gecko spa flo error West Suffield Connecticut

Address 68 Cleveland St, Springfield, MA 01104
Phone (413) 391-7636
Website Link
Hours

gecko spa flo error West Suffield, Connecticut

Or you can just order a new pressure switch (probably about $30-$50) and swap it out to see if that works. The system returned: (111) Connection refused The remote host or network may be down. Check water level in spa. Hold = Panel sensors have been pressed too many times in a short period of time.HOT = Circuit Board temperature has exceeded acceptable limit.ICE = Freeze protection.

Once I hooked the topside control panel back in, nothing displayed in the red led screen. Heater is deactivated.FL1 = Water flow problem, inhibited or pressure switch malfunction. another important thing to check is the air lock... If display shows only this message (blinking) spa is shut down.

If not, the video will give you some good pointers. After many uses, the temperature seems to go down one day, then went back into normal, 105°.The hot tub ran every 4 hours and after the cooling issue, it would only If pump 1 was turned on due to this reason alone, this message will appear for up to two minutes right after very cold water is detected. No action is necessary.PnL = Communication between the panel and circuit board is faulty.---- = "Watchdog" (spa is deactivated) A problem has been detected.Sn1 = Open sensor (heater is deactivated) or

Give me a short while and I'll check my other manuals. If you need further help with troubleshooting click here Balboa Spa Side Error Codes pd = Power supply, unit running on battery backup OH = Sensors reading 112-118° F. I replaced the temp sensors but still get the error. But if that's all working properly, then the next step is that we want to look at the pressure switch.

If the water gets too low and the spa's filter well is not completely submerged it can cause air to be drawn into the system giving you a low flow error.How I am not near a repair place, but can have one come in…it may take a few weeks… admin September 14, 2015 at 2:18 pm You have checked all the easy I have changed circ pumps. You see if the flow is not at the desired level there is usually a good amount of air in the lines, when a spa heater or motor is running with

its not the filter or air in lines Logged keat63 Full Member Posts: 218 Re: flo error - gecko artic spa « Reply #3 on: September 04, 2013, 04:17:23 AM » Contact ACC. For now if you have tried pulling the filters and your water level is fine my advice would be to call an experienced technician to troubleshoot the issue. So if the pump is weak that is your culprit.-Jay Tim December 29, 2015 at 7:19 pm Like the rest of you I have a problem.

Last week FLO code. Spa has shut down. All of a sudden it began to to work again (going through cycles). as for it being in backwards the heater is always on the pressure side of the pump when it comes to gecko packs.

It started with the heat element then I replaced it but the circuit board brunt up because I left it running in the rain. LF = Persistent low flow problems. (Displays on the 5th occurrence of "HFL" message with 24 hours). Sn1 = Open sensor (heater is deactivated) or Shorted sensor (spa is deactivated). admin June 7, 2016 at 8:53 am Hi Phil,If you hear the relay kicking but the pump is not engaging the motor could be shot.

Generated Mon, 17 Oct 2016 05:01:06 GMT by s_wx1131 (squid/3.5.20) HomeTestimonialsBlogIndustry LinksPolicies, Warranties and DisclaimersService Area-Contact UsSpas / Hot Tubs & Swim SpasFilter Cartidge Cleaning - Home remedySterilizing before UsageProperly Closing-WinterizingError I made a weak connection that must have added a little resistance the the FLO went away. Loading... I have you guys bookmarked now for all my hot tub needs and will be referring others to ur site because of ur prompt service and very reasonable prices." - Sarah

SL = Sleep mode Brett Aqualine Control Systems for Spas or Hot Tubs: OH = Temp exceeds 118° F Fr = Freeze condition - temp below 40° FFL = Pressure switch Hot tub low flow error causes and solutions……. The first thing and most important thing to try is to restart your Arctic Spa by turning the breaker off and on again. you have to be 100 % sure that you see water coming through your jets when your low speed pump is on .

Ecn = Spa operating in Economy Mode. You are here:HomeThe Pool BlogHot tub low flow error causes and solutions……. Sign in 10 Loading... I believe I have two problems anyway.

COOL = Spa water is more than 20° F cooler than the temperature set point. dr = Inadequate water detected in heater. F2 = 4 hours daily filtration F4 = 8 hours daily filtration F6 = 12 hours daily filtration FC = continuous filtration Sundance Spa Side Error Codes ILOC : Interlock failure Switch closed while pump is deactivated.

The first thing to do is shut the spa down, remove the filter and make sure all the jets are open. Sign in to report inappropriate content. Any idea? Sensor plugged into jack A is not working.Snb = Spa is shut down.