Company Vision Efficient voice and data communication systems start with a clear understanding of the current needs and future goals. CTA's sales and design staff work with customers to determine those needs and goals, matching them with the proper equipment. Based in Wichita, Kansas, CTA provides service to businesses nationwide. Integrating voice and data communication on a national level improves efficiency, reduces cost and is a particular area of expertise within CTA. Today's businesses require wide area networking design and equipment, telecommunication solutions and the technical knowledge to put it all together, seamlessly...

Design and Implementation *Custom Network Design, Setup, & Configuration *Remote Administration, Trouble Shooting of Voice & Data Networks *Fiber Optic *Cat5E PVC & Plenum *Cat3 PVC & Plenum *Patch Panels *Cabinets / Data Racks *Custom Made Cables *Voice & Data Networks *AT&T Solutions Provider Computers and Data Equipment *Computers *Services *WAN / LAN *PBX *Switches / Hubs *Routers *VoIP *Computer Networking *Custom PLEXAR *Phone Systems / Voicemail Systems *UPS Battery Backups Wire Runs *Patch Cables *Voice Runs *Data Runs *Set Up *Network Monitoring *Coaxial Cable Network Security & Monitoring *System Monitoring *Content Filtering Devices *Virus Protection and Monitoring *24 Hour / 7 Day a Week Support

Address 2007 S Hydraulic St, Wichita, KS 67211
Phone (316) 267-5016
Website Link http://www.cta-inc.com
Hours

fatal scsi error at script address 8 illegal instruction La Cygne, Kansas

O.K. Some SCSI devices require a system Extension to properly access or mount the SCSI device. If it is clean, add one drive at a time and repeat the test seeing if any particular drive brings up the error. Top This thread has been closed due to inactivity.

Mattar zmattar at atc.com.sa Thu Mar 28 01:37:54 CST 2002 Previous message: [SunHELP] convert sendmail.cf Next message: [SunHELP] Content checking for Intrusion Detection Messages sorted by: [ date ] [ thread Map of current Puerto Rico Surface Water Temperatures based on measurements from oceanographic satellites Map of current Puerto Rico Sea Water and has been hosting the best surfers in the industry Resources Join | Indeed Jobs | Advertise Copyright © 1998-2016 ENGINEERING.com, Inc. Terminators have resistors placed at either end of the SCSI chain to supress noise.

what happen if you try "reset-all" at OBP prompt? Solution 6 A SCSI device may be damaged (e.g., loose cable connectors, improper or damaged terminators, excessive SCSI cabling). Many SCSI devices have internal active or "powered" termination that can substitute for the second terminator. If it is dying under probe-scsi-all, then it sounds like low level hardware problems.

Using Virtualization to Balance Work with TCO Evolution of End User Computing--Evolving to Better Meet ... Good Luck, DoN. -- Email: <> | Voice (all times): (703) 938-4564 (too) near Washington D.C. | http://www.d-and-d.com/dnichols/DoN.html --- Black Holes are where God is dividing by zero --- DoN. Thx and regards. Click Here to join Tek-Tips and talk with other members!

Unknown User replied Jan 30, 2003 Hello, You can have a look on the following link for the troubleshooting of daisy chain . Previous message: [SunHELP] convert sendmail.cf Next message: [SunHELP] Content checking for Intrusion Detection Messages sorted by: [ date ] [ thread ] [ subject ] [ author ] More information about Fatal SCSI error at script address 148 Illegal instruction Discussion in 'Sun Hardware' started by rcswebb, Jul 24, 2009. Check the SCSI address on the device (usually on the back of the device next to the SCSI port).

This way you will get a faster, better response from the members on Motherboard Point. The data sheet at http://www.sun.com/storage/tape/l180/l180_datashee t.pdf said you need SCSI Wide, high-voltage differential. Annihilannic. Unknown User replied Jan 29, 2003 How are the SCSI IDs set?

Close Reply To This Thread Posting in the Tek-Tips forums is a member-only feature. unit IDs don't seem to make sense for SCSI, as you are limited to 16 SCSI IDs for wide SCSI (which is what you have here). If not is it possible to try the SCSI chain on a different box. Nichols, Jul 25, 2009 #4 rcswebb Guest Re: Fatal SCSI error at script address 148 Illegal instruction On 25 July, 22:58, "DoN.

Check for a conflict between each combination of the SCSI devices. All rights reserved.Unauthorized reproduction or linking forbidden without expressed written permission. I have located the problematic one, is there any way I can get the contents from the bad one or can I get it repaired by some other means? The switches on the plugins define the range of SCSI IDs assigned to the drives, and if both sides are set the same, you will have conflicts with two drives answering

You can try the latest version first to see how it goes. 0 LVL 1 Overall: Level 1 Message Author Comment by:bkreynolds482008-04-10 Yuzh as I understand this my OBP version jayasimha.shatrughna replied Jan 29, 2003 Hi I changed the SCSI ID to 11 and hard booted both the E250 as well L180 Tape Library But {0} ok probe-scsi-all /[email protected],4000/[email protected],1 /[email protected],4000/[email protected] Fatal This seemed to recognise the > > single disk and controller: > > > Netra t1 (UltraSPARC-IIi 440MHz), No Keyboard > > OpenBoot 3.10.24 ME, 256 MB memory installed, Serial #11700839. Termination is very well taken care I changed the scsi cable but that also didnot help I am sure that the connections are really fine .

Reasons such as off-topic, duplicates, flames, illegal, vulgar, or students posting their homework. Till the 4th Drive it would recognize all the drives Can somebody help me ,I have a dead line for this :( When I connected the 5th drive i am getting Talk With Other Members Be Notified Of ResponsesTo Your Posts Keyword Search One-Click Access To YourFavorite Forums Automated SignaturesOn Your Posts Best Of All, It's Free! SCSI terminators are plugs that fit into SCSI ports.

Home | Invite Peers | More UNIX Groups Your account is ready. Join your peers on the Internet's largest technical computer professional community.It's easy to join and it's free. Powered terminators usually have lights to indicate the status of the connection. Red Flag This Post Please let us know here why this post is inappropriate.

Always start with the minimum configuration for a test. Solution 2 Remove termination. https://spe.sun.com/info/control/DocumentSelectByType/doc=566/816-2578/pdf > I get the error when I place a disk in > position 0 within the array, which obviously conflicts with the > internal disk. wipro !

Regards, Richard Webb rcswebb, Jul 24, 2009 #1 Advertisements DoN. when i change to the OK prompt where i run a probe-scsi-all.when i do this i get a fatal scsi error at script address 8 illegal instruction error so i have This seemed to recognise the > single disk and controller: > > Netra t1 (UltraSPARC-IIi 440MHz), No Keyboard > OpenBoot 3.10.24 ME, 256 MB memory installed, Serial #11700839. > Ethernet address Cheers --Jays 4 Tape Drives connected thru daisy chain {0} ok probe-scsi-all /[email protected],4000/[email protected],1 /[email protected],4000/[email protected] Target 0 Unit 0 Removable Device type 8 STK L180 0200 Target 1 Unit 0 Removable Tape

saclarkdoc posted Jul 16, 2016 ARM7 LPC2138 Thiago Brandão posted Jul 5, 2016 PCI9080 DEHGHAN posted Jul 4, 2016 Firmware update's X2200 M2 ylm1994 posted May 1, 2016 Manual for ZT8817 I 'm getting the following error message when I have tried to boot the Sun Fire V420R having 2 disks. O.K. Sign up now!

chukcha2 posted Sep 24, 2016 ASUS A88XM-A on-board video issue GalacticDad posted Sep 15, 2016 three screen setup with the gtx 650 hassan123 posted Sep 2, 2016 Dark spot/residue on... It never mattered to me, because I had to connect the D1000 to a separate controller card anyway because it needed HVD, not LVD (which usually will work as SE SCSI, The Ultra-60, however, was the first which I had to have external SCSI bus separate from the internal. > My knowledge of SCSI is limited to say the least, but I SCSI ID number 0 is reserved for the internal hard drive, SCSI ID number 7 is reserved for the Macintosh itself. 4.

I believe that they are read only at power-up, so a change while it is still powered up would not show up in the behavior until the next power cycle. In split bus mode, both halves run SCSI IDs There is a manual for it -- but I apparently don't have the permissions to download it.