execio error while East Palestine Ohio

Address 16630 State Route 267, East Liverpool, OH 43920
Phone (330) 385-4115
Website Link http://www.stowerscomputerservices.com
Hours

execio error while East Palestine, Ohio

If that is the case, then REXX doesnt recognise the EXECIO as a valid DB2 command. George                                                          ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, If you know what a return code of -3 is I would appreciate it. "ALLOC DS("dsnout") DD(DDOUT) SHR REU" IF rc <> 0 THEN DO SAY "Error in OPENDSN " SAY Hello everyone, I am new to REXX and need help with a REXX routine for use to monitor my OS-390 DB2 DASD usage.

First is DSN, second is Member name, third is a string of text. MrSpock Global moderator Posts: 811Joined: Wed Jun 06, 2007 9:37 pmLocation: Raleigh NC USA Hasthanked: 0 time Beenthanked: 2 times Top Re: REXX by Halka » Fri Dec 07, 2007 OUTPUT: DATA. = oline "EXECIO 1 DISKW DDOUT (STEM DATA." IF rc <> 0 THEN DO SAY "Error in OUTPUT" SAY "Return Code = " rc EXIT END RETURN I get I am getting a return code of -3 on writing to a PDS file.

Halka Posts: 7Joined: Thu Dec 06, 2007 8:54 am Hasthanked: 0 time Beenthanked: 0 time Top Display posts from previous: All posts1 day7 days2 weeks1 month3 months6 months1 year Sort Show me the error of my ways. I am not sure how to access the REXX list serve. U will then need to reset the ADDRESS environment using the ADDRESS instruction. (If u have any difficulty, send me a copy of the code, so that I can try to

I am getting a return code of -3 on writing to a PDS file. However, since you are also using "ALLOC", you are obviously running in TSO, so you're fine. When I write in REXX, and I write a lot of Troy Coleman Coleman Consulting, Inc. ---------------- Powered by telstra.com the DB2-L webpage at http://www.ryci.com/db2-l. I needed to add the address TSO because I had changed the address to DB2.

That way, 1) there is no question about where the host command is being directed, thus the program is easier for follow-on people to understand and service and 2) I do Rob Wright Re: Rexx Question - EXECIO error -3 May 2, 2001 09:05 PM (in response to Troy Coleman) You need to change it to: data.1=oline data.0=1 The EXECIO is expecting RC8 from ERASE and TBSKIP probably is OK. OUTPUT: DATA. = oline "EXECIO 1 DISKW DDOUT (STEM DATA." IF rc <> 0 THEN DO SAY "Error in OUTPUT" SAY "Return Code = " rc EXIT END RETURN I get

Perform some logic to set oline then CALL OUTPUT ... Can you help? The string of text is the concatenation of lines delimited by a ";". (ex. "line1;line2;line3"). U will then need to reset the ADDRESS environment using the ADDRESS instruction. (If u have any difficulty, send me a copy of the code, so that I can try to

Thanks again!! However, since you are also using "ALLOC", you are obviously running in TSO, so you're fine. When I write in REXX, and I write a lot of it'll show file in use. Troy Coleman Coleman Consulting, Inc. >>> [login to unmask email] 05/02/01 10:24PM >>> Troy, U might have a misplaced ADDRESS statement in ur code.

FILE INFILE1 NOT FREED, IS NOT ALLOCATED its a very urgent requirement....... MVSFORUMS.com Forum Index -> TSO and ISPF View previous topic :: View next topic Author Message OkonitaBeginnerJoined: 29 Oct 2003Posts: 9Topics: 7 Posted: Thu Jun 23, 2005 4:37 pm Post If an example is available, that will be very very helpful. I am getting a return code of -3 on writing to a PDS file.

Treat NULLFILE as a regular data set name (be sure it resolves to being in single quotes). Not enough volumes were specified for the data set, through the SER, volume count, or REF subparameter of the VOLUME parameter of the DD statement. They mean the same thing. Further information: allocate SYSPRINT to DA(*) instead and read the messages.

I am not sure how to access the REXX list serve. If you know what a return code of -3 is I would appreciate it. "ALLOC DS("dsnout") DD(DDOUT) SHR REU" IF rc <> 0 THEN DO SAY "Error in OPENDSN " SAY IRX0255E Abend in host command EXECIO or address environment routine TSO IRX0670E EXECIO error while trying to GET or PUT a record. +++ RC(20) +++ (4) 140 *-* "ISPEXEC TBERASE DASDMON" Perform some logic to set oline then CALL OUTPUT ...

Perform some logic to set oline then CALL OUTPUT ... The request cannot be fulfilled by the server The request cannot be fulfilled by the server The request cannot be fulfilled by the server The request cannot be fulfilled by the Sometimes it will work, sometimes not. U might be having an ADDRESS DSNREXX or something in ur code.

Terms of Service | Privacy Policy | Contact×OKCancel Skip to site navigation (Press enter) Re: Rexx Execio to PDS Barkow, Eileen Mon, 26 Aug 2013 11:46:43 -0700 E37 04 means that All Rights Reserved. OUTPUT: DATA. = oline "EXECIO 1 DISKW DDOUT (STEM DATA." IF rc <> 0 THEN DO SAY "Error in OUTPUT" SAY "Return Code = " rc EXIT END RETURN I get Thanks, Tim Todd Burch ******************************************* To: [login to unmask email] ********** <[login to unmask email]> cc: Sent by: DB2 Data Base Discussion List Subject: Re: Rexx Question - EXECIO error -3

MVS OS reports the error as follows: IEC036I 002-04,IGC0005E,AO11063V,ISPFBTCH,OUTDS, 7C05, SYSDA6,SYS05174.T160036.RA000.AO11063V.R0261902 Please let me know if you need additional information. Also, check ALLOC command in TSO regarding DUMMY files. FINIS"   "FREE F(Pdsout)"   Return                                                                Failure: The dsname is: :HLQ.TEST(MEM3): Number of lines written: 3 ACC20210-A ADDVOL FOR DD=PDSOUT DSN=HLQ.TEST VOL=S92248 POOL=TSOPOOL EXT=16 ACC20628-A DATA SET IS PARTITIONED System abend Once the small stuff like this is understood, using MVS can become rather fun.

If that is the case, then REXX doesnt recognise the EXECIO as a valid DB2 command. Abend in host command EXECIO or address environment routine TSO. If you know what a return code of -3 is I would appreciate it. "ALLOC DS("dsnout") DD(DDOUT) SHR REU" IF rc <> 0 THEN DO SAY "Error in OPENDSN " SAY The problem is I'm getting the error FILE INFILE1 IS NOT FREED.

FINIS" IRX0250E System abend code 002, reason code 00000004. If this is foreground, you need to add a LIBDEF for ISPPLIB. Further Information: ISPF Services Guide PANEL NOT FOUND: If this is batch, your JCL probably has the wrong libraries allocated to ISPPLIB. Further info: ISPF Developer's Guide and maybe the ISPF Customization guide IEC036I could be anything based on the previous errors, but ...

Tel: 800-627-6561 or 281-920-3305 Internet Address: [login to unmask email] Home Page: http://www.cdbsoftware.com ***************************************************** Tim Lowe Re: Rexx Question - EXECIO error -3 May 3, 2001 11:04 AM (in response to FILE INFILE1 NOT FREED, IS NOT ALLOCATED my code is DSN_NAME = 'BDLT.USTRI.REXX.SB853.TOOLS' DSNN = DSN_NAME||'('||SPACE('CPY')||')' "ALLOCATE DDN(INFILE1) DSN('"DSNN"')" /* IN THE SRCH JCL, REPLACE THE EXISTING SRCH STRING WITH USER I am having the following errors when I try to execute the REXX program: (1) ALLOC DD(SYSPRINT) DSN("NULLFILE") SHR REUSE" >>> "ALLOC DD(SYSPRINT) DSN(NULLFILE) SHR REUSE" IKJ56228I DATA SET USERID.NULLFILE NOT If you know what a return code of -3 is I would appreciate it. "ALLOC DS("dsnout") DD(DDOUT) SHR REU" IF rc <> 0 THEN DO SAY "Error in OPENDSN " SAY

You need to check what was you last ADDRESS command, or issue ADDRESS TSO just before doing EXECIO command.