You can achieve this improved initial condition by: Using a previous simulation which has converged at a condition close to the problem simulation's condition. The Journal of Fluids Engineering provides an explanation of predicting discretization errors here: Calculating Discretization Errors. Yes. CFD.NINJA ANSYS 8,236 views 2:55 Ansys Fluent Tutorial (Basic flow simulation through perforated plate) / Grabcad Request - Duration: 19:16.

About Press Copyright Creators Advertise Developers +YouTube Terms Privacy Policy & Safety Send feedback Try something new! Angle | Exp. Multiphase modelling usually requires a higher mesh quality than single phase, and some multiphase models are very strict - for instance accurate surface tension modelling can require aspect ratios of less alpha February 7, 2008, 17:22 Re: ERROR: Floating point exception: Overflow #9 Elisabetta Guest Posts: n/a Hello I did it at the end, thanks to all of

February 7, 2008, 16:55 Re: ERROR: Floating point exception: Overflow #8 alpha Guest Posts: n/a Thank you peter that was helpful. Content is available under GNU Free Documentation License 1.2. Is there any way of doing a 2D simulation in CFX? As Reynolds number increases, grid refinement must, too.

Define the Fluid setup in Ansys CFX-Pre. Create the image/attachment on your local machine e.g. To resolve the issue work through the following points: Read the CFX documentation. If the frame of reference is rotating then it is relative to the rotating frame - so it will be different to the stationary frame by radius x omega.

However, if you instead modeled laminar flow, with the most robust discretization, and changed the boundary conditions to be velocity specified inflows with only one pressure-specified opening, the solution will converge Or have you entered a material property incorrectly? If you find the answer please let me know how you resolved the issue. Is it possible to write back-up files of a FSI simulation in Ansys 11.0?

ICEM CFD includes a quality calculator for a priori grid accuracy. This type of error is caused by physically approximating something to simplify the simulation (e.g., modeling a real fluid as an ideal gas). Lionel Riz 271 views 10:48 How to generate fluid domain - Duration: 4:42. This type of error is usually negligible compared to the others and can be easily decreased by running the simulation in Double Precision mode.

Keep lowering your residual value until the solution no longer converges monotonically. Working... Computer round-off errors are caused when a computer stores floating point data. I get the error "Floating point exception: Overflow".

Jon Forums: CFDEM®coupling- Developer Forum Log in or register to post comments For full access including downloads and forums, please register Username * Password * Create new account Request new password skew_mesh.jpg Click "Go Advanced" Click on "Attachments" (The icon looks like a paperclip) Click "Choose File" and browse to your image (such as skew_mesh.jpg). What kind of coupling methods are possible? Usage errors are caused by user specifications.

My resilduals become flat and i do not observe any change in them for long periods. Floating point exception: Overflow Do you know which could be my mistake? The closer the initial condition is to the real flow field the easier it will be for the solver to converge. How should I ask my question on the CFX forum to get the best possible answer?

Start the CFX Solver Manager and load the .def File. Close Yeah, keep it Undo Close This video is unavailable. Structured boundary layers and other anisotropic regions limit discretization errors. Do a test run with the residuals included in the result file.

Click "Upload" Your image/attachment should now appear in the attachments window. You might need to access this variable using the puzzlingly labelled "..." button. Otherwise, a quiet NaN is returned. :divide-by-zero This exception occurs when a float is divided by zero. You should be back on the Go Advanced editor now.

However, discretization errors also depend on grid quality (e.g., aspect ratio, orthogonality, skew). because there are no tutorials available regarding air and water mixture in ansys help.... Transient simulations are much slower than steady state simulations so be aware that you will need extra patience. Alexander Firsov 1,141 views 0:33 Fluid Analysis in ANSYS - Duration: 8:06.

The time now is 17:36. Sirius CFD 59,766 views 15:00 Ansys 14 Fluid flow FLUENT 1 - Duration: 14:16. Possible solutions might be a better fluid mesh meshsiffness 1/wall distance smaller timesteps These error messages can be difficult to debug as the solver often crashes without leaving a results file Iterative convergence errors are due to the resolution of the RANS equations.

Is a better initial condition required? something might be missing in boundry condition... General Resources Events Event Calendars Specific Organizations Vendor Events Lists Misc Pictures and Movies Fun Links to Links Suggest New Link About this Section Jobs Post Job Ad List All Jobs On CFX - Solver I got this error: ERROR #001100279 has occurred in subroutine ErrAction.

If you want to include swirl in the model use periodic boundaries. Yes. To perform such quick check: -Write out a bc file, by going to FLUENT's Text User Interface (TUI) command line and typing: /file/write-bc/any_name -Use any text editor that has search/replace functionality GRS CAD/CAE 17,042 views 27:47 fluent ansys analysis - Duration: 11:36.

Where are the solid data? 3 ICEM CFD 3.1 Grid Refinement 3.2 Grid Resolution 3.3 Grid Quality 3.4 Where can I find a basic ICEM tutorial? 4 How should I ask maryam CFX 3 May 18, 2010 07:44 Floating point exception: Overflow? You can also make these changes in the bc file. Where are the solid data?

CFDEM®coupling-PREMIUM Online documentation Version History Citing CFDEM®coupling Benchmarks Training Download For everyone: CFDEM®coupling-PUBLIC 4 way unresolved CFD-DEM Resolved CFD-DEM (immersed boundary) Convective Heat Transfer Highly customizable solvers For industry: CFDEM®coupling-PREMIUM Non-spherical Appropriate parameters could be lift, drag, pressure loss, flow rate - what ever is an important parameter to your simulation. However, you have to specify the direction of the backflow at an opening. the result was rounded.