frigidaire dryer error code e4a Selkirk New York

3 Locations in the Capital District: * 617 Central Ave. Albany, NY 12206 * 2330 Watt St. Schenectady, NY 12304 * 1707 Rte 9 Ste 200A Clifton Park, NY 12065 Call Now For Free Consultation & Diagnostics! What is Computer Answers all about? We are your one stop complete computer and networking solution, with an old fashioned business approach, we don't sell you anything you don't need. Our trained and certified technicians will make your IT related problems or questions history. We take pride in our ability to provide affordable service with a commitment to excellence for all of our commercial & residential clients. So don't settle for geeks or just anyone, count on the guys that have the answers, Computer Answers. Our Goal: Computer Answers is a growing IT firm, with a client focused vision, to create long lasting relationships and ensure mutual growth. Since our inception in 1999 we have strived to provide quality IT products and solutions. Our goal is to be able to provide our customized IT solutions to any business across our great nation; we strive to actualize this by consistently providing outstanding service to all of our clients. Computer Answers Specializes In: * Computer Service * IT Business Management * Network Solutions * Software Services * Cabling & Wiring * Data Recovery * Web Design * Training * Virus Removal Certifications: * MSDN Licensed beta Tester 04 * Microsoft Certified Professional (MCP, Windows 2000)

If you are having any computer related problems or questions call us right now at (518)330-2082. We cater to residential & commercial clients. We resolve the following issues for our clients: Free Diagnostics & Consultation Computer: * Laptop Repairs * Slow * Viruses * Spy Ware * Hardware Repairs * Upgrade Old to New * Corrupted Windows Recovery * Data Restoration Network: * Non-Functioning * Slow * Intermittent or No Connection * Down-Time * Sharing Internet * Fix Data Bottle-Necks * VPN * Remote Access * Firewall Protection and Security Software: * Microsoft Server Configuration * Domain Issues * Access Management * Configure Your Company It Equipment for Your Needs * Point Of Sale Software * QuickBooks Related Networking Issues Server: * Failure * Data Restoration * Upgrades * Configuration & Management * Microsoft Server Configuration * Custom Servers Printer: Fix most printer and other hardware related problems. In-House Free Diagnostics All College Students Take 10% off Any Repairs Bring a Friend for Virus Removal and both receive 20% off. Come visit us at our new location 87 North Lake Ave. Albany NY 12206.

Address 617 Central Ave, Albany, NY 12206
Phone (518) 330-2082
Website Link http://computer-answers.com
Hours

frigidaire dryer error code e4a Selkirk, New York

Thank you. Meaning the drying time has exceeded program time for that cycle. Any other suggestions before I take a $160 shot in the dark? Share it! I believe that the low voltage is the problem and the other 2 codes are the result of the problem.

All rights reserved. © Applianceblog.com 2004 - 2014 Search Fixya Press enter to search. Loading...Oops :Please try again. Go Automotive Baby Care Car Audio & Video Cell Phone Communications Computer Equipment Fitness & Sports Home Audio Household Appliances Kitchen Appliances Laundry Appliances Lawn & It may take two business days for your expert to reply. That is consistent with your description of the details.

If meter reads zero, remove power from dryer. Position cycle selector to NORMAL, temperature selector to HIGH HEAT and touch START. Measure resistance of thermistor. Please try the request again.

Either there is a ventilation restriction or overload. E5B Heater Fault (no heating) Temperature reading of control thermistor has not changed in a certain amount of time. Measure resistance of thermistor. The dryer will run if it is supplied with the 120 volt L1 leg of power (traced in red in the wiring diagram below).

Enter function test mode and perform key (button) test to determine which button is at fault. If this code would appear on a washer in the Non-Digital Readout Display Models, the four indicator lights would blink four times and the START indicator light would blink ten times. The safety (high limit) thermostat has tripped too many times within a certain period of program time. A professional normally ...

ft. You may NOT copy or distribute the content that appears on this site without written permission from Fixya Ltd. © 2005-2015, Fixya, Ltd. I do hope that everything works out on the dryer. Machine is less than a year old.

Search Fixya Press enter to search. If the wiring and the outlet cord are okay, then your next step would be to check the heating element. Irvington, NY "I LOVE seeing customer service excellence, seeing follow through on promises." Gregory R. You can UNPLUG the dryer and check that wiring connection.

If the outlet is okay, then you can UNPLUG the dryer and check the wiring on the terminal block at the back of the dryer. I had so many questions and they answered them all." Sharon S. my new Frigidaire stackable front-loading washer/dryer is shaking violently and moving! Step 2: Please assign your manual to a product: About Advertising About Us Blog Careers News & Media Help Contact FAQ Partners Privacy Policy Terms Community Forums Recent Q&A Top Experts

Remove wires from control thermistor. Check for anything that would extend dry times such as: no heat, restricted vent, blower fan blade broken or loose, dryer installed in closet with solid door, or bad connection in I took the top off and all wire connections seem to be tight. Measure voltage across terminals on relay K2 (heater relay) on electronic control.

Front-Load ... E., Cleveland, TN 37311 1-877-477-7278 AppliancePartsPros.com Customer Service 1-877-477-7278 Email Us Terms of Use Privacy Policy Site Map ©1999 - 2016 AppliancePartsPros.com. by LYLE W. Generated Sun, 16 Oct 2016 02:30:16 GMT by s_ac15 (squid/3.5.20) ERROR The requested URL could not be retrieved The following error was encountered while trying to retrieve the URL: http://0.0.0.10/ Connection

If problem persists, replace electronic control. The other error code E5B may have been E68 which indicates a stuck key. If you send me the model # I can tell you what the part number and price ... If I may be of further assistance as more details become available, please reply to this post. Landell by Manage My Life November 7th, 2011 Comment 0 votes The model is

by Manage My Life March 10th, 2013 Comment 0 votes Your details seem to indicate that you found the tech sheet that is shown in the images below. Model #AEQ6000E (s) 5 answers Related Questions'>Frigidaire AEQ8000FS0 E5b E4A. Check for anything that would extend dry times such as: no heat, restricted vent, blower fan blade broken or loose, dryer installed in closet with solid door, or bad connection in Kansas City, KS "Robin went above and beyond the call to assist me and I was very impressed." Val T.

E25 Control NTC Open Circuit Control thermistor or its wiring is open. S. Position cycle selector to NORMAL, temperature selector to HIGH HEAT and touch START. RepairClinic.com Yes, If you purchase parts from our links here and you install them and it doesn't fix the problem, you have a 365 day full refund when you return them.

Ran diagnostic cycle and get an E4A error code. Press PAUSE CANCEL and SELECT buttons for 6 seconds to exit test modes. Clear code, exit mode and start dryer.