file status error codes in cobol Marmarth North Dakota

Address 510 1st St SW, Beach, ND 58621
Phone (701) 872-3151
Website Link
Hours

file status error codes in cobol Marmarth, North Dakota

Other Recommended Posts: Abend Codes, Entire Mainframe Materials, Mainframe, Mainframe Tips, MF Interview Question Answers Get FREE Mainframe Interview Question & Answers - Click Here Posted by M siva raman at A Job ended in a controlled manner by CL command ENDJOB, PWRDWNSYS, ENDSYS, or ENDSBS CPF4741. THE PROGRAM SHOULD BE INVOKED UNDER THE DSN COMMAND   SQLCODE  -926, Error: ROLLBACK NOT VALID IN IMS OR CICS ENVIRONMENT   SQLCODE  -925, Error: COMMIT NOT VALID IN IMS OR RT004 Illegal file name.

Template images by rajareddychadive. RT017 Record error: probably zero length. Not initializing the numeric variables before first use SB37    -   Insufficient disk space (End of volume and no further volume specified) SD37    -   Insufficient disk space. (No secondary allocation The maximum number of extents would be exceeded.

Run-time errors are documented in the chapter Run-time System Messages in your Error Messages. When using ANSI'74 or ANSI'85 file status codes, the run-time system returns extended status codes if the extended file status is more specific than what would normally be returned. Change the file size (for example, using CHGPF) to the size you expect, and submit the program again. DISPLAY '30000-TERMINATE-PARA' CLOSE OUT-FILE INFILE1 INFILE2 . 30000-EXIT.

Note:A SimoTime License is required for the items to be made available on a local system or server. The I/O statement failed because of a boundary violation. Alternatively a START or READ operation has been tried on an optional input file that is not present. 24 Relative and indexed files only. Maybe empty file opened as I-O. (Open) 91Password failure. (Open) 92File already open. (Open) File not open. (Close, Start) File not open or already at end. (Read, Read Next) File not

In the world of programming there are many ways to solve a problem. DISPLAY '22000-MATCH-DATA' DISPLAY 'FILE1 RECS READ = ' FILE1-READ. REASON   SQLCODE  -804, Error: AN ERROR WAS FOUND IN THE APPLICATION PROGRAM INPUT PARAMETERS               FOR THE SQL STATEMENT, REASON   SQLCODE  -803, Error: AN INSERTED OR UPDATED VALUE IS INVALID File Status Codes (or) COBOL Abend Codes ERROR REASON CODE 00 Operation completed successfully 02 Duplicate Key was found...

Alternate indexes are incorrectly defined (Key length or position, duplicates or sparse parameters). 2. Only for indexed files opened sequentially. (Write, Rewrite) 22Duplicate key found but not allowed. (Write, Rewrite) 23Record not found. (Read) 24Disk full. (Write, Rewrite) 24,01Sequential write to a relative file and EXIT. 21100-READ-INFILE2. The minimum record length specified by the program is less than the minimum record length required for the file.

The I-O phrase was specified but the file would not support the input and output operations permitted. RT047 Indexed structure overflow. (Could indicate that you have reached the maximum number of duplicate keys.) RT065 File locked. IMS DB/DC Return Codes The IMS return codes are listed here alphabetically, you may browse through them or you may enter the code you are looking for and press th... Many vendors take advantage of the x"00' to x'FF' (or 0-255) binary value.

File Structures File Handling Limits Chapter 15: File Status Code Tables This chapter lists all possible values that can be returned in file status. StatusKey-1Description by Group 0Successful Completion or non-terminal condition that may be acceptable to continue processing. Refer to the section for Status-Key-1 being equal to "0" for additional information based on Status-Key-2. 1End of File, attempting to read beyond the end of the file. The I/O statement was unsuccessfully executed as the result of a boundary violation for a sequential file or as the result of an I/O error, such as a data check parity

RT001 Insufficient buffer space. We reserve the right to make changes without notice at any time. A sequential WRITE operation has been tried on a relative file, but the number of significant digits in the relative record number is larger than the size of the relative key An attempt has been made to access a record identified by a key, and that record does not exist in the file.

Attempt has been made to store a record that would create a duplicate key in the indexed or relative file or a duplicate alternate record key that does not allow duplicates. Or, a sequential WRITE statement was attempted for a relative file and the number of significant digits in the relative record number was larger than the size of the relative record That error message is very general; a "permanent error" could mean that the disk has failed, or that the disk drive door is open. This does not apply to VSAM sequential files. 06 WRITE Attempted to write to a file that has been opened for INPUT. 07 CLOSE OPEN

Therefore, the file status key may not always be a numeric value that is easy to display. RT026 Block I/O error. 35 RT027 Device not available. Company Overview Founded in 1987, SimoTime Technologies is a privately owned company. Close was successful. (Close) 0MSuccessful operation but some optional feature was not used or supported. (Any) 10End of file. (Read Next) 14Attempted sequential read on a relative file and relative key

Therefore, adjustments may be needed to execute the jobs and programs when transferred to a system of a different architecture or configuration. RT032 Too many indexed files, or no such process. 30 RT033 Physical I/O error. 30 RT034 Incorrect mode or file descriptor. 37 RT035 Attempt to access a file Could also happen if the program that created the file did not explicitly close the file - especially non-sequential files. The prime record key value has been changed by the program between the successful execution of a READ statement and the execution of the next REWRITE statement for that file, or

Reading a file that is not open Your SORTIN DCB was not correct Mixing compile options RES and NORES in different modules  S0C4 An uncontrolled loop moved data on top of If you have any questions, suggestions, comments or feedback please call or send an e-mail to: [email protected] We appreciate hearing from you. Calling a program and the program was not included during link edit. Indicates a sequence error.

RT068 Record locked. Possible causes: For a READ statement, the key value for the current key is equal to the value of that same key in the next record in the current key of RT029 Attempt to delete open file. SimoTime Technologies makes no warranty or representations about the suitability of the software, documentation or learning material for any purpose.