failed to automatically resync pv error 5 Glen Arbor Michigan

Address 2508 Maple City Hwy, Interlochen, MI 49643
Phone (231) 325-4452
Website Link
Hours

failed to automatically resync pv error 5 Glen Arbor, Michigan

First let's look at the SCSI errors: SCSI: Async write error -- dev: b 31 0x022000 This is saying that the device in question is a block device (dev: b 31 Jan 13 03:06:32 hostname vmunix: LVM: Failed to automatically resync PV 1f022000 error: 5 Jan 13 03:14:07 hostname vmunix: LVM: Failed to automatically resync PV 1f022000 error: 5 Jan 13 03:26:57 The PV is not accessible. Jan 13 02:50:22 hostname vmunix: Jan 13 02:50:22 hostname vmunix: LVM: VG 64 0x000000: PVLink 31 0x022000 Recovered.

Solved! Hi,In a HP box (N class) in syslog i can see the following error:Apr 26 08:12:03 lust vmunix: errors from the I/O subsystem. can you do check this disk (c4t2d1)diskinfo /dev/rdsk/c4t2d1pvdisplay -v /dev/dsk/c4t2d1 0 Kudos Reply ANITH PRABHAKAR .C Advisor Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to Update - March 2, 2011 at 09:31: The LVM errors also identify the affected volume group via major and minor number.

Solved! Showing results for  Search instead for  Do you mean  Menu Categories Solutions IT Transformation Internet of Things Topics Big Data Cloud Security Infrastructure Strategy and Technology Products Cloud Integrated Systems Networking vgexport: Volume group "vg170" is still active. /dev/dsk/c15t5d7 /dev/dsk/c15t7d6 /dev/dsk/c15t7d7 /dev/dsk/c15t8d1 /dev/dsk/c16t0d4 /dev/dsk/c16t0d5 /dev/dsk/c16t0d6 /dev/dsk/c19t5d2 /dev/dsk/c19t5d3 /dev/dsk/c23t7d4 /dev/dsk/c24t7d4 /dev/dsk/c24t7d5 /dev/dsk/c24t7d6 # cat vg170.map VGID 075354214cf400f2 1 depot The first 8 characters Filed under Uncategorized About March 27, 2009 My name is Kris, and I'm a sysadmin.

There are two ways to clean this up. Jan 13 02:50:22 hostname vmunix: blkno: 45699128, sectno: 91398256, offset: 3846234112, bcount: 8192. Jan 13 02:50:22 hostname vmunix: blkno: 45699128, sectno: 91398256, offset: 3846234112, bcount: 8192. In this error, 64 (VG 64 0x000000) is the major number for volume groups and 0x000000 (VG 64 0x000000) is the minor number for vg00.

LVM: VG 64 0x000000: PVLink 31 0x021002 Recovered.  このメッセージでは、「SCSI: Read error」となっているのでSCSI接続のHDDでエラーが発生していることが分かります。「Recoverd」という文字もあるので、回復されてるのかと一瞬は思うものの、これが連続して何回も表示されているので、何かトラブルが発生していることが分かります。  ということで、結局アクセスが遅い原因はHDDのエラーにあるらしい、ということがわかりました。ただし、これだけでは本当にそこが原因なのか、確信は持てなかったので、HPに連絡を入れ、サポート担当の方の指示どうりにログを取得して送った所、やはりHDDの故障ということとなり、HDDの交換を行ってトラブルは解決。以後インデックスの作成は大幅に高速化されました。 なぜ解決に時間がかかったのか?  さて、結局「全文検索インデックスの作成が遅い」という問題は、「HDDの故障」という原因によって発生していたことが判明し、「HDDの交換」によって無事問題は解決されました。しかし、実は問題が発生してから原因が判明するまで、2週間ほどかかってしまいました。一方で、HPサポート担当者に連絡を入れてから、こちらにログ取得の指示を出し、原因を的確に判断するまで数時間。こちらから「HDDがおかしいようだ」という情報はあったものの、この問題解決に必要な時間の差はどこにあるのでしょうか。  その答えは、問題解決に必要な「情報収集の手段」や、「情報から原因を判断するポイント」についてを知っているか否か、というところにあります。たとえば、私がシステムログ中にSCSIエラーの文字列を発見したのはまったくの偶然です。一方、サポート担当者の方では「問題が発生したらどこを調べればよいのか」という知識、いうなれば問題解決までの最短ルートを知っていた、ということになります。  ちなみに、HP担当者から指示された作業は以下のとおりです。また、HPが公開しているオンラインドキュメント中にも「性能の評価」という項目で問題発生時にPDの手助けになるような情報が公開されています。 OS情報を表示 # uname -a マシンのモデル番号を表示 # model マシンに接続されているデバイスを表示 # ioscan -fnk カーネルメッセージの表示 # dmesg 接続されているデバイスの情報取得 Showing results for  Search instead for  Do you mean  Menu Categories Solutions IT Transformation Internet of Things Topics Big Data Cloud Security Infrastructure Strategy and Technology Products Cloud Integrated Systems Networking By using this site, you accept the Terms of Use and Rules of Participation. End of content United StatesHewlett Packard Enterprise International CorporateCorporateAccessibilityCareersContact UsCorporate ResponsibilityEventsHewlett Packard LabsInvestor RelationsLeadershipNewsroomSitemapPartnersPartnersFind a PartnerPartner Showing results for  Search instead for  Do you mean  Menu Categories Solutions IT Transformation Internet of Things Topics Big Data Cloud Security Infrastructure Strategy and Technology Products Cloud Integrated Systems Networking

By greping a long directory listing of /dev/dsk for that minor number we find: $ ll /dev/dsk | grep 022000 brw-r----- 1 bin sys 31 0x022000 Feb 9 2003 c2t2d0 The Inside the map file will be the VGID as one, big hex number: Note: The man page vgexport(1M) calls the -s flag the "sharable" option. Have you (or someone else) been working around the back of the mahcine? 0 Kudos Reply Prashanth.D.S Honored Contributor [Founder] Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Corrupt software can be removed with the swremove command, or replaced with the swcopy command.
We can get around this by forcing the patch to be marked as configured and

Seeing the creation date is very similar. # echo "0X4cf400f2=Y" | adb 2010 Nov 29 13:37:22 VGIDs and PVIDs from disk headers The headers of each LVM-controlled disk contain both the I call it the "scanable" flag because all it does is put the VGID line at the top of the map file allowing vgimport to scan all of the PVs in Community System Administration CommunityCategoryBoardUsers turn on suggestions Auto-suggest helps you quickly narrow down your search results by suggesting possible matches as you Without that VGID line in the map file and the "scanable" flag in vgimport, you must specify each PV manually.

Update - March 2, 2011 at 09:31: The LVM errors also identify the affected volume group via major and minor number. Rosetta Stone for Unix Need to know how to scan for new hardware in AIX, but only know how to do it in some other Unix flavor?  The Rosetta Stone for The info is very helpful. Send to Email Address Your Name Your Email Address Cancel Post was not sent - check your email addresses!

The syslog errors above are identifying the device throwing the errors in terms of major and minor numbers. This could be a disk problem, can possibly be corrected by increasing the timeout. First let's look at the SCSI errors: SCSI: Async write error -- dev: b 31 0x022000 This is saying that the device in question is a block device (dev: b 31 Ferguson Acclaimed Contributor [Founder] Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report Inappropriate Content ‎02-02-2010 01:15 PM ‎02-02-2010 01:15 PM Re: vmunix:

Doug's Unix Notes Doug's Unix Notes has a lot of good information and step-by-step guides on older HP 9000 equipment and HP-UX.  Particularly useful are the notes on GSPs, Ignite, and HP Information Technology Resource Center The source for HP-UX, HP 9000, and HP Integrity information.  Need patches, drivers, or firmware?  Need to track your support cases?  The ITRC is for you. I have a failing mirrored system disk., "LVM: Failed to automatically resync PV 1f022000 error: 5" (/dev/dsk/c2t2d0). Amit,Please see this threadhttp://forums1.itrc.hp.com/service/forums/questionanswer.do?threadId=978145Regards,Ninad 0 Kudos Reply Joelmel Roche Valued Contributor [Founder] Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report Inappropriate Content

Filed under HP-UX Committing superseded, but corruptpatches May 30, 2009 Leave a comment In the course of installing HPUX patches, I usually make a point of committing patches that have been Community System Administration CommunityCategoryBoardUsers turn on suggestions Auto-suggest helps you quickly narrow down your search results by suggesting possible matches as you The LVM errors are very similar. and do a vgdisplay -v vgname and check for current pv and open pv.better talk to ur unix admin he might be giving some useful tips to uregardsMC 0 Kudos Reply

HP ITRC Forums The ITRC Forums are a great place to get advice from other IT professionals when you just can't figure something out.  Actually, most of the time I can Skip to ContentSkip to FooterSolutions Transform to a Hybrid Infrastructure Protect Your Digital Enterprise Empower the Data-Driven Organization Enable Workplace Productivity Cloud Security Big Data Mobility Infrastructure Internet of Things Small let me tell the commands to see the errors etc.thanks and regards. 0 Kudos Reply ani007 Super Advisor [Founder] Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Topic Options Subscribe to RSS Feed Mark Topic as New Mark Topic as Read Float this Topic to the Top Bookmark Subscribe Printer Friendly Page Amit Manna_6 Regular Advisor Options Mark

By using this site, you accept the Terms of Use and Rules of Participation. End of content United StatesHewlett Packard Enterprise International CorporateCorporateAccessibilityCareersContact UsCorporate ResponsibilityEventsHewlett Packard LabsInvestor RelationsLeadershipNewsroomSitemapPartnersPartnersFind a PartnerPartner By using this site, you accept the Terms of Use and Rules of Participation. End of content United StatesHewlett Packard Enterprise International CorporateCorporateAccessibilityCareersContact UsCorporate ResponsibilityEventsHewlett Packard LabsInvestor RelationsLeadershipNewsroomSitemapPartnersPartnersFind a PartnerPartner Then:
# extendfs -F {vxfs|hfs} /dev//r
Then you can remount the filesystem. If this is a array, one of the disk for the luns might be problematic,http://support1.itrc.hp.com/service/cki/docDisplay.do?docLocale=en_US&docId=200000048391490Hope this helps.Regds 0 Kudos Reply The opinions expressed above are the personal opinions of the authors,

Obviously, being able to scan for all of the PVs in a VG during importation is nice when a VG can move between multiple machines, but it's just as handy if