event id 10004 dcom got error Cannon Ball North Dakota

All Nations Office & Technology is centrally located in Bismarck, North Dakota. We are a full service office supply and computer equipment company. We provide a wide range of office supplies and equipment, including furniture, computers, printers, seating, office equipment, and all your computer supplies.Our success comes from both our staff and our customers. With our combined experience of more than 20 years, we provide more than just office products. What sets us apart from our competition is our dedication to the customer. Our representatives are attentive to the needs of the customer, and provide professional service and support.Tired of paying outrageous prices to get your computer back up and running? Office & Technology is now offering in-house along with on-site computer technical support at a reasonable price. Contact us today and ask for our truly fair price for computer support, you won't be disappointed.

Address 4409 Centurion Dr, Bismarck, ND 58504
Phone (701) 221-2701
Website Link http://www.allnat.net
Hours

event id 10004 dcom got error Cannon Ball, North Dakota

This is the error (obviously, I didn't put in my account name or the domain name). Click Proceed. 5. The other thing could be that the permissions on the DCOM are not setting up properly. Recommend Us Quick Tip Connect to EventID.Net directly from the Microsoft Event Viewer!Instructions Customer services Contact usSupportTerms of Use Help & FAQ Sales FAQEventID.Net FAQ Advertise with us Articles Managing logsRecommended

once you find the matching service and string you can right click and choose properties. 6. thanks for the post. even so, if you would encounter this situation, you'll have a head start if you relate to the little guide I posted (-; Best Regards and Good Luck: Patrik Svedman - Change the logon information in the ePolicy console to the new password.

Error: Logon failure: unknown user name or bad password, GUID: 1FD7A201-0823-479C-9A4B-2C6128585168 - To resolve this problem, give the domain account the Log on as a batch job privilege in the Group The problem was caused by installing IIS on a member server, then promoting it to domain controller. Related Management Information COM Security Policy Configuration Application Server Community Additions ADD Show: Inherited Protected Print Export (0) Print Export (0) Share IN THIS ARTICLE Is this page helpful? I have admin level privelages on the network, though I have not, nor anyone else in the company installed anything that would be trying to logon with my account.

You’ll be auto redirected in 1 second. See example of private comment Links: Sophos Support Article ID: 1718, FAQShop Article, Computing.Net Forum Post, McAfee Knowledge Search Search: Google - Bing - Microsoft - Yahoo - EventID.Net Queue (1) Sorry -- Patrik 0 digioz 4 Years Ago That's fine. I hope this helps.

Pete windows-nt-2000-xp This article has been dead for over six months. Click View on the title bar and then click Detail. > Try > to find the program, right click and then Properties. > > I hope it helps you. > > Yes No Additional feedback? 1500 characters remaining Submit Skip this Thank you! By creating an account, you're agreeing to our Terms of Use, Privacy Policy and to receive emails from Spiceworks.

The way I fixed it was: 1. Message Insert Code Snippet Alt+I Code Inline Code Link H1 H2 Preview Submit your Reply Alt+S Ask a Different Microsoft Windows Question Related Articles "Logon Failure: Unknown username or bad password" Under Access Permissions, click Edit Limits to check and, if necessary, change the Access Permissions limits on applications that determine their own permissions. open the errors (one at a time) marked "DCOM" and you'll find the usual message and a long string of letters and numbers. 3.1 This string is relatable directly to a

It was also found on another server that running the Synciwam.vbs file from the inetpub/adminscripts directory resolved this issue.
Click if the comment is good! Windows 2000 > Microsoft Windows 2000 > Home Home Quick Links Search Forums Recent Posts Forums Forums Quick Links Search Forums Recent Posts Articles Articles Quick Go to Start > Programs > Administrative Tools > Component Services 2.

The content you requested has been removed. Use Edit Default for each item to adjust Access Permissions and Launch and Activation Permissions to allow the requested operation to complete. Since even in the detailed list view, you wont be able to see if certain accounts were chosen to operate the services. Unless you want to open the services one by one (: Note that the DCOM and the COM+ directories in Component Services are two different "folders" and list the services differently.

DCOM got error "Logon failure: unknown user name or bad password. " and was unable to logon 'Domain Name\Administrator Name' in order to run the server: {B2B30542-D976-11D3-B188-0040056AC398} windows-nt-2000-xp jackknob 3 posts I have a junction which points to another folder on the same drive as the junction; the problem is the junction is taking up space. To locate your computer, click Component Services, click Computers, and then click My Computer. Join Now hi, i am getting the error with event id 10004 DCOM got error "Logon failure: unknown user name or bad password. " and was unable to logon .\GSH_SMARTMAIL in

See ME312497. What is the role of IIS IWAM account? Hiya Did you get this sorted? Similar Threads Dcom got error event id 10004 Perry Davis, Jul 10, 2003, in forum: Microsoft Windows 2000 Replies: 0 Views: 5,730 Perry Davis Jul 10, 2003 Event Viewer Error ID

Not really nice, but it worked. x 60 Glenn Milne In my case, it was McAfee Groupshield "Junk Folder" credentials causing my issues. Register Privacy Policy Terms and Rules Help Popular Sections Tech Support Forums Articles Archives Connect With Us Twitter Log-in Register Contact Us Forum software by XenForo™ ©2010-2016 XenForo Ltd. What is DCOM?

I am going nuts here, anybody? >> for example - Veritas Backup Remote Agent - local install (asks for >> username/pass for the service; in my case is a special backup We're a friendly computing community, bustling with knowledgeable members to help solve your tech questions. No: The information was not helpful / Partially helpful. Newer Than: Search this thread only Search this forum only Display results as threads Useful Searches Recent Posts More...

The text of the event message may provide details to help you configure the security policy. The way I fixed it was: 1. The customer had created a new policy on the sub level OU containing the DCs to allow another user to logon as batch job. To reset the password for the IUSR_ComputerName account, type the following command (where password is the password that you set in step 5), and then press ENTER:cscript.exe adsutil.vbs set w3svc/anonymoususerpass "password"

x 12 Private comment: Subscribers only. Sage, Aug 27, 2004, in forum: Microsoft Windows 2000 Replies: 3 Views: 1,136 David F. I had the same issue with a MS SQL Great Plains Server. Yes: My problem was resolved.

If the User Account Control dialog box appears, confirm that the action it displays is what you want, and then click Continue. Not a member? Type cd drive:\inetpub\adminscripts, where drive is the drive where Windows is installed, and then press ENTER. 13. This event ID should now stop appearing.

Join the community Back I agree Powerful tools you need, all for free. You may get a better answer to your question by starting a new discussion. I hope it helps you. This error was fixed by running the Synciwam.vbs file as mentioned in the other comments.

Add Cancel × Insert code Language Apache AppleScript Awk BASH Batchfile C C++ C# CSS ERB HTML Java JavaScript Lua ObjectiveC PHP Perl Text Powershell Python R Ruby Sass Scala SQL Error: "Logon failure: the user has not been granted the requested logon type at this computer.", GUID: 3D14228D-FBE1-11D0-995D-00C04FD919C1 - This behavior can occur if the IWAM_MACHINENAME and IUSR_MACHINENAME user accounts do