 Prepper Members 89 2,767 posts Version:LabVIEW 2009 Since:2009 Posted March 7, 2009 QUOTE (TG @ Mar 6 2009, Ben Share this post Link to post Share on other sites crelf 274 I'm a LAVA, not a fighter. So far it holding so that issue may have been fixed.

You say simply clearing the buffer works and no side effects? Following the information I found in a forum search (this seems to be a very common problem!) and a KB article, I checked the port settings (baud rate, number of data Plz tell me. Take care, Ben Share this post Link to post Share on other sites Create an account or sign in to comment You need to be a member in order to leave

Each byte has a specific format with a start bit, data bits, parity, and stop bits as shown below. Maybe more than one issue but focus on serial.