fatal scsi error at script La Cygne Kansas

Offering fast, friendly, reliable PC repair services to the Garnett area. Quality guaranteed, all services come with a 90 day warranty. House calls welcome, call any time day or night.

Computer repair & services.

Address Garnett, KS 66032
Phone (785) 204-2823
Website Link
Hours

fatal scsi error at script La Cygne, Kansas

And the choice of RAID or JBOD seems to be based on which card in the computer it is connected to, not on which card is plugged into the back of Just click the sign up button to choose a username and then you can ask your own questions on the forum. RE: fatal scsi error at script address 8 illegal instruction fontanez123 (TechnicalUser) 4 Aug 03 09:27 I installed my PCI ultrascsi host adapter on a Sunblade 100 and got no problems Ethernet address 8:0:20:b2:8a:67, Host ID: 80b28a67.

Get a PCI LVD SCSI card for the Netra and you can use all 12 slots with no worry about conflicts. Thanks 0 LVL 1 Overall: Level 1 Message Author Comment by:bkreynolds482008-04-04 yuzh on sunsolve 111292-14 is the last revision of that patch. Also, a HVD SCSI terminator is needed on the other end of the bus in the box. Good Luck, DoN. -- Email: <> | Voice (all times): (703) 938-4564 (too) near Washington D.C. | http://www.d-and-d.com/dnichols/DoN.html --- Black Holes are where God is dividing by zero --- DoN.

You can try the latest version first to see how it goes. 0 LVL 1 Overall: Level 1 Message Author Comment by:bkreynolds482008-04-10 Yuzh as I understand this my OBP version I have to use a HVD SCSI card in my Sun Fire 280R to talk to the D1000. linux dhcp peizhi roc | 关于Unix文件的软链接 | 求教这个命令什么意思,我是新手,刚刚学习 ... | sed -e "/grep/d" 是什么意思?谢谢 ... |  bencyber bencyber 当前离线 富足长乐 富足长乐, 积分 5087, 距离下一级还需 2913 积分 问答 好友 博客 消息 论坛徽章:2 2楼 [报告] 发表于 2007-04-12 17:04 |只看该作者 检查下一OBP的配置,要不把OBP的恢复到出厂设置看行不行。 The switches on the plugins define the range of SCSI IDs assigned to the drives, and if both sides are set the same, you will have conflicts with two drives answering

The readme says NOT to go backward so not sure not how to proceed. Use pwd to print the current working directory: Use ls to list a directory's contents: Use cd to change to a new directory: Use wildcards instead of typing out long directory But have you power cycled the D2 after changing the switch settings? Nichols, Jul 25, 2009 #4 rcswebb Guest Re: Fatal SCSI error at script address 148 Illegal instruction On 25 July, 22:58, "DoN.

Fatal SCSI error at script address 148 Illegal instruction Discussion in 'Sun Hardware' started by rcswebb, Jul 24, 2009. Registration on or use of this site constitutes acceptance of our Privacy Policy. I took your advice and booted the array without just a single disk in position 1. Nichols Guest Re: Fatal SCSI error at script address 148 Illegal instruction On 2009-07-25, rcswebb <> wrote: > On 25 July, 01:01, "DoN.

Thank you in advance. unit IDs don't seem to make sense for SCSI, as you are > limited to 16 SCSI IDs for wide SCSI (which is what you have here). 聽If > it were I've finally found something which tells me that it uses LVD SCSI (not the SE SCSI which is likely what the Netra has), so do you have a LVD controller to This page documents the meanings of both the box and the drive LEDs: and they may be able to give you a hint.

Sun's prtfru command only prints the system board, the CPU modules, and the DIMMs, not anything in the PCI slots. The Sun Blade 1000 and Sun Blade 2000 do have separate busses -- FC-AL for internal plus a lot of external as one bus, an internal SCSI bus for the DVD-ROM You'll be able to ask questions about your motherboard or chat with the community and help others. rcswebb Guest Tried connecting a fully populated D2 storage array to a Netra t105 Results in : ok probe-scsi-all /[email protected],0/[email protected],1/[email protected] Fatal SCSI error at script address 148 Illegal instruction Would anyone

And it looks as though the D2 should be powered on before the computer -- at least for booting from the D2. Join the community of 500,000 technology professionals and ask your questions. If hardware RAID have the drives already been integrated into the array's logic? Changing the value of the unit id rotary switch on the > rear of the d2 unit appears to have no affect on the values resulting > from the probe-scsi-all Hmm

Thanks 0 LVL 40 Overall: Level 40 Unix OS 27 Message Active today Accepted Solution by:omarfarid2008-04-11 The link below show that it is OBP 4.10.1 http://sunsolve.sun.com/search/document.do?assetkey=1-21-111292-14-1 PatchId 111292-14 (OBP 4.10.1) unit IDs don't seem to make sense for SCSI, as you are limited to 16 SCSI IDs for wide SCSI (which is what you have here). Reasons such as off-topic, duplicates, flames, illegal, vulgar, or students posting their homework. If you want to use it as a JBOD, the interface card in the computer should be the 375-3057 -- except that I don't see the Netra t105 in the list

c1t0d0 \r\n /[email protected],600000/SUNW,[email protected]/[email protected],0/[email protected],0\r\n只找到一块硬盘\r\n进入ok状态 probe-scsi-all\r\n\r\n/[email protected],700000/[email protected],1\r\nfatal scsi error at script address 8 illegal instruion\r\n....\r\n/[email protected],700000/[email protected],\r\nfatal scsi error at script address 8 illegal instruion\r\n.....\r\n拔掉光驱,重启错误依旧,系统断电,主板拿掉电池放电,再开机错误还在,还是不能认出第二张盘,可以确认不是硬盘的问题\r\n\r\n\r\n大家帮忙看看这个是怎么回事\r\n急!!!\r\n谢谢! Changing the value of the unit id rotary switch on the > > rear of the d2 unit appears to have no affect on the values resulting > > from the Also, a HVD SCSI terminator is needed on the other end of the bus in the box. Featured Post Maximize Your Threat Intelligence Reporting Promoted by Recorded Future Reporting is one of the most important and least talked about aspects of a world-class threat intelligence program.

I get the error when I place a disk in position 0 within the array, which obviously conflicts with the internal disk. Newer Than: Search this thread only Search this forum only Display results as threads Useful Searches Recent Posts More... Nichols" <> wrote: > >> On 2009-07-24, rcswebb <> wrote: > > >> > Tried connecting a fully populated D2 storage array to a Netra t105 > > >> > Results Which one is better for starting?

Is the D2 a JBOD like the D1000, or is it a hardware RAID system? Connect with top rated Experts 12 Experts available now in Live! Yes, my password is: Forgot your password? O.K.

I have searched the internet with not much luck. Click Here to join Tek-Tips and talk with other members! Please turn JavaScript back on and reload this page. And the choice of RAID or JBOD seems to be based on which card in the computer it is connected to, not on which card is plugged into the back of

So please if you have any idea HELP ME. I have used this procedure on the Solaris 8 and 9 OS, and it shoudl also work well on the Solaris 10 rel鈥 Unix OS Linux/ Unix Bash Shell: Navigating the If they are not integrated, or if the box is a JBOD, I would start by pulling out all drives, and see what information you get. Cancel Red Flag SubmittedThank you for helping keep Tek-Tips Forums free from inappropriate posts.The Tek-Tips staff will check this out and take appropriate action.

ok probe-scsi-all /[email protected],0/[email protected],1/[email protected] Target 0 Unit 0 Disk SEAGATE ST318404LSUN18G 4207 Target 1 Unit 0 Disk FUJITSU MAP3367N SUN36G 0401 Target f Unit 0 Processor SUN D2 3034 My knowledge of [email protected] Please see http://www.freebsd.org/doc/en_US.ISO8859-1/articles/freebsd-update-server/ for the updated article. dEVRim-

vvv Home | News | Sitemap | FAQ | advertise | OSDir is an Inevitable website. If this is normal behaviour, how would > I alter my setup so that I could use both the internal disk (the > segate) and all 12 slots within the d2.

what happen if you try "reset-all" at OBP prompt? Have you looked at the LEDs on the D2? I tried to reset the scsi connection but that didnt help. Privacy Policy Site Map Support Terms of Use [prev in list] [next in list] [prev in thread] [next in thread] List: sun-managers Subject: Fatal SCSI error at script address 8 Illegal

If you have any questions, please feel free to mail me. Login with LinkedIN Or Log In Locally Email or Username Password Remember Me Forgot Password?Register ENGINEERING.com Eng-Tips Forums Tek-Tips Forums Search Posts Find A Forum Thread Number Find An Expert You can not post a blank message. Join Us! *Tek-Tips's functionality depends on members receiving e-mail.

so the D2 shows up as a device on its own -- perhaps for > asking about the status of disks installed. 聽IIRC, this was a 12-slot > unit, so target Nichols Guest On 2009-07-24, rcswebb <> wrote: > Tried connecting a fully populated D2 storage array to a Netra t105 > > Results in : > > ok probe-scsi-all > /[email protected],0/[email protected],1/[email protected] rcswebb, Jul 25, 2009 #3 DoN. But it would appear that your Netra does not have a separate SCSI bus for the exterior.