eza2590e send error from send_data - edc5140i broken pipe Fayville Massachusetts

With over 30 years of experience, PC Healthstop’s expert technicians service all PC machines. It can be a desktop, a laptop, or even a printer! And the problem can be big or small.

Virus and Spyware Removal Hardware Upgrades Windows and Software Installation Networking Wireless Diagnostics Computer Accesories

Address 255 Worcester Rd, Framingham, MA 01701
Phone (508) 875-4888
Website Link
Hours

eza2590e send error from send_data - edc5140i broken pipe Fayville, Massachusetts

This may require an restart of the AIX FTP server to pick up the new configuration. If you have erroneously received this communication, please notify the sender immediately by phone (704-758-1000) or by e-mail and destroy all copies of this message (electronic, paper, or otherwise). EZA1701I >>> STOR 'USERID.BAT1WORK.D' 125 Storing data set USERID.BAT1WORK.D EZA2590E send error from send_data - EDC5140I Broken pipe. (errno2=0x74520442) EZA2603E Error sending the file 451 Transfer aborted due to file error. function is the C library function that failed and returned an error.

Vander WoudeSr. Mein KontoSucheMapsYouTubePlayNewsGmailDriveKalenderGoogle+ÜbersetzerFotosMehrShoppingDocsBooksBloggerKontakteHangoutsNoch mehr von GoogleAnmeldenAusgeblendete FelderNach Gruppen oder Nachrichten suchen MVSFORUMS.comA Community of and for MVS Professionals FAQ Search Quick Manuals Register Profile Log in to check your private messages Log This means that Windows has closed itsside of the data connection without going through the normal three-wayhandshake. After replying, please erase it from your computer system.

But the errormessage is truly cryptic!EZA1460I Command:EZA1736I PUT 'MVS.DATASET.NAME' WindowsFileName.ftpEZA1701I >>> SITE FIXrecfm 586 LRECL=586 RECFM=FB BLKSIZE=27542500 'SITE FIXrecfm 586 LRECL=586 RECFM=FB BLKSIZE=27542': command notunderstoodEZA1701I >>> PORT 10,171,35,14,6,110200 PORT command successful.EZA1701I The "pipe" on z/OS is "broken", so "fix the z/OS pipe" isthe thought. So, of course, that is what theyzero in on. Doing an ftp from a z/OS batch job to send datato a Microsoft ftp server.

The ftp server runs out of space on thereceiving disk. It looks like it just dropped the connection. Result: old z/OS sysprog gets woken up again.--John McKownSenior Systems ProgrammerUICI Insurance CenterInformation Technology----------------------------------------------------------------------For IBMTCP-L subscribe / signoff / archive access instructions,send email to ***@VM.MARIST.EDU with the message: INFO IBMTCP-L----------------------------------------------------------------------For IBMTCP-L I cannot say that it is a "defect", but itcertainly is confusing.

That was the Netware FTP server, Ibelieve.PeteWe had the identical problem earlier this week with a Unix FTP server,so "broken pipe" is not exclusive to Microsoft."Gray, Larry -Larry A"<***@LowesTo.com> IBMTCP-***@VM.MARIST.EDUSent by: Now I askthem to look at the file share directly (if they havepermission) or totell the Windows SysAdmin to check the file share. Could it be a ssh timeout problem(Note: ssh_tunnel is set false and coz release 220): COZLOG Messages:cozagent ?21:51? I cannot say that it is a "defect", but itcertainly is confusing.

lines.htmlBut in your case, it seems that the network pipes that redirect the stdout and stderr output of your shell script are being disconnected. Reason code 0291 indicates a return code of JRTCPERROR with description, "TCP returned an error identified by the return code," which is the 140 errno from above. I'll admit it is something of a "paper chase". Next by Date: Empty HSM ML1 Previous by thread: FTP - Put Error - EZA2590E Next by thread: RE: FTP - Put Error - EZA2590E Index(es): Date Thread Flag as inappropriate

Waiting for completion... MVSFORUMS.com Forum Index -> Job Control Language(JCL) View previous topic :: View next topic Author Message sivaraj.ramarajBeginnerJoined: 05 Sep 2007Posts: 5Topics: 3 Posted: Tue Jul 15, 2008 12:24 pm Post Change the file size limit to unlimited (fsize = -1) or to a size equal to the size of the file being transferred. I'm very greatful for your help. Álvaro. 2011/7/7 Chicklon, Thomas This seems to work for me: quote site blksize=27998 lrecl=0 recfm=u pri=19950 sec=100 track mode b ebcdic PUT 'My.DSS.DUMP' 'MY.DSS.DUMP'

Cambiar el mainframe por UNIX/Linux/Windows. The batch job gets a bad return code. Top Display posts from previous: All posts1 day7 days2 weeks1 month3 months6 months1 year Sort by AuthorPost timeSubject AscendingDescending Post Reply Print view 4 posts • Page 1 of 1 Return The current operation is ended. Incidentally, the fact that the message ends in the letter "E", rather than the letter "I", indicates that the message describes as *e*rror rather than

Thank you.The Windows server should have returned a message stating disk full orsomething like that. EZA1735I Std Return Code = 27451, Error Code = 00010 EZA1701I >>> QUIT But when I don't specify the FTP command 'QUOTE STRU R', FTP works OK!!! Result: old z/OS sysprog gets woken up again.--John McKownSenior Systems ProgrammerUICI Insurance CenterInformation TechnologyThis message (including any attachments) contains confidentialinformation intended for a specific individual and purpose, and itscontent is protected Programmer Response: Refer to z/OS XL C/C++ Run-Time Library Reference for the function being attempted for the specific reason for failure.

Your assistance in correcting this error is appreciated. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: GET IBM-MAIN INFO Search the archives EPIPE For a connected stream socket the connection to the peer socket has been lost. The "pipe" on z/OS is "broken", so "fix the z/OS pipe" isthe thought. When I got a call from a programmer orproduction support person for this problem, I used to tell them tocontact the SysAdmin for the Windows FTP server who wouldcheck the logand

So, of course, that is what theyzero in on. Submit feedback to IBM Support 1-800-IBM-7378 (USA) Directory of worldwide contacts Contact Privacy Terms of use Accessibility Re: FTP - Put Error - EZA2590E From: [email protected] (Chris Mason) Date: 8 Jul If you receive this e-mail in error, please do not read, copy or disseminate it in any manner. When I got a call from a programmer orproduction support person for this problem, I used to tell them tocontact the SysAdmin for the Windows FTP server who would check the

It could be a network problem, or perhaps the remote processes were terminated for some unknown reason.I assume that there aren't any other messages in the log from the remote side, I cannot say that it is a "defect", but itcertainly is confusing. I have the following errror: EZA2590E send send_data error from - EDC5140I Broken pipe. (errno2=0x74500442) I have seen the manual of messages and appears glosses different for the message As it This tells the mainframe to clean up as best itcan.

It never even occurred to himthat it could be a server problem. I also see that with those FTP servers.I do not know if it can be configured to do anything different, or if the newer IIS levels manage that differently.Peter I. Otra 459 Votos Totales Mirar encuesta... Any review, retransmission, dissemination or other use of, or taking of any action in reliance upon, this information by persons or entities other than the intended recipient is prohibited.

However, this does not assure that data delivery was complete. Hence,zOS says "broken pipe".What the Windows people should have done is be more explicit in their426 reply code. But the errormessage is truly cryptic!EZA1460I Command:EZA1736I PUT 'MVS.DATASET.NAME' WindowsFileName.ftpEZA1701I >>> SITE FIXrecfm 586 LRECL=586 RECFM=FB BLKSIZE=27542500 'SITE FIXrecfm 586 LRECL=586 RECFM=FB BLKSIZE=27542': command notunderstoodEZA1701I >>> PORT 10,171,35,14,6,110200 PORT command successful.EZA1701I Doing an ftp from a z/OS batch job to send datato a Microsoft ftp server.

It is intended only for the addressee(s) named above. Please notify the sender by E-Mail at the address shown. If you are not the sender's intended recipient, you are not authorized to intercept, read, print, retain, copy, forward, or disseminate this message. Um Google Groups Discussions nutzen zu können, aktivieren Sie JavaScript in Ihren Browsereinstellungen und aktualisieren Sie dann diese Seite. .

EZA1617I 31596876 bytes transferred in 13.960 seconds. Back to top Display posts from previous: All Posts1 Day7 Days2 Weeks1 Month3 Months6 Months1 YearOldest FirstNewest First MVSFORUMS.com Forum Index -> Job Control Language(JCL) All times are GMT - EZA1701I >>> STOR 'USERID.BAT1WORK.D' 125 Storing data set USERID.BAT1WORK.D EZA1485I 22342404 bytes transferred - 10 second interval rate 2232.01 KB/sec - O 250 Transfer completed successfully. But the errormessage is truly cryptic!EZA1460I Command:EZA1736I PUT 'MVS.DATASET.NAME' WindowsFileName.ftpEZA1701I >>> SITE FIXrecfm 586 LRECL=586 RECFM=FB BLKSIZE=27542 500'SITE FIXrecfm 586 LRECL=586 RECFM=FB BLKSIZE=27542': command notunderstood EZA1701I >>> PORT 10,171,35,14,6,110 200 PORT

EZA1735I Std Return Code = 27452, Error Code = 00010 Back to top expatIntermediateJoined: 01 Mar 2007Posts: 458Topics: 9Location: Back in Bruxelles Posted: Wed Jul 16, 2008 4:06 am Post subject: Mainframe EngineerThe information transmitted is intended only for the person or entity to which it is addressed and may contain confidential and/or privileged material. I cannot say that it is a "defect", but itcertainly is confusing. File is catalogued.

The ftp server runs out of space on thereceiving disk. If you are not the intended recipient, youshould delete this message and are hereby notified that any disclosure,copying, or distribution of this transmission, or taking any actionbased on it, is strictly