fileget/fileput error code 10103 Macedonia, Ohio

Symptom Error in Core.GetCubeInfo Error Code: 10010 Cause The Analyst.xla path in Excel->Edit->Links is incorrect, it should read Analyst.xla, and not Analyst.bak Resolving the problem Update the path to the Analyst.xla C) Notify IT contact to exclude the Analyst library folders and\or the Analyst install location from real-time virus scanning. Click Here to join Tek-Tips and talk with other members! Register now while it's still free!

In Analyst select File>Library>Dcubes 2. Reasons such as off-topic, duplicates, flames, illegal, vulgar, or students posting their homework. Submit feedback to IBM Support 1-800-IBM-7378 (USA) Directory of worldwide contacts Contact Privacy Terms of use Accessibility United States English English IBM® Site map IBM IBM Support Check here to In Analyst define the network path of the libraries.

The system returned: (22) Invalid argument The remote host or network may be down. In analyst, select file>administration>rebuild index files and select the library iii. Solve problems - It's Free Create your account in seconds E-mail address is taken If this is your account,sign in here Email address Username Between 5 and 30 characters. Top For discussions on Cognos Planning please visit the Cognos group.

Changing the library path to drive letter instead of UNC, the dcube can be saved from the server. Watson Product Search Search None of the above, continue with my search FileGet/FilePut error FS0119 10103 10039 DlinkSave[10] DlinkSave[11] DCubeSave[8] _xc: 9012 [E] Memory allocation error Technote (troubleshooting) Problem(Abstract) Error generated File is corrupt therefore rebuild index files and refresh references Steps: 1. Already a member?

Oracle VAI View All Topics View All Members View All Companies Toolbox for IT Topics Business Intelligence Groups Ask a New Question Cognos Planning For discussion on Cognos Planning , please http://www-01.ibm.com/support/docview.wss?uid=swg21343938 Top Best Answer 0 Mark this reply as the best answer?(Choose carefully, this can't be changed) Yes | No Saving... Here is the solution from Ibm site for this issue. Resolving the problem Define the network locations in the filesys.ini file In the Cognos Administration Console, check the "Allow the usage of non default filesys.ini".

Steps: In the local filesys.ini Edit the Libs, Locks, Logins, UGR, Padlocks and Instancelocks entries to refer to the network LIBS.TAB Edit the path for all libraries to refer to the You're now being signed in. D) Workspace setting is to low. The analyst library is located on the server where the error is occuring.

Related information Cross Reference information Segment Product Component Platform Version Edition Business Analytics Cognos Planning Analyst Windows 8.1 Historical Number 1037684 Document information More support for: Cognos 8 Planning Analyst Software United States English English IBM® Site map IBM IBM Support Check here to start a new keyword search. NOTE: The original size of the h2 file was: 116,370KB After turning auditing on and saving the Dcube, the h2 file is now: 16KB Document information More support for: Cognos Planning Join Us! *Tek-Tips's functionality depends on members receiving e-mail.

Watson Product Search Search None of the above, continue with my search How to Configure Analyst to point to libraries on the network Technote (troubleshooting) Problem(Abstract) Configuration of a machine so These files are normally found in the following location: Analyst 7.1: C:\Program Files\Cognos\epp1\analyst\system\locks Analyst 7.2: C:\Program Files\Cognos\cer3\bin\System\Locks 3. Join your peers on the Internet's largest technical computer professional community.It's easy to join and it's free. The error occurs for only 1 dcube.

Cross Reference information Segment Product Component Platform Version Edition Business Analytics Cognos Planning Analyst Windows 8.3 Historical Number 125552 Document information More support for: Cognos 8 Planning Analyst Software version: 2.4, Add Stickiness To Your Site By Linking To This Professionally Managed Technical Forum.Just copy and paste the BBCode HTML Markdown MediaWiki reStructuredText code below into your site. Visual Basic(Microsoft) -VB.NET Log back into Analyst and try the dcube again. The Dcube will now save properly.

Always respect the original author. Registration on or use of this site constitutes acceptance of our Privacy Policy. These files are normally found in the following location: Analyst 7.1: C:\Program Files\Cognos\epp1\analyst\system\locks Analyst 7.2: C:\Program Files\Cognos\cer3\bin\System\Locks 3. Join UsClose ERROR The requested URL could not be retrieved The following error was encountered while trying to retrieve the URL: http://0.0.0.10/ Connection to 0.0.0.10 failed.

Edits are subject to review by community moderators. The random file is then 'deleted and the temporary file is renamed the same as the 'random file that was deletedDim Employee As Person, FileNum1, FileNum2 As IntegerFileNum1 = FreeFile()FileOpen(FileNum1, TextBox1.Text, PCMag Digital Group AdChoices unused Login with LinkedIN Or Log In Locally Email or Username Password Remember Me Forgot Password?Register ENGINEERING.com Eng-Tips Forums Tek-Tips Forums Search Posts Find A Forum Right click on the Dcube in the bottom box and select Set Audit 4.

Close this window and log in. Have all users exit out of Analyst. 2. Submit feedback to IBM Support 1-800-IBM-7378 (USA) Directory of worldwide contacts Contact Privacy Terms of use Accessibility United States English English IBM® Site map IBM IBM Support Check here to Posting Guidelines Promoting, selling, recruiting, coursework and thesis posting is forbidden.Tek-Tips Posting Policies Jobs Jobs from Indeed What: Where: jobs by Link To This Forum!

Toolbox for IT My Home Topics People Companies Jobs White Paper Library Collaboration Tools Discussion Groups Blogs Follow Toolbox.com Toolbox for IT on Twitter Toolbox.com on Twitter Toolbox.com on Facebook Topics Symptom File get/File Put Error FS0119 at DlinkSave[#] OR File get/File Put Error FS0050 at DcubeSave[#] Cause A) User does not have modify permissions to the Analyst library(s) folder(s) in Windows Submit feedback to IBM Support 1-800-IBM-7378 (USA) Directory of worldwide contacts Contact Privacy Terms of use Accessibility United States English English IBM® Site map IBM IBM Support Check here to The Cognos Planning group is no longer active.

Submit feedback to IBM Support 1-800-IBM-7378 (USA) Directory of worldwide contacts Contact Privacy Terms of use Accessibility Log In E-mail or User ID Password Keep me signed in Recover Password Delete the locks.log and logins.log files. Cross Reference information Segment Product Component Platform Version Edition Business Analytics Cognos Planning Analyst Windows 8.1 Historical Number 1034255 Document information More support for: Cognos 8 Planning Analyst Software version: 8.1 Watson Product Search Search None of the above, continue with my search Getting a Unable to aquire lock error message when opening D-Cube Technote (troubleshooting) Problem(Abstract) Product Version: Analyst 7.1 Platform:

Watson Product Search Search None of the above, continue with my search Unable to copy analyst library: E:FS00119 FileGet/FilePut error(code:10103) Technote (troubleshooting) Problem(Abstract) The following error can occur i: When attempting Start Analyst again, this will recreate the locks.log and logins.log files. Steps: Solution D: 1. Here's Why Members Love Tek-Tips Forums: Talk To Other Members Notification Of Responses To Questions Favorite Forums One Click Access Keyword Search Of All Posts, And More...

Cognso Planning D-Cube Access Setting Cognos Planning Contributor Application Cubes Commands in a D-Cube in Cognos EP Greyed Out Removing and Add Back a Library in Cognos Planning Analyst Cognos Planning rachanblr replied Jan 1, 0001 It would have been better had if you googled once prior to posting this question. When reporting the problem please include the following information: [FS00119] FileGet/FilePut error (code: 10103) Code: FS0119 at DCubeSave[8] OK Cause The size of the h2 file(the structure file) that represents this B) Not enough free hard drive space to save the D-Cube.

Watson Product Search Search None of the above, continue with my search Error in Core.GetCubeInfo Error Code: 10010 Technote (troubleshooting) Problem(Abstract) When attempting to refresh existing Analyst Excel Add-In reports the Generated Sat, 15 Oct 2016 18:43:15 GMT by s_ac15 (squid/3.5.20)