ezasoket error Falkville Alabama

Address 1650 County Road 1145, Vinemont, AL 35179
Phone (256) 739-0386
Website Link http://www.guthriecomputer.com
Hours

ezasoket error Falkville, Alabama

I'm asking for my client 6. Ask Question Free Guide: Managing storage for virtual environments Complete a brief survey to get a complimentary 70-page whitepaper featuring the best methods and solutions for your virtual environment, as well The select/selectex would never complete. NO_RECOVERYFatal error occurred.

Prior to doing the CONNECT call you must issue a SOCKET call to get a socket number assigned to your task. Retry the task. 2003 ESUBTASKINVALID REXX The subtask ID is incorrect. In the client program I need move some value to SOCKID?? 0 pointsBadges: report RogerRabbit Sep 18, 2006 1:33 PM GMT CICS Version TS 2.3 Z/OS Verison 1.4 I've been Correct the parameter list passed to the REXX socket call. 2002 ECONSOLEINTERRUPT REXX A console interrupt occurred.

Request TTLS_RESET_SESSION and TTLS_RESET_CIPHER only when TTLS_INIT_ CONNECTION has been previously requested for the connection. 1 EPERM IOCTL (SIOCTTLSCTL) Denotes one of the following error conditions: The TTLS_INIT_ CONNECTION option was Verify TCP/IP is active. 1016 EIBMTCPABEND All An abend occurred when TCP/IP was processing this request. Correct the command parameter. Or what it means?BSI TCP stack.Thanks.Daniel GoftonCounty of Saginaw, Michigan(989) 790-5525In three words I can sum up everything I've learned about life: It goes on- Robert Frost Steve 2004-05-27 17:46:21 UTC

Sort by: OldestNewest Sorting replies... Regards, Scott P.S. Call your system administrator. 55 ENOBUFS IP_BLOCK_SOURCE, IP_ADD_SOURCE_ MEMBERSHIP, MCAST_BLOCK_SOURCE, MCAST_JOIN_SOURCE_ GROUP, SIOCSIPMSFILTER, SIOCSMSFILTER, setipv4sourcefilter, setsourcefilter A maximum of 64 source filters can be specified per multicast address, interface address pair. Reduce the number of links to the accessed file. 32 EPIPE All The connection is broken.

Check the validity of function parameters. 9 EBADF Select One of the specified descriptor sets is an incorrect socket descriptor. Call your system administrator. 75 ENOMSG All There is no message of the desired type. Check the validity of function parameters. 13 EACCES All Permission denied, caller not authorized. Otherwise, call your system administrator. 3 ESRCH All The process was not found.

Please try the request again. Correct the protocol family. 47 EAFNOSUPPORT Bind Connect Socket The specified address family is not supported by this protocol family. Modify the policy to enable AT-TLS for the connection. 45 EOPNOTSUPP RECV, RECVFROM, RECVMSG, SEND, SENDTO, SENDMSG The specified flags are not supported on this socket type or protocol. Error number Message name Socket type Error description Programmer's response 1 EAI_NONAME GETADDRINFO GETNAMEINFO NODE or HOST cannot be found.

RogerRabbit. Correct the SOCTYPE. 10 ECHILD All There are no children. Call your system administrator. 78 EDEADLK Select Selectex None of the sockets in the socket descriptor sets are either AF_INET or AF_IUCV sockets and there is no timeout value or no Verify that z/OS Communications Server installation was successful and that message files were properly loaded. 77 EIDRM All The identifier has been removed.

From: J R Sent: ‎Friday‎, ‎March‎ ‎21‎, ‎2014 ‎11‎:‎15‎ ‎AM To: IBM Mainframe Discussion List The ones at the back are the ERRNO descriptions, which don't apply to GETHOSTBYNAME. One thought that comes to mind is that you may not have specified a valid socket number on the CONNECT call via the S parm. Set on Select() or Selectex(). 113 EBADF Takesocket The socket has already been taken. Decrease the number of processes or increase the process limit. 68 EUSERS All There are too many users on the system.

TCV 0 LVL 26 Overall: Level 26 Mainframe Languages 5 TCP/IP 1 Message Active today Expert Comment by:tliotta2008-09-03 TCV: First "obvious" possibility would be a simple telnet to the same Check policy and add ApplicationControlled On if the application should be permitted to issue the controlled SIOCTTLSCTL functions. 14 EFAULT All An incorrect storage address or length was specified. By submitting you agree to receive email from TechTarget and its partners. Please help as we are clueless and its happening our prod region Back to top kolusuSite AdminJoined: 26 Nov 2002Posts: 11548Topics: 74Location: San Jose Posted: Wed Mar 25, 2009 12:41 am

Ensure user ID has authority for the specified operation. 1015 EIBMBADCONNECTIONMATCH All A connection token that is not valid was detected. For socket write/send, peer has shut down one or both directions. This is not an error. Correct the name specified on the IDENT option TCPNAME field. 1012 EIBMBADREQUESTCODE All A request code that is not valid was detected.

Reconnect with the peer. 32 EPIPE IOCTL (SIOCTTLSCTL requesting TTLS_INIT_ CONNECTION, TTLS_RESET_CIPHER, or TTLS_STOP_ CONNECTION) The TCP connection is not in the established state. Following Share this item with your network: ERROR The requested URL could not be retrieved The following error was encountered while trying to retrieve the URL: http://0.0.0.9/ Connection to 0.0.0.9 failed. I did not move nothing to SOCKID, Is that correct? I try the connect again, in the same task, but the result was the same 1027 on return code.

It is highly recommended that you use EZASOKET. 5. Verify TCP/IP is active. 1014 EIBMUNAUTHORIZEDCALLER All An unauthorized caller specified an authorized keyword. Increase the number of allocate sockets, or decrease the number of sockets used by your program. 2009 ESOCKETNOTDEFINED REXX The socket is not defined. Call your system administrator. 73 ETIME All The timer has expired.

What release of MVS or z/OS are you running? Call your system administrator. 82 ENOLINK All The link has been severed. By submitting you agree to receive email from TechTarget and its partners. IF WS-RETCODE LESS THAN ZERO MOVE 'SELECT ERROR: WRITE ' to WS-ERR-MSG END-IF IF WS-EXCPTN-RTN-MASK GREATER THAN LOW-VALUES MOVE 'EXCPTN RTN MASK ERROR2' TO WS-ERR-MSG END-IF Sometimes we can see that

Correct the name specified in the IBM_TCPIMAGE structure. 1011 EIBMBADTCPNAME INITAPI A TCP/IP name that is not valid was detected.