fanuc error codes uop Harvey North Dakota

Address 100 8th St E, Harvey, ND 58341
Phone (701) 324-2999
Website Link http://dakotacomputer.com
Hours

fanuc error codes uop Harvey, North Dakota

i had the servo rebuilt just before i retired because it was acting up. Use Procedure C-1 to display the Alarm Log screen. Alarm Code #5 Excessive regenerative discharge alarm (DCOH).  Alarm occurs when average regenerative discharge energy is too high.  *Causes may include operation of thermostat for regenerative discharge resistor or thermostat between SRVO-155 SERVO DCAL(CNV) alarm (G:%d A:%d) · Cause: Refer to SRVO-043. · Remedy: Refer to SRVO-043.

S-420iR has the mark at non-zero position for J2 and J3. If the voltage is found to be 170 VAC or below, check the input power supply voltage. (A sub-standard voltage, applied to a servo amplifier results in a lower-than-normal torque. INTP-208 PAUSE.L (%s^4, %d^5) Divide by 0 · Cause: Division by 0 was executed. · Remedy: Check the value. Forum New Posts FAQ Calendar Forum Actions Mark Forums Read Quick Links Today's Posts View Site Leaders Thanks / Like Statistics Hottest Threads / Posts Forum Manufacturing Today CNC Machining Fanuc

Execution entered into a FOR loop by the GOTO statement. · Remedy: A GOTO statement cannot be used to enter or exit a FOR loop. Most Common Alarm Codes for Fanuc Servo Amplifiers (Indicated on the Status Display) Posted 18 January 2016 by Jade York in category Industrial Electronics, Servo Drives with 5 comments Most common Remove this noise such as with taking ground of sealed earth. See the description for Servo- 073 CMAL alarm.

A: Viper offers manuals for its car and home alarms in the Support section of its website, Viper.com. INTP-256 PAUSE.L (%s^4, %d^5) No data for CAL_MATRIX · Cause: The origin 3 points or destination 3 points are not taught. · Remedy: Teach the origin 3 points or destination 3 SRVO-030 SERVO Brake on hold (Group:%d) · Cause: When the temporary stop alarm function ($SCR.$BRKHOLD_ENB=1) is enabled, this alarm is issued whenever a temporary stop is made. Use Procedure C-1 to display the Alarm Log screen.

INTP-123 PAUSE.L (%s^4, %d^5) Process application data failed · Cause: An error occurred during process application. · Remedy: Refer to the error cause code. INTP-216 PAUSE.L (%s^4, %d^5) Invalid value for group number · Cause: The indicated value is invalid for the motion group number. · Remedy: Check the value. PPABN originates on axis control pcb. INTP-257 PAUSE.L (%s^4, %d^5) Invalid delay time · Cause: The wait time value is negative or exceeds the maximum value of 2147483.647 sec. · Remedy: Input a correct value.

Generally, if a servo amplifier's MCC is not turned on despite the signal for turning the MCC on having been issued, an alarm is issued for the servo amplifier. The specified value exceeds the maximum limit. · Remedy: Check the value. SRVO-038 SERVO2 Pulse mismatch (G:%d A:%d) · Cause: A pulse count detected at power-off differs from that detected at power-on. · Remedy: Contact our service center serving your locality. SRVO-044 SERVO HVAL alarm(Group:%d Axis:%d) · Cause: The DC voltage (DC link voltage) of the main circuit power supply is abnormally high.

Regards, Jade York Russell Thompson 9 months ago What does status d on my servo amp mean and how would i correct it Thanks Russell Joe 6 months ago SRVO-065 WARN BLAL alarm(Group:%d Axis:%d) · Cause: The battery voltage for the pulse coder has dropped below the allowable minimum. · Remedy: Replace the battery. (When this alarm is issued, immediately If pneumatic pressure is not used set the $PPABN_ENBL system variable to FALSE. Close the circuit breaker if it is found to be off.

Mastering is required. SRVO-047 SERVO LVAL alarm(Group:%d Axis:%d) · Cause: Despite the external magnetic contactor for a servo amplifier being on, the DC voltage (DC link voltage) of the main circuit power supply or If the robot's ratings, such as the rated duty cycle and load, are exceeded, modify the use of the robot such that the rated values are not exceeded. · Remedy: 2 SRVO-152 SERVO IPMAL(INV) alarm (G:%d A:%d) · Cause: IPM module has trouble. · Remedy: IPM might be overheated.

Learn how to troubleshoot CNC alarms and find answers for machine problems. SRVO-013 SYSTEM Srvo module config changed · Cause: The configuration of digital servo modules has changed. · Remedy: Reconfigure system with new digital servo module changes. If a short circuit is found, check the motor, robot connection cable, or robot internal cable. This KAREL statement cannot be executed. · Remedy: Check the KAREL translator software version.

Alarm codes begin with zero and rise up to 976 before skipping to 4,500 and going up to 5,450. All Rights reserved. Set the system variable $SCR_GRP.$ROBOT_MODEL correctly. SRVO-018 SERVO Brake abnormal · Cause: The FET current for brake exceeded the specification. · Remedy: Check the position of the SET jumper on the EMG Control pcb.

Use Procedure C-1 to display the Alarm Log screen. Feel free to submit a comment and join the conversation! Use Procedure C-1 to display the Alarm Log screen. PEOPLE SEARCH FOR Fanuc Operator's Manual Fanuc G Codes Fanuc Ot Alarm Codes Fanuc Programming Basic Fanuc Programming Fanuc Controls G Codes Fanuc America Fanuc CNC Tutorials Explore Q: How do

SRVO-146 SERVO LVAL(INV-DC) alarm(G:%d A:%d) · Cause: The DC voltage of the main circuit power supply is too low. · Remedy: Check each interphase voltage of the three-phase voltage (200 VAC) One can inquire with the company by phone at 1-800-458-1552, via... SRVO-144 SERVO LVAL(INV) alarm (G:%d A:%d) · Cause: Refer to SRVO-047. · Remedy: Refer to SRVO-047. Use Procedure C-1 to display the Alarm Log screen.

INTP-118 PAUSE.L (%s^4, %d^5) Walk back data request failed · Cause: An error occurred trying to obtain the execution history. · Remedy: Refer to the error cause code. See the description for Servo - 070 STBERR alarm. INTP-107 ABORT.L (%s^4, %d^5) Pause request failed · Cause: An error occurred when program execution was held. · Remedy: Refer to the error cause code. Learn more about Car Parts & Maintenance Sources: helmancnc.com fanuc-spares.co.uk fanuc.eu coe.berkeley.edu Related Questions Q: Where can you find a replacement Viper Alarm owner's manual?

INTP-303 ABORT.L (%s^4, %d^5) Specified value exceeds limit · Cause: KAREL program error.