Unfortunately all three parameters are inter-related so that by adjusting one parameter will effect any of a previous parameter adjustments. Step 1: Fig. 2a shows the result of slowly increasing only the proportional term. However, older drives may need new firmware loaded. Also, when commanding moves using the 1-D Interactive or 2-D Interactive screens in MAX, navigate to the Advanced tab at the bottom of the screen.

The transformer is driven with a sinewave reference signal. control. How do I load a .ccx file? As an example of this tuning approach, we investigate the response of a Compumotor Gemini series servo drive and built in controller using the same motor from the previous example.

Excite the system with a step command. Many of the DC powered drives have an AUX HV that can also be used with a +24Vdc keep alive but it not required for operation. A basic servo controller generally contains both a trajectory generator and a P.I.D. Tuning the P.I.D.

See the “flash” example. and P.I.V. The simplest type of feedback is called proportional control.Other types are called derivative and integral control. These parameter settings compensate for the difference between the actual motion and the commanded motion - getting the actual as close to the commanded as possible, with minimal oscillation and noise.

When operating a stepper system, some additional methods that can change resonance vibration frequencies are: Half stepping or microstepping the motorChanging the system inertiaAccelerating through the resonance speed rangesModifying drivetrain torsional The UL online certifications d ictionary will contain the links to the relevant files for the Copley drive product. CML requires a license agreement and payment of a nominal fee. Go to the UL website, click on certification then enter “Copley Controls” as the company name and the first three letter of the model number as the Keyword.

a) Position Response b) Velocity Response Figure 7. An In-Position signal is often used to make sure the motor stops before the machinery continues its operation. Encoders Encoders direct pulses of light, from a light source at the motor or load, to photo detectors through an encoded disk. Step 1: Set Ki and Kd to zero.

In Position When a motion command stops executing, and the motor slows to within a few counts of its target position, the motor is considered to be stopped, or "In Position." Why do I get SDO timeout using CMO? Overall drive efficiency depends on the operating conditions of voltage and current. Complete servo control systems combine both these types of servo control to provide the best overall performance.

Their procedure basically boils down to these two steps. For example, every motion control system has hardware limit switches, which are used in the position loop to set a limit on how far the actual motor position can deviate from The familiar "P.I.D." (Proportional Integral and Derivative position loop) and "P.I.V." (Proportional position loop Integral and proportional Velocity loop) controls are used to combat these types of problems. With a quadrature encoder, this results in four edges (rising and falling on lines A and B) for every quadrature pulse of the encoder.

Every motor has at least two magnetic motor poles, normally four or six. Low-resolution encoders contribute to poor velocity estimations that lead to either limit cycling or velocity ripple problems. The most common cause of this error message however is poor cabling so verify proper cabling. In contrast, the trial and error settings gives a quicker settling time, however no solution was found to completely remove the overshoot.

This assumption allows us to model the total system inertia as the sum of the motor and load inertia for the frequencies we can control. Most piezoelectric systems and inexpensive micrometer-replacement actuators are open-loop devices.Open-loop positioners are useful when remote control is desired for improved accessibility or to avoid disturbing critical components by touching them.Stepper and Answered Your Question? 1 2 3 4 5 Document needs work? Actually there are several faults that are not latching by default.

The most common cause of following error is caused by a current limiting. In this mode a simple string is sent to node 0 and passed to the proper node and then a response is sent back. Solution: What is following error?NI 73xx motion controllers contain an on-board PID control loop that allows them to use position and velocity feedback to adjust their command signal. See the CME 2 Indexer User Guide.

Disturbance rejection plots for the P.I.V. HOME LOGIN SUBSCRIBE InTech News Products Job Center Directories Events Library InTech News Featured Product Industry Project Event Training By Company e-Newsletter Archives Products Featured Products Product Search Job Center Search When using high peak and continues currents in a profile move be sure to check the rms of the typically profile and dwell time. Case No. 4 bad Halls.

Closed Loop Servo Systems In a servo system, feedback information - motor position and motor velocity is sent from the feedback unit of the motor back to the servo amplifier. Check with drive disabled and then again enabled commanding 0A. My Profile | RSS | Privacy | Legal | Contact NI © 2014 National Instruments Corporation. I/O can be used in conjunction with the CVM Indexer to home and make sequential moves by setting PLC outputs to select a sequence and initiating a GO line.

P.I.V. When using a network the drive must first be hardware enabled and then the master must transition the state machine from pre-operational to operational mode before software enabling over the network. This is why users occasionally request "high inertia" motors even at the expense of requiring more overall torque to make their move. Please Contact NI for all product and support inquiries.

Case No. 1: cabling, grounding, and shielding. You may also program software limits via DRIVE.EXE parameters. The .ccx file can also be loaded over the CANopen or EtherCAT network from the Copley CMO or CML software using the LoadFromFile method. Open-Loop Control Open-loop refers to a control technique that does not measure and act upon the output of the system.

Can I use 64-bit Windows? velocity loop. This feedback, read from either analog voltage or pulse-train encoder signals, indicates the actual position/velocity of the motor.