flexlm error 15 10 Oriska North Dakota

Hiline Technology Solutions is a technology retailer and professional installation business.  We carry all of the top brands and custom install many of our products.  We build and install security cameras and other security devices.  We sell and install satellite services such as Directv, Dish Network, Exede Viasat Internet.  Hiline Technology Solutions is an authorized service and sales company for Lenovo, TP LINK, LG, Sharp, HP, Panasonic and many others.  We service anything electronic.  

Computer Sales & Service, LAN/WAN Network Design & Installation, Wireless Communication, Commercial Audio/Video, Home Theater Sales & Installation, Directv, Dish Network, Exede Satellite Internet Service, Century Link DSL Internet Service, Assisted Listening, PA Systems, Flat Screens, Projectors, Speakers, Cables, Cords & More!

Address 150 2nd St SW, Valley City, ND 58072
Phone (855) 845-6200
Website Link http://www.hilinetech.com
Hours

flexlm error 15 10 Oriska, North Dakota

If you do not have a port number on the end of this line, you will need to specify a port. System Error: 10061 "WinSock: Connection refused" For further information, refer to the FLEXlm End User Manual, available at "http://www.globetrotter.com". Cause for Error 2 The information in your license file may be incorrect, or you may be missing a FEATURE9.lic file. Follow steps 4 and 5 in the following guide: Quick Start: Setting up a license server on Windows Products: AutoCAD Design Suite;AutoCAD;AutoCAD Architecture;AutoCAD Civil 3D;AutoCAD Electrical;Design Academy;Entertainment Creation Suite;Infrastructure Design Suite;Inventor;AutoCAD

Check the paths and spelling of the licenses listed in the "license path" indicated in the error message. 2.) PROBLEM: The server machine specified in the license file is down; SOLUTION: Again, this must be a free port on the machine. These drivers are available at www.macrovision.com or from your software vendor. -113 Two FLEXlock checkouts attempted. System Error: 10038 "Winsock: Specified socket is invalid"or FLEXlm error: -15,570.

If this fails to allow the client to access the server, try using the license server's IP address instead of the fully qualified domain name in the above environment variable. more » NEW ENVI Pocket Guide Vol. 1 | Basics An ENVI quick reference booklet that provides users succinct steps on how to accomplish common tasks in ENVI. Related Articles AutoCAD Forum Connect with peers and Autodesk in our forums, read community articles, and submit your ideas. E.1.1 Format 1 (short): FLEXlm error text (-lm_errno, minor_num[:sys_errno]) [sys_error_text] The system error information may be missing.

SOLUTION: Make sure that port 1700 is opened for TCP communication through any firewall that is enabled on the server or client machines. Solution or Workaround First, verify that the License Path indicated in the error message is the correct host name or IP address of the license manager system. You may need administrator privileges to edit these files. 3. For example: DAEMON MLM "C:\flexlm\mlm.exe" port=1711In this example, MLM is tied to port 1711.

On the 'Start/Stop/Reread" tab, ensure the service is highlighted. 10. You may have accidentally edited your license file. Unanswered question This question has not been answered yet. FLEXlm error -15,10 "Cannot connect to license server" or "WinSock: Connection refused" Saturday, September 15, 2001 Topic: For floating license trouble shooting: Symptom: When starting a Windows IDL or other RSI

The server (lmgrd) has not been started yet, or the wrong [email protected] or license file is being used, or the port or hostname in the license file has been changed.Feature: ARC/INFOServer SOLUTION: From the client machine, try using telnet host port where host and port are the same as on the SERVER line in your license file. Submit Feedback sent successfully. External (Open), Non-Confidential Home ARM Technical Support Knowledge Articles Why am I getting a FLEXlm -15 license error, even though my license server is running?

System Error: 10061"WinSock: Connection refused." Error 2 FLEXlm Error: -15, 29. Products MATLAB Related Content 1 Answer MathWorks Support Team (view profile) 13,637 questions 13,637 answers 13,636 accepted answers Reputation: 2,607 Vote0 Link Direct link to this answer: https://www.mathworks.com/matlabcentral/answers/91576#answer_100927 Answer by MathWorks Submit feedback to IBM Support 1-800-IBM-7378 (USA) Directory of worldwide contacts Contact Privacy Terms of use Accessibility Share?Profiles ▼Communities ▼Apps ▼ Forums Rational ClearQuest Log in to participate Expanded section▼Topic Tags Also run lmdiag to get additional clues about a network related problems and how to resolve them in the context of this problem.

The system administrator has reserved all the licenses for others. Table 8-1: FLEXlm Error Codes Error Code Description -1 Cannot find license file. -2 Invalid license file syntax. -3 No server for this feature. -4 Licensed number of users already Check the 'Use Services' option. 8. The default port number is 27000 and if it is specified in one and not in the other, it might again cause the same problem.

This often happens when NIS or DNS or the hosts file is incorrect. These numbers are unique error identifiers and are used by FLEXlm vendors for more advanced support assistance. The file was issued for a later version of FLEXlm than this program understands. -91 ENCRYPTION_SEEDS are non-unique. -92 Feature removed during lmreread, or wrong SERVER line hostid. -93 This feature For ARM tools using FLEXlm versions 8.1b and older(for instance, RVCT 2.0 and ADS 1.2.x), the limit is 32 characters.

The client may not have an environment variable,ARMLMD_LICENSE_FILE, which references the license server orthe local license file. Is This Content Helpful? Topic Forum Directory >‎ Rational >‎ Forum: Rational ClearQuest >‎ Topic: FLEXlm error: -15,10. Based on your location, we recommend that you select: .

The server has pooled one or more INCREMENT lines into a single pool, and the request was made on an INCREMENT line that has been pooled. -94 Attempt to generate license Move your mouse over the bar and click Did you find this article helpful? Check the license manager debug log file that was specified when configuring the license manager. Licensing & Installation Frequently ...

Show: 10 25 50 100 items per page Previous Next Feed for this topic Toggle Main Navigation Log In Products Solutions Academia Support Community Events Contact Us How To Buy Contact Search on GeoNet Submit to ArcGIS Ideas Error: FLEXlm Error: -15 Cannot connect to license server Error Message The following error message displays when starting an ArcGIS Desktop application:"FLEXlm Error: Cannot The firewall can block requests from the client despite the server being operational. Go to the Configure Services tab. 4.

System Error: 10038 Winsock: Specified socket is invalid" when I try to start MATLAB? See section 4.2 of the ARM FLEXlm License Management Guide for more information about port numbers. These error messages may occur in two formats available with FLEXlm or may appear in a format customized by the application. The server must be restarted for options file changes to take effect. -102 A FLEXid borrow error occurred. -103 Terminal Server remote client not allowed. -104 Cannot borrow that long. -106

However, if a connection is not established this may indicate that the license manager is not running properly or that there is a network communication problem between the client and the If necessary, reboot your computer to restart the License Manager. You can also select a location from the following list: Americas Canada (English) United States (English) Europe Belgium (English) Denmark (English) Deutschland (Deutsch) España (Español) Finland (English) France (Français) Ireland (English) The lmgrd log file shows an error pertaining to different ports being specified in the license.dat files.
Cause By default, the LMTOOL.exe in Windows installation will have both 'rational_server_perm.dat' as

Social Products and Solutions Harris Geospatial Solutions Products Custom Services Geospatial Marketplace Industries Defense & Intelligence Environmental Monitoring Academic Learn Videos Blogs Events & Webinars Training Case Studies Whitepapers Resources Close × Select Your Country Choose your country to get translated content where available and see local events and offers. United States Patents Trademarks Privacy Policy Preventing Piracy Terms of Use © 1994-2016 The MathWorks, Inc. System Error: 10061 "WinSock: Connection refused" ‏2008-05-15T21:53:08Z This is the accepted answer.

Applies to: ARM Developer Suite (ADS), DS-5, RealView Development Suite (RVDS), Tool Licensing (License Management) Answer Ifyou get the following error message on your client when you try to use a C:\flexlm).If the error includes this line: ERROR: FLEXlm error: -15,570. For more information, please see the Floating License Installation document within the FAQ: How do I install my floating license? You may be missing the Sentinel SuperPro driver.

Move your mouse over the bar and click Did you find this article helpful? Products and Solutions Geospatial Products ENVI Jagwire Geiger-Mode LiDAR IDL Custom Solutions Extend ENVI & IDL Enterprise Technologies Custom Software Solutions Geospatial Marketplace Data Store Services Data Samples Industries Defense Feature: MATLAB Server Name: Server1 License path: C:\MATLAB6p5\bin\win32\license.dat;C:\MATLAB6p5\bin\win32\*.lic FLEXlm error: -15,570. MOST POPULAR How to Obtain the Host Name and Host ...

Visit the Forum Contributed By Support Need Assistance?