gas valve circuit error Van Buren, Ohio

The control will leave the inducer energized indefinitely as long as the call for heat remains and the pressure switch is open.Pressure switch is closed before inducer is energized.Call for Heat Check all thermal switches (high limit) and reset them if any are tripped. The infuser started up and the surface ignitor started glowing, just as it always should, but for some reason, the gas valve was not letting gas in. The furnace will lock out for one hour and then restart. 7 RED FLASHES: This fault code indicates that the flame could not be established.

If it gets 24 volts and the valve does not open [ and the valve has between 4.5 and 9 inches of water column inlet pressure ] then the valve is Just dumb. Keep in mind these trip for a reson and saftey should be your main concern. Every Trane furnace has a blinking light on the control panel.

Register Help Remember Me? Repair guy replaced the 650.00 motor twice and still no heat? Finally today they put a new furnace in and the same thing is happening. This condition may be caused by: dirty filter, improperly sized duct system, incorrect blower speed setting, incorrect firing rate or faulty blower motor. 5 RED FLASHES: This fault is indicated if

The furnace will lock out for one hour and then restart. 9 RED FLASHES: Indicates reversed line voltage polarity or grounding problem. Wird verarbeitet... If after 3 attempts to re ignite is unsuccessful, “lock out mode” will remain in place for one-hour. I turned off the Air Handler breaker, installed a new 5 amp fuse, and as soon as I turned the breaker back on, the fuse blew again.

CLICK HERE AND JOIN OUR COMMUNITY TODAY...IT'S FREE! Interpret one LED flash that blinks on and off to mean your furnace has locked out because it could not ignite after three tries, and must be reset. Anmelden Teilen Mehr Melden Möchtest du dieses Video melden? This could happen with a coated flame sensor or a lazy flame from poor gas pressure.

Forums | Articles | Home Repair | Home Improvement | Painting | Interior Decorating | Remodeling | Landscaping Blogs Recent Entries Best Entries Best Blogs Blog List Search Blogs DIY About UsTell FriendsHow to AskHow to VolunteerFAQTech SupportTop ExpertsExpert LoginBrowse Answers:By CategoryAlphabeticallyFind expert answers to:Find This site uses cookies. The control will do a soft lockout, but will still respond to open limit and flame. Automotive Boats Building Construction - Existing Home Computers & Data Wiring Electrical - Existing Home WIRING DONE RIGHT Electrical = Industrial / Commercial/Power Distribution Energy Savings & Envelope Blanket of Structure

If flame is sensed longer than 4 seconds while the gas valve is de-energized, the control shall energize the induced draft motor and indoor blower motor on heat speed. Thread Tools Display Modes 01-01-2012, 12:04 PM #1 Jgolden Newbie Join Date: Jan 2012 Posts: 3 Rewards Points: 10 View Jgolden's Album Gas valve circuit error-furnace I have an Open limit and undesired flame response are still operational. Check gas valve and gas valve wiring. 11 RED FLASHES: This indicates that a primary or auxiliary limit switch has opened its normally-closed contacts and has remained open for more than

My husband just tried it again and it worked but within 10 seconds it shut off again. Breaking down each color, and number of flashes, will help you solve the problem you are having with your York Furnace.Amber/Yellow Colored Error CodeIf you see 1 amber/yellow flash, this means I get the blinking red LED right away blinking seven times. Check and clean filters, tighten wiring and check the flue for blockages.6.

Fixed that, replaced the fuse in the XR80, turned on the breaker and SUCCESS!! It's usually two flashes, then a pause, or three flashes, then a pause, etc. Now, neither cool nor heat comes on. Steven says: March 11, 2016 at 3:33 am David Allred i have a trane xe-80… it starts up blows heat for 5 min.

maybe if you trace the wires from the gas valve back and see if they stop anywhere on the way back to the board while I keep looking. I can get you more info then. We narrowed it down to having a faulty gas valve. Way to go Trane…morons!!!!

With a steddy blinking night then it blows out cold air with a 4 blinks and a pause 4 blinks… do you maybe some pointers… Thanks Steven William says: September 29, See if you can locate a device like the one in the photo, it's about the size of a quarter. What you have described sounds exactly like a dirty flame sensor as the others have instructed you to clean. __________________ IT IS WHAT IT IS 01-01-2012, 12:59 PM #6 Some models may have different different codes but these are common.

Both heating and cooling operations will be affected. When my furnace was doing that, I not only had a valve at the furnace, but at floor level where it entered into the house in a different room. (I live The control will operate the supply airblower and inducer. So in this article, you'll learn how to troubleshoot a gas furnace.

So, I don't know if you have a volt meter and know how to use it, but that is going to be the next steps. Thank you Reply With Quote February 19th, 2012,11:23 AM #5 acer66 View Profile View Forum Posts Private Message View Blog Entries View Articles Senior Member Join Date Jun 2005 Location Earth