fanuc servo amplifier error codes Hawesville, Kentucky

It sounds like you have a faulty control card on the spindle drive LikeLike Reply Raptor227 says: August 18, 2015 at 2:00 pm Whats its mean when i have a blinking JV1B connected from the L command plug of the axis card, JV2B from the M command plug. Menu Skip to content Home About Us Contact Us PLC Applications Manufacturing News Troubleshooting Search for: Troubleshooting Faults of Fanuc Alpha Servo Drives May 4, 2015Uncategorizedalpha drives, fanuc, fault codes, troubleshootingJoe by 'servo' do u mean the servo motor or the servo drive?

for Fanuc Parts Call:Telephone+1-434-971-1394 (EST)+1-619-477-9011 (PST)Fanuc Parts & CNC PartsFanuc Alpha Module Fanuc Drives Fanuc Control Fanuc Motor Fanuc Monitor Fanuc Power Supply Unit CNC Monitors CNC Manufacturers Newsletter Email address: Generated Sat, 15 Oct 2016 14:50:48 GMT by s_ac15 (squid/3.5.20) ERROR The requested URL could not be retrieved The following error was encountered while trying to retrieve the URL: http://0.0.0.8/ Connection The SPM does not pass the IALM signal to PSM)) QUESTION: Is the SPM is not good ?( no alarm only not ready (-) ) Is there any other reason ? A “9” would occur if the overcurrent was detected using the other drive circuitry in the amplifier and the fault would be caused externally from the drive.

Thanks Darrell LikeLike Reply fanucrepairs says: January 11, 2016 at 4:29 pm Alarm 01 on a PSM is not a fan problem, Please see link below https://fanucrepairs.wordpress.com/category/alpha-power-supply-modules/ You may need a Reply With Quote 05-07-2012,12:59 PM #5 underthetire View Profile View Forum Posts View Gallery Uploads Gold Member Join Date Feb 2009 Location usa Posts 5653 Downloads0 Uploads0 Typical failed capacitor in Alarm code 8 is a L-axis over-current alarm(HCL). I replaced it now it has a alarm code 24 on the driver.

Check you cables are ok and that your control is ok LikeLike Reply Darrell says: January 11, 2016 at 4:24 pm Hello I have an 01 alarm on my fanuc A06B-6077-H111 If you have any questions or need assistance, please call 989-922-0043.  To view our Fanuc Amplifiers in stock and repair capabilities at RepairZone, click here: Fanuc Servo Amplifiers Follow RepairZone About Us Contact Us Exchange Info Repairs Warranty Info Testimonials Need Help? Check all three legs-to-ground because the problem can be in the power plug/terminal box of the motor or the power cables going from the drive to the motor.

LikeLike Reply fanucrepairs says: July 2, 2015 at 8:25 am Hi David Yes you are correct the Spindle Module is most likely causing your fault. Please try the request again. SECOND: With a megger, check each leg-to-ground. Your cache administrator is webmaster.

I am asking if there is anyway I can test the drive in order to determine it is bad other than the 01 alarm. If you still have the HC ALARM, then your drive is probably bad. Generated Sat, 15 Oct 2016 14:50:48 GMT by s_ac15 (squid/3.5.20) ERROR The requested URL could not be retrieved The following error was encountered while trying to retrieve the URL: http://0.0.0.10/ Connection However, we don’t know what caused the drive to fail.

A “9” would occur if the overcurrent was detected using the other drive circuitry in the amplifier and the fault would be caused externally from the drive. Inverter: IPM alarm (M axis) Blinking Inverter: abnormal control power supply A Inverter: DC Link Current alarm (N axis) A. A06B-6079-H106 1 - Check the link (6079 drives only) A 6079 drive can give a fault if the S1 Link is in the wrong position S1 - JV Connections (Type A Remove JV1B and insert into JV2B, JV2B into JV1B.

LikeLike Reply fanucrepairs says: August 19, 2015 at 7:22 am The flashing [-] means spindle is awaiting communication from your control to say everything is ok go ahead and power up. makes sense...would match all your facts and findings.... Another solution we succesfully experimented is to warm up the servo with an hair-dryer for a couple of minutes and then switching it off and on. An incorrect setting will cause an Alarm “8”. 2 – Check the wiring: A L motor is wired in the lower terminals and a M motor is wired in the upper

Please try the request again. Reply With Quote 05-08-2012,07:15 AM #7 mike_Kilroy View Profile View Forum Posts Visit Homepage View Gallery Uploads Gold Member Join Date Sep 2010 Location usa Posts 1566 Downloads0 Uploads0 probably the Get updates delivered to your inbox Enter Email Here*Submit Call Us:989-922-0043 Categories Industrial Electronics Just for Fun! The last drive in the line has a terminator in JX1B. 24v/0v/ESP connected into CX1A from the previous drive, out of CX1B to the next drive in the line. 3 -

Reply With Quote 10-06-2013,08:46 AM #10 terrisinovare View Profile View Forum Posts View Gallery Uploads Registered Join Date Oct 2013 Posts 6 Downloads0 Uploads0 I'm thinking of checking two big caps Remove JV1B and insert into JV2B, JV2B into JV1B. The drive is faulty if alarm occurs, expect a “-” reading. 5 – Release Emergency Stop: Power the machine up after releasing the stop. Reply With Quote 05-08-2012,03:32 AM #6 Robyr View Profile View Forum Posts View Gallery Uploads Registered Join Date Apr 2012 Location italy Posts 3 Downloads0 Uploads0 Originally Posted by underthetire Typical

Related Post navigation Fault Finding on Fanuc Alpha PowerSupplies → 17 thoughts on “Fault Finding On Fanuc Alpha ServoDrives” David says: June 30, 2015 at 1:54 pm ALARM 401 VRDY OFF See the link below if you do not have a megger. All CNCzone.com Content - Copyright © 2014 - All Rights Reserved CNC Machines,CAD/CAD,Milling Machines,Lathes,Classifieds, Lasers,Engraving,woodworking,MetalWorking Our Brands
ERROR The requested URL could not be retrieved The following error was encountered Thank You.

Your cache administrator is webmaster. Hope this will help. All electrical connections appear tight. Please try the request again.

Al. I am right? A A06B-6079 drive can give a fault if the S1 Link is in the wrong position, so check the S1 – JV Connections (Type A Interface) and S2 – JS Connections The leg-to-ground readings should be open, or OL, on all three legs-to-ground.

The machine doesnt even start up either. Main Page Forums New Posts FAQ Calendar Link to us Forum Actions Mark Forums Read Quick Links Today's Posts View Site Leaders Who's Online Downloads Forum Pictures Forum Images Albums Today's If I wait a period lasting from some minutes till an hour (depending on how recently the problem firstly appeared), switching the turning machine off and then on, the error disappears. To do this swap round a – X & Y Motor cables U/V/W/E (at the drive) and b – X & Y Command cables (at the drive) (6096 requires parameters changing

RegardsSimilar Threads:Need Help!- SV003 V abnormal current in servoProblem- Fanuc Alarm 438 - Z AXIS : INV ABNORMAL CURRENT Fanuc servo amplifierProblem- Servo Amplifier FANUC 438 Invertor abnormal current Reply With In this example the drive has detected an overcurrent from the L axis, alarm “8” Swapping the cables over allowed a different amplifier to control the axis. The reading should show infinity (or 500 MEG and above) at the 1000V setting. JX1A connected from previous drive, JX1B connected to the next drive in the line.

Need Fanuc Spares Alarm Code Fault Remedy - Not Ready Drive is Good 0 Control Ready Drive is Good 1 Internal Fan Stopped Replace/Repair Servo Drive 2 Low control power voltage The site is 100% free to join and use, so join today! Retest the machine. A List of Fanuc error codes can be found further down this blog Switch S1 and S2 setting on a Fanuc Alpha Servo Drive.

FIRST: With an ohm meter, check for shorts in the motor by measuring leg-to-leg and leg-to-ground on all three legs.Leg-to-leg readings should be low, but consistent, on all three legs. Fault diagnosis, testing on our rigs, closed loop feedback and a 180 day warranty on repair and exchange! Retest the machine The drive is faulty if the same alarm occurs, ie alarm "8" The fault lies elsewhere on the machine if another alarm occurs, ie alarm “9” In this What else could I check to determine if the drive is bad and in need of repair or replacement?