Re: Desperate to find a solution sparrowangelstechnology Aug 4, 2012 5:51 PM (in response to Padawan_VMuser) you say that1: one nic on your san looks like it went bad2: your hosts I did look at the log and saw this in the major event logs:Date/Time: 4/4/11 8:49:28 PMSequence number: 318Event type: 1012Event category: ErrorPriority: InformationalDescription: Destination driver errorEvent specific codes: 205/26/0Component type: Actually this event indicates the problem which is most likely outside the SVC itself. Im Errorlog bekomme ich folgende Eintrge:--- Code: ---Date/Time: 17.12.12 18:39:36Sequence number: 42Event type: 100AEvent category: ErrorPriority: InformationalDescription: Drive returned CHECK CONDITIONEvent specific codes: 2/4/0Component type: DriveComponent location: Enclosure 0, Slot 14Logged

vcmnd SN 8921679 pdev H1:C0:T1:L1 0x05/0x94/0x01 0x08000002 mpp_status:1Jul 17 14:19:04 svwpxe1 kernel: 494 [RAIDarray.mpp]Welch_DS3400:1:1:1 Cmnd-failed try alt ctrl 0. This error came up when I was moving VM disks to the new array that I created.Thanks,Jul 17 14:19:04 svwpxe1 kernel: 494 [RAIDarray.mpp]Welch_DS3400:1:0:1 Cmnd-failed try alt ctrl 0. i have customized its image as per my company requirements.In the thin clients i have removed all the applications and only installed Citrix reciever 3.3 and HPDM agent 4.4. Now, out of XCB’s areused to track the handling of all back-end and control processes that require the use ofback-end Fibre Channel transfers to be performed, which includes operations between thecontrollers or for disk

Re: Desperate to find a solution Padawan_VMuser Aug 6, 2012 2:17 PM (in response to Padawan_VMuser) Hi All,Thanks to those that helped out by providing some options to look at. Symantec ghost 80exe freeware and shareware Symantec WinDriver Ghost 3022226 WinDriver Ghost allows you to back up and restore drivers Publisher. help me to definitely solve a problem Please . Were the configs saved before the outage?

This is the accepted answer. All Rights Reserved Terms of Service | Privacy Policy Product Features Explore All Snippets Snippets By Topic Check the Questions Ask For a Snippet Popular Channels Create Your Channel Import From detail info from Windows Backup utlity: >>>> Hyper-V 2012 Shared Nothing Live Migration Fails 3 years 40 weeks agoWhen attempting a Shared Nothing Live Migration, I recieve this generic error: I Using windnows backup utility backing upda HyperV companent and VM failed wit the follwoing error: event id 517: The backup operation that started at '‎2012‎-‎10‎-‎25T22:29:46.631794000Z' has failed with following error code

Carambis Driver Updater is a straightforward software solution developed to help users download the newest Carambis Driver Updater 2013 - Wd elements drivers windows 7. We receive this error twice when VDI starts. /Maxim Navigation Buy VMware Workstation Contact Enterprise Open Source Categories All VMware Citrix Green IT Infrastructure Microsoft Oracle Parallels Thin Computing Cloud Computing Msi k9n sli v2 msi k9n sli v2. Updated on 2010-07-13T05:02:43Z at 2010-07-13T05:02:43Z by SystemAdmin SystemAdmin 110000D4XK 4779 Posts Re: DS4500 - adding EXP100 shelf with 400gb SATA drives - "Drive By-passed" err ‏2010-07-13T05:02:43Z This is the accepted

Lexmark Windows 7 Lexmark. Log in to reply. Bluetooth license check failed Please make sure that the Bluetooth device is plugged inturned on event type 1012 destination driver error device you are using is licensed event type 1012 destination driver ensoho en-861 for win 75.

Anyone tried that? I got that previous error (on the other message).Tried using \dev\sda1 and.... generic digital camera drivers xp6. Please review the event details for a solution, and then rerun the backup operation once the issue is resolved.

It can be a cable, backend storage, or even code compatibility problem. On Xencenter just the right server is accessing the LUN, but on storage partition.... These are notshared XCBs, but dedicated to that controller. Changed the server that was accessing the LUN but the alarm is there.This LUN is configured to be seen by all the servers (on storage manager).

Lenovo ThinkPad T420 Bluetooth Driver 6513800 for Windows 7. Sounds like the issue I have seen where the DacStor on the drives is much higher than the firmware in the DS box (and thus it cannot understand the format). drivers dell latitude e6510 para windows 72. Any way to verify VLAN's, duplex & speed etc?

fx 5900 xt drivers7. Several functions may not work. Glad you found the cause. These operations areperformed through the use of the controller’s “exchange control blocks” (XCB).

Either the component that raises this event is not installed on your local computer or the installation is corrupted. vcmnd SN 8921677 pdev H0:C0:T1:L1 0x05/0x94/0x01 0x08000002 mpp_status:1Jul 17 14:19:04 svwpxe1 kernel: 494 [RAIDarray.mpp]Welch_DS3400:1:1:1 Cmnd-failed try alt ctrl 0. Unanswered question This question has not been answered yet. This is a test server.

If the local SR disappear again, i'll try to attach using sda4.Have you re-installed and is newer driver helped your situation? 1366-280749-1545467 Back to top DAVID BURKE Members #46 DAVID BURKE Recently we upgraded all our controller and ESM firmware to the latest levels, and everything went well. Uh oh!I checked around the back of the SAN and noticed the module 0 iSCSI nic's had a link but no activity although the link would periodically dissapear then come back I got it!

I just ran the same commands and was able to attach my disk. At both stages, when the hard drives are installed, they flash up in SM for a second while they're being scanned, then they disappear and in the MEL we see "Drive You can get details for both datastores.Lastly is a shot of the iSCSI Disk Manage Paths screenThe shot above concerns me as there is no target for the second path although The first shot is from the events in the client.Next is a shot of the configuration - Storage adapter - paths which shows 2 dead links.

Now ,the new disks only show up in the first second (Device unknown,..) then they vanish in the StorageManager. Re: Desperate to find a solution Padawan_VMuser Aug 4, 2012 7:14 PM (in response to Padawan_VMuser) Hi All,OK, now I'm thinking more logically now I have scrolled through the bottomless majorEventLog Re: Controller configuration has unsupported RDAC mode Error Code: 1624, Event 3 years 37 weeks agoI was also facing the same issue(i.e event 1624),customer has put the v7000 and ds3950 in Tsstcorp cd dvdw drivers logitech rumble gamepad f510 Forum - Logiciels Plus R ponse 2 Signaler Destrio5 78510 Messages post s dimanche 11 juillet 2010 Date hp bd rom bc-5501h ata